On Sat, Mar 22, 2025 at 06:53 AM, Hans Summers wrote:
You might try switching OFF the 80/20m BPF swap in the advanced configuration
Hans,
?
I have been having a similar issues on 20m. (20M to 10M QMX). When first running calibration, I used "R" run mode to do everything via the console.? On both 20m and 11m the Phase Error vs DAC plots finished very quickly and looked strange.? SSB effectively did not work and was just distortion on Tx.?? I re-ran BOTH Phase and USB for 20m using "O" once mode and while the Phase plot still looks strange it did change. Tx improved and I have been making contacts.?? The Phase plot changed when I ran it in "O" mode.?? Items to note:?
1) with 003 I used "R" run mode and was able to replicated the original problem with the plots on 20m and 11m.
2) this happens both when using the terminal via USB, and when just using the QMX menus disconnected from USB.
3) with 003 I can make SSB usable using "O" once mode for phase / USB / LSB calibration, but the plot is still strange: