Re: QMX+ points A continuity check to ground question


 

Hi Stan,
On p25 in section 2.8 of the rev 3 assembly manual, it clearly states “Check that there is NO DC continuity from the points marked A, and ground.” ?This would be after T501 is installed.
Thanks for the explanation of the mosfet protection diodes.?
I will have this board and T501 in hand on Thursday and hopefully figure out why we are seeing continuity to ground after T501 is installed, even though the windings on the uninstalled T501 show no continuity.?
73,
Steve AK0M
?
?