Re: QCX high current first start up;


 

Thanks Alan. You are probably right. I tried that. The 12v line is not a dead short. It measures ~5K. Something is drawing current. The 7405 is putting out 5v.
John k1ym

Sent from my iPhone X

On Feb 5, 2018, at 2:57 AM, Alan G4ZFQ <alan4alan@...> wrote:

I am getting current drain of over 2 amps when I connect 12 v. I see that is not correct.
I noticed I had touched Q3 with my soldering iron during construction and it was slightly melted. I removed it but that was not the problem.
Anything else I can try?
John,

It seems likely that an ohmmeter will find a short circuit to ground on the 12V line.
Maybe a whisker of solder, look carefully.

73 Alan G4ZFQ