Re: Upload from PC to Gemini
Russ, this has nothing to do with update, but a setting you've changed in the ASCOM driver. Is this the message you're talking about? This is asked when you turn on the update advanced settings from
By
Paul Kanevsky
·
#82110
·
|
Re: Upload from PC to Gemini
Are you talking about the "Set Gemini Time on Connect" or "Set Gemini Site on connect on the ASCOM "Configure Telescope" page? Or the "Send Advanced Settings to Gemini on Connect" box on the ASCOM
By
Ryan Noonan
·
#82109
·
|
Upload from PC to Gemini
Ever since my upgrade, I've been getting this message about uploading PC data to Gemini.? I accidentally selected ok tonight and now it is updating slowly (about 10 minutes) elapsed so far and not
By
Russ
·
#82108
·
|
Re: Warm RA Motor
Apparently, it was tracking with intermittent RA Stalling. I thought an RA Stall stops the motors. I had adjusted the worm gear a few days ago so I am surprised it tightened up so soon.
By
peter@...
·
#82107
·
|
Re: Warm RA Motor
It is a DC Servo motor. They get warm under use. This is typical of all DC servo motors. Generally speaking a servo motor will not be damaged unless internal temperature is higher than 130C and outer
By
Ryan Noonan
·
#82106
·
|
Warm RA Motor
Is a warm RA motor normal. I have never noticed this before. I have a 10 month old G11G.
By
peter@...
·
#82105
·
|
Re: Dual-axis controllers EPROM images
Thanks!!!! david.partridge@...> wrote:
By
Christopher Erickson
·
#82104
·
|
Re: C11 users....what photographic results are you getting?
I did get about an hour of messing around again last night before some unexpected clouds came in.? I was able to adjust the guide settings in the ASI air and get the RMS down from about 2 to about
By
BBasiaga
·
#82103
·
|
Re: Dual-axis controllers EPROM images
I have sent the firmware images to Christopher David Sent: 25 February 2024 04:54 To: [email protected] Subject: [Losmandy_users_io] Dual-axis controllers EPROM images Would anyone here happen
By
David C. Partridge
·
#82102
·
|
Re: 811G lack of DEC dampening options!
Loren, Are you saying the target in the eyepiece is oscillating back and forth as you look through it, or just a
By
John Kmetz
·
#82101
·
|
Dual-axis controllers EPROM images
Would anyone here happen to have copies of the firmware binary or hex code for the EPROM's for the Losmandy dual-axis controllers? Also it is my understanding that the EPROM code for the GM-8
By
Christopher Erickson
·
#82100
·
|
Re: 811G lack of DEC dampening options!
Check the two Azimuth bolts and the Altitude bolt on the mount.. They may have been loose when you received the mount assuming you would tighten them when you polar align.. And make sure the scope is
By
Derek C Breit
·
#82099
·
|
Re: 811G lack of DEC dampening options!
Hey there Loren, That does help me understand a bit more; thank you. My only additional question: Have you tried adjusting the worm block position to fit snugly on either side of the worm gear yet? or
By
Ryan Noonan
·
#82098
·
|
Re: 811G lack of DEC dampening options!
Ryan The term "springy oscillation" describes what I see when mainly centering the scope for visual use i.e. repetitive image movement with a period of maybe less than 1/2 second. I've observed really
By
lorentoole@...
·
#82097
·
|
Re: 811G lack of DEC dampening options!
Hey Loren I¡¯m looking for further clarification if the term ¡°springy oscillations¡± For perspective, it is difficult to troubleshoot a system with verbal descriptions that don¡¯t match a
By
Ryan Noonan
·
#82096
·
|
Re: 811G lack of DEC dampening options!
I bought a G11G last spring and thought the idea of a spring-loaded worm gear was great, as it was, my EQ6-R Pro didn't have this. I hadn't got to the point where I would see any apparent improvement
By
peter@...
·
#82095
·
|
811G lack of DEC dampening options!
I'm a new 811G owner, as of November 2023. I received the mount from Losmandy with all of the newest features: spring-loaded worm, tucked motors, Gemini 2 updates, hand-tuned by Scott. At the moment I
By
lorentoole@...
·
#82094
·
|
Re: C11 users....what photographic results are you getting?
The "nut" is part of the knob. What is needed is an axial anti-backlash nut for the focuser's threaded rod. IIRC they are 0.25" 28 TPI. Here's a commercial nut. Essentially two nuts connected by a
By
George Cushing
·
#82093
·
|
Re: C11 users....what photographic results are you getting?
The Meade 12" SCT is about the same weight as a C14. A Meade 2120 is about the same weight as a C11, which isn't that much heavier than the C9.25. The original G11 was a modification of the Losmandy
By
George Cushing
·
#82092
·
|
Re: C11 users....what photographic results are you getting?
There are no mirror locks on a standard C11, at least not my 2006 edition.? ?Wisdom on the imaging forums is that in that case it is best to use the mirror to focus, finishing CCW to ensure
By
BBasiaga
·