Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- QRPLabs
- Messages
Search
Re: QMX - Any progress on key clicks please?
Looks like a lot of consistency in the settings being reported. Mine probably won't add much, but I promised to post them. I did try this in Practice mode, which I had not used before, and the clicks are the same as when producing RF.
Hoping for a solution! 73, Randy, KS4L |
Re: #qmx High Noise on all bands, screwy receive and bad diagnostics
#qmx
Thanks :)? Maybe I'll customize it with a stencil of a old style ship or something in the end, we'll see!? Digikey parts should arrive tomorrow according to Fedex, in theory, so I'll hopefully know soon.
|
Re: QMX - Any progress on key clicks please?
Chris,
I think it still comes back to volume level. I tried using my little amplified speaker and the clicks are gone - that is until you turn the volume up to really uncomfortable levels - then they are as bad as before. To put it another way, if you notice the clicks in the headphones, then change to amplified speaker, the clicks are still there.? -- 73, Dan? NM3A There are moments when everything turns out right .... Don't let them alarm you; they pass.? -Jules Renard |
Re: QMX - Any progress on key clicks please?
Chris,
?I tried your settings and there is no change. Unless... you turn the volume way down. Volume level is the only thing that seems to make a difference. Low volumes, I don't hear clicks. High volumes, it is awful. As I said before, at volume levels in a QSO with medium to strong stations, the clicks are minimal.? -- 73, Dan? NM3A There are moments when everything turns out right .... Don't let them alarm you; they pass.? -Jules Renard |
Re: QMX - Any progress on key clicks please?
I have to admit that I was a bit mystified as to how I managed to get the sidetone working perfectly as I initially played a lot with the settings to no avail and then the problem just seemed to disappear. I've just remembered that I had headphones connected to the audio jack when I first had the problem.? I just tried those same headphones again and the problem returns but when I connect the audio jack to the line-in on my PC soundcard it's perfect!? So It seems that input impedance of the headphones/speaker may be a factor here? |
Re: QDX - stops on 10m after a few seconds
On 13/03/2024 11:18, hamradio@... wrote:
For me it looks like QDX usb resets as soon as it starts transmitting.Torsten, RF getting into the USB cable? Try different cables, put chokes on cables. Or stop common-mode signals on the feeder. Reconfigure antenna. 72 Alan G4ZFQ |
Re: QMX - Any progress on key clicks please?
Hans - It looks like we have a real problem for many (most?) of us! Perhaps it is a bigger issue than we all realised. I welcome your comments please, meanwhile, back in the desk drawer it goes as, sadly, unusable.
Everyone - Thanks for posting your settings. Rather than reproduce my settings here, I will just say that I am using the same settings as Adrian YO3GFH, having copied them from an earlier thread. I have also tried disabling the AGC and copying Chris Bolton's settings - it makes no difference. Audio thumps exist after (not before) every dit and dah (whether at 2 wpm or 30 wpm.) Please can we fix this asap? Best wishes all, Daimon. G4USI |
QDX - stops on 10m after a few seconds
Hello there :)
I built a QDX (PCB Rev 5 and firmware 1_10) for 20, 17, 15, 12, 11 and 10m (12 volts version) that works well (rx & tx) on 15m, but fails running on 10m. The QDX is connected to a Debian Bookworm system. For me it looks like QDX usb resets as soon as it starts transmitting. /var/log/syslog right after booting the system: 024-03-13T07:28:21.281069+01:00 lab kernel: [ 1.404372] usb 1-4: New USB device found, idVendor=0483, idProduct=a34c, bcdDevice= 1.00 2024-03-13T07:28:21.281069+01:00 lab kernel: [ 1.404378] usb 1-4: New USB device strings: Mfr=1, Product=2, SerialNumber=0 2024-03-13T07:28:21.281073+01:00 lab kernel: [ 1.404379] usb 1-4: Product: QDX Transceiver 2024-03-13T07:28:21.281073+01:00 lab kernel: [ 1.404381] usb 1-4: Manufacturer: QRP Labs ... 