Re: QMX+ with 100 amp/hour lithium iron battery


 

The 78/79 hundred families of regulators expect bypassing on both input and output sides of the regulator.Look at the data sheet for recommended values. Typically, 3.3uf and 0.1 or 0.01uf on the output. Short lead lengths are also recommended. without these, stray inductance is going to cause the regulators to oscillate.
Rick K8BMA
?