Take a look at
/etc/svxlink/svxlink.conf
Below is my TX section info.

On 6/20/2024 7:49 PM, Box1600 wrote:
toggle quoted message
Show quoted text
It has nothing to do with the repeater, (which is an MTR-2000).
In testing the software we found that the GPIO output that
controls the PTT line never unkeys if the COS signal is held
active longer than the set timeout period.
Everything else seems to works as it should.
Thanks, I'll check out that SXVLINK group.
73 - BILL KA8VIT
Hello Bill,
With this being the
issue, it be helpful to know what you are using for a
repeater.
You may also want to
ask the question at the svxlink at groups.io?
/g/svxlink
Mick - W7CAT