024-03-13T07:28:21.281238+01:00 lab kernel: [ 2.636203] cdc_acm 1-4:1.0: ttyACM0: USB ACM device 2024-03-13T07:28:21.281242+01:00 lab kernel: [ 2.636255] usbcore: registered new interface driver cdc_acm 2024-03-13T07:28:21.281242+01:00 lab kernel: [ 2.636259] cdc_acm: USB Abstract Control Model driver for USB modems and ISDN adapters 7:40 torsten@lab:~$ sudo ls -l /dev/ttyAC* crw-rw---- 1 root dialout 166, 0 13. M?r 07:28 /dev/ttyACM0 07:41 torsten@lab:~$ WSJTX error-message: Hamlib error: write_block():1077 failed -1 - Input/output error ic10_transaction: called cmd='IF;', len=3, data=0x7ffa789f33d0, data_len=0x7ffa789f3384 rig_flush: called for serial device read_string_generic called, rxmax=4095 direct=1, expected_len=1 read_string_generic(): read failed, direct=1 - Input/output error tcflush write_block():1077 failed -1 - Input/output error ic10_transaction: called cmd='IF;', len=3, data=0x7ffa789f33d0, data_len=0x7ffa789f3384 rig_flush: called for serial device read_string_generic called, rxmax=4095 direct=1, expected_len=1 read_string_generic(): read failed, direct=1 - Input/output error tcflush write_block():1077 failed -1 - Input/output error IO error ) 1:rig_get_vfo: elapsed=1ms 1:rig.c(2991):rig_get_vfo returning(-6) IO error IO error IO error while getting current VFO /var/log/syslog after the error: 2024-03-13T07:17:23.028955+01:00 lab kernel: [41902.754569] usb usb1-port4: disabled by hub (EMI?), re-enabling... 2024-03-13T07:17:23.028974+01:00 lab kernel: [41902.754583] usb 1-4: USB disconnect, device number 2 2024-03-13T07:17:23.074877+01:00 lab kernel: [41902.804441] usb 1-4: cannot submit urb (err = -19) 2024-03-13T07:17:23.074926+01:00 lab kernel: [41902.804538] xhci_hcd 0000:00:14.0: WARN Event TRB for slot 1 ep 5 with no TDs queued? 2024-03-13T07:17:23.074929+01:00 lab kernel: [41902.804551] xhci_hcd 0000:00:14.0: WARN Event TRB for slot 1 ep 6 with no TDs queued? 2024-03-13T07:17:23.076888+01:00 lab kernel: [41902.804632] usb 1-4: Unable to submit urb #2: -19 at snd_usb_queue_pending_output_urbs 2024-03-13T07:17:23.076918+01:00 lab kernel: [41902.804800] usb 1-4: cannot submit urb 0, error -19: no device 2024-03-13T07:17:23.076921+01:00 lab kernel: [41902.804810] usb 1-4: cannot submit urb 0, error -19: no device 2024-03-13T07:17:23.079146+01:00 lab pulseaudio[1953]: Could not recover from POLLERR|POLLNVAL|POLLHUP and XRUN: Daten¨¹bergabe unterbrochen (broken pipe) 2024-03-13T07:17:23.083795+01:00 lab pulseaudio[1953]: Could not recover from POLLERR|POLLNVAL|POLLHUP and XRUN: Eingabe-/Ausgabefehler 2024-03-13T07:17:23.356935+01:00 lab kernel: [41903.082794] usb 1-4: new full-speed USB device number 4 using xhci_hcd 2024-03-13T07:17:23.504901+01:00 lab kernel: [41903.232739] usb 1-4: New USB device found, idVendor=0483, idProduct=a34c, bcdDevice= 1.00 2024-03-13T07:17:23.504930+01:00 lab kernel: [41903.232755] usb 1-4: New USB device strings: Mfr=1, Product=2, SerialNumber=0 2024-03-13T07:17:23.504933+01:00 lab kernel: [41903.232761] usb 1-4: Product: QDX Transceiver 2024-03-13T07:17:23.504934+01:00 lab kernel: [41903.232765] usb 1-4: Manufacturer: QRP Labs 2024-03-13T07:17:23.508949+01:00 lab kernel: [41903.235416] cdc_acm 1-4:1.0: ttyACM1: USB ACM device 2024-03-13T07:17:23.513661+01:00 lab mtp-probe: checking bus 1, device 4: "/sys/devices/pci0000:00/0000:00:14.0/usb1/1-4" 2024-03-13T07:17:23.513836+01:00 lab mtp-probe: bus: 1, device: 4 was not an MTP device 2024-03-13T07:17:23.546437+01:00 lab systemd[1936]: Reached target sound.target - Sound Card. 2024-03-13T07:17:23.546901+01:00 lab systemd[795]: Reached target sound.target - Sound Card. 2024-03-13T07:17:23.549359+01:00 lab mtp-probe: checking bus 1, device 4: "/sys/devices/pci0000:00/0000:00:14.0/usb1/1-4" 2024-03-13T07:17:23.549495+01:00 lab mtp-probe: bus: 1, device: 4 was not an MTP device As you can see the port changed from /dev/ttyACM0 to /dev/ttyACM1, and its not recognized correctly anymore. Also the "Soundcard"-devices aren't available anymore ... sometimes the input device "survived", but the output-device is gone each time. Any hints what to do/test? Cheers, Torsten -- vy 73 de Torsten | DO4TE /"\ ASCII Ribbon Campaign \ / Against HTML Mail ?X www.asciiribbon.org / \ |
Re: #qmx High Noise on all bands, screwy receive and bad diagnostics
#qmx
BTW Martin, I had a really good laugh at your Ship of Theseus reference. Clever! Let's hope that changing out that Stereo ADC will be the last of it. Looking forward to seeing your All OK message. JZ On Tue, Mar 12, 2024 at 5:19?AM Bruce Akhurst <bruce@...> wrote: Ps. If you have a VNA /antenna analyser that can be set to continuous mode you¡¯ve got a low power signal generator already? |
Re: QMX no Rx after a few days of operation
Got my QMX on Monday March 10th. Did 2 QSO's 20m.
CQ'ing again on tuesday - no rx at all. Transmit is fine to me. 1 - board revision: Rev3 so Hans told me - got it assembled from QRP-Labs and do not open it. 2 - Bands: low, 80-20 m 3 - build supply voltage: 12 V 4 - FW version: 1_00_017 5 - modifications: none I am slightly frustrated... cheers - Raimund |
to navigate to use esc to dismiss