Re: Qmx in receiver mode tx voltage in red


 

G.,
One more thing...

If a short (e.g. solder bridge) exists between gate and L502, as was the case prior, it will read as a hard short gate-to-drain at Q507.?

You should check that as well before any attempt at surgery.

JZ

On Sat, Feb 24, 2024, 7:32?AM John Z via <jdzbrozek=[email protected]> wrote:
Giovanni,

Before you attempt removal, please post what readings you obtained. Remember, there are other circuit elements present that must be considered.

JZ

On Sat, Feb 24, 2024, 7:29?AM Giovanni Ilari IT9XJJ <giov.ilari@...> wrote:
Yes! Q507 shorted! Measured drain and source and also shorted with gate! Vy difficult desolder! I have not hot air desolder, is there a fast solution??

Join [email protected] to automatically receive all group messages.