On Wed, Nov 6, 2024 at 08:21 PM, Jerry Lee Marcel wrote:
This seems correct.
What about when the mic doesn't work?
Hi Jerry. Here are the results from today but I'm not sure if I was fast enough to measure all points before the mic started working. At some points I had to wait until the value on the scale settled. I'll try again tomorrow.
?
A=6.58
B=8.42
C=1.30
D=0.63
E=8.24
F=16.32
?