Re: QDX - protection of BS17O PA


 

Hi Willie

There was the load mismatch. And the spike on QDX key-up. But for now I reckon I spend enough time in Ghostbusters mode last Friday ;-/

73 Hans G0UPL


On Tue, Sep 19, 2023, 9:16 PM William Smith <w_smith@...> wrote:
Personally, I would rather someone else did this experiment, and Hans was allowed to get on with his to do list. ??¡á?

73, Willie N1JBJ

On Sep 19, 2023, at 1:03 PM, Ryuji Suzuki AB1WX <ab1wx@...> wrote:

?

On Tue, Sep 19, 2023 at 12:39 PM, Gary W9TD wrote:

Otherwise, how would you know if you have picked the "toughest" load?

You can fine tune the simulated load to any precision you want, but we know the toughest load can increase the drain voltage peak to about 2x the normal baseline with a matched load. (The normal baseline voltage is already significantly higher with class C/D/E amps compared to class AB of the same supply rail voltage, so that's a double whammy to BS170s.)

After all, all these come down to a question of how to allocate safety margins and how to prevent exceeding the limits. The limits are largely known. We were discussing how that could be reasonably seen on bench.

Join [email protected] to automatically receive all group messages.