Re: #qmx SSB Firmware beta 1_01_004 release #qmx


 

Hi Chris
?
Some phases stopped early
160m? 1100
80m? ?1300
60m? 2500
40m 2600
30m 2600?
20m 2500
17m 700
15m 700
12m 1500
10m 2300
6m 1200

My results here on a QMX+

160m: 2650
80m: 2650
60m: 2650
40m: 2650
30m: 2650
20m: 2650
17m: 1150, subsequent one-off tries 1200
15m: 1500
12m: 1350
11m: 1950
10m: 700, subsequent one-off tries: 1750, 1500, 1750
6m: 2650

None of these are classified as a "fail" by the calibration system, which would occur if they generate spurious nonsense wagging up and down all over the place. They are all reasonably clean curves until the point they suddenly stop.

73 Hans G0UPL