Re: QMX triggers SWR protect into 50 ohm dummy load. #qmx


 

On Wed, Oct 2, 2024 at 05:02 AM, @Ludwig_DH8WN wrote:
I was under the impression that the BPF scan uses the same signal source that does the LPF scan (I could be wrong)
At least the same source but a very different way (see QMX Terminal Hardware Sweeps ).
?
Thank you, Ludwig, for the pointer to that description which I had not seen before.? It does confirm that the troubleshooting guidance I gave in my last post is correct: if the BPF scan gives proper results, then the LPF must be at least mostly working.? The main fault would need to be in the PA (via L502 & T501), or in the SWR detection/output (via T507 and surrounding components).

Join [email protected] to automatically receive all group messages.