¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: IQ Output Question


 

On Mon, Feb 12, 2024 at 08:12 PM, Jim Bennett / K7TXA wrote:
Hans - I did a factory reset twice. No Joy. Some testing revealed something very strange.

?I enter the Digi interface screen and turn the right encoder through the eight entries, without changing any of the values, each of the eight values do not change while IQ mode is sitting at DISABLED.

?With IQ mode still DISABLED, I can change any of the other seven values, rotate the right encoder and they all stay as I've set them.

?However, if I change IQ mode to ENABLE, then rotate the right encoder through the eight entries, I find that two of them have changed: IQ mode is now DISABLED and Minimum cycles now has a random number as its value. None of the other values have changed, only those two. I get the exact same behavior if I change IQ mode to?ENABLE?and simply press the right BUTTON twice to get back to frequency display. I can then go back to the Digi interface entries and find those same two fields changed once again: IQ mode DISABLED and another random number in the Minimum Cycles field. ?I also fired up PuTTY and all tests are green.

?This is 100% repeatable. So - what the heck is happening here?
--
Jim / K7TXA
Eagle, ID

SKCC 10447C
BUG 301
Jim,
I confirm that I can reproduce on my QMX the behaviour you're describing. I have always enabled IQ mode from the System config menu, and it worked properly that way.
REv. 2 board here.

Regards,
YO3GFH
op. Adrian