Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
On Sun, Aug 8, 2021 at 08:25 AM, Paul Kanevsky wrote:
Paul thanks, So why the sudden change? First image stars are great. Slew to a target at low altitude and 150 rotated, then come back to same target and suddenly the stars are drifting north. Could my clutch be slipping? Peter |
Need your help: table of terms and abbreviations
Hi Folks,
I've created a new table for this group that is meant to contain short descriptions and definitions of obscure terms and abbreviations. The table is editable by all members, and I invite everybody to add to it. The table is located here (in the Databases section of this group):? /g/Losmandy_users/table?id=33190 The goal is to help new users and those who may not be familiar with Losmandy mounts or related software to quickly decipher some of the messages being posted here. I started the list by copying some of the definitions from gemini-2.com website, but would love to see others add and expand the list over time.?? Please contribute! Here are some examples from the table: Regards, ? ? ? -Paul |
Re: Other possibility for oblong stars
Undersampled guiding can certainly result in worse tracking performance. Usually it will not result in a continuous star drift on the main imager but can result in bloated stars and sometimes, elongated ones. Another possible source of star drift is guiding on a hot pixel.
toggle quoted message
Show quoted text
Regards, ? ? -Paul On Sun, Aug 8, 2021 at 11:52 AM, wa1vta01452 wrote: I live in the northeastern US and am a G11 owner. ...I image with a 1000mm f/l scope and use 400mm for tracking, with a? ratio of 2.5, typically getting RMS values under 0.5 and with good seeing, under .45 in PHD2 .? Last fall I attempted to use a? 180mm? guide scope for tracking with a ratio over 5.5 and I consistently got oblong stars even on the most stable atmosphere nights. I switched back to the 400 and all is well again. |
Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
¿ªÔÆÌåÓýOne more question: Is the guide star somewhere in this field of view of the main camera?? -Les
|
Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
¿ªÔÆÌåÓýThose are some serious star trails. Are those star trails north-south, or east-west? ?That is, is it trailing in declination or in RA? How good is the DEC balance? ?With the clutch loose, and the counterweight bar ~horizontal, will the scope stay in whatever position you put? Not just horizontal, but vertical or at an angle ¡ª if not, can you rotate the tube so that it will stay put? ?If it is well balanced, then the mount won¡¯t know what declination you have it aimed at and the problem must be on the scope itself. ? -Les
|
Other possibility for oblong stars
wa1vta01452
I live in the northeastern US and am a G11 owner. ...I image with a 1000mm f/l scope and use 400mm for tracking, with a? ratio of 2.5, typically getting RMS values under 0.5 and with good seeing, under .45 in PHD2 .? Last fall I attempted to use a? 180mm? guide scope for tracking with a ratio over 5.5 and I consistently got oblong stars even on the most stable atmosphere nights. I switched back to the 400 and all is well again.
Tom |
Re: Gemini-2 momentarily went haywire
Very good thinking, Les! I will see if the PC DEC slew works properly.?? Best, Michael On Sun, Aug 8, 2021, 7:52 AM Les Niles <les@...> wrote:
|
Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
On Sun, Aug 8, 2021 at 09:17 AM, <pcboreland@...> wrote:
The second image shows what I got. I do not thing this is differential flexure?? Why not, Peter? If your guide scope guiding is not showing any large errors and the main imager shows constant drift, this is most likely differential flexure. Other possibilities include differential refraction at low altitudes and image rotation due to polar misalignment. There aren¡¯t too many other possibilities. Regards, |
Re: Gemini-2 momentarily went haywire
¿ªÔÆÌåÓýOoops this is a G2 ¨C in which case a burnt out motor control PIC. ? From: David C. Partridge <david.partridge@...>
Sent: 08 August 2021 16:23 To: '[email protected]' <[email protected]> Subject: RE: [Losmandy_users_io] Gemini-2 momentarily went haywire ? Most likely a burnt out PAL decoder for the Dec? channel ¨C you need to program it of course. ? From: [email protected] <[email protected]> On Behalf Of Michael Herman ? Hi gang! ? I received John's questionable G2 mini board, to test it out.?? ? Symptoms: ? It boots up fine. ? It slews to an Align Bright Star target fine. ? If you press the RA diamond East West button it slews RA fine. ? If you let it run Sidereal rate it tracks fine. ? If you press the DEC diamond East West button, the DEC motor runs away!? ? This is repeatable. ? John got a new board from.the factory and his system is fixed...it is definitely a problem with this board, not the cables, motors or handset.?? ? I'm unsure what to do to try and repair this board...John did try to resolder his DEC socket.?? ? Any suggestions from the above clues? ? Very best, Michael ? ? ? ? ? On Sun, Aug 8, 2021, 7:14 AM Brendan Smith <brenatlilydale@...> wrote:
|
Re: Gemini-2 momentarily went haywire
¿ªÔÆÌåÓýMost likely a burnt out PAL