Re: QCX Toroid / Transformer Wire


 

The only real question is whether the necessary number of turns will
fit if you use the larger wire. Won't be a problem if you're building
for 20 meters or higher. Might be if you're doing a 40 meter build,
and even with the stock wire they don't fit if you're doing 80 meters.
Aside from that, it won't change the operation of the circuit enough
to matter.

On Wed, Dec 20, 2017 at 3:17 PM, ve7tk via Groups.Io
<ve7tk@...> wrote:
A group of us are beginning our efforts to construct the QCX CW transceiver.

We noted that the transformer wire size is specified (page 50) at #28
enamelled. The wire size for L1, L2, L3 and L4 is not specified.

In the unlikely possibility that we have a problem (ya right) could #26 wire
(I have a spool of #26 and #30 but no #28 - sigh) be substituted for the
transformer and/or windings?

Thanks,
--
73, Rick
VE7TK