Re: QDX and QMX+ (soon at least) what is the max safe swr?


 

Chris,

Long ago, on QDX, we learned that L14 was capable of producing very large Ldi/dt spikes when the current through it changed abruptly at the end of a transmission. A commutating diode across L14 was proposed to absorb the spikes.

In QMX the presence of an envelope modulator was thought to moot that problem by gracefully winding down the current in L502.

However, rapid changes in load can also cause Ldi/dt reaction at L502. Rapid relay switching of an ATU almost certainly can do that.

I believe that may be the source of the high voltage spikes you observe when allowing an ATU to seek a match.

JZ KJ4A?

On Mon, Sep 16, 2024, 6:30?PM Chris KB1NLW via <chrisrey1=[email protected]> wrote:
I'm doing a deep dive into cause of BS-170 failures.??
Currently I have finished evaluating peak BS-170 Drain to Source voltage and am in the middle of power dissipation for various SWRs.
  • On 160m and 80m Peak voltage exceeds the BS-170 60v spec.? Probably should not use at 12V operation, particularly at 160m
  • Using an Elecraft TI ATU there are spikes during tuning of over 100v!
I will am putting together a detail presentation.? Here are a couple of charts:
?
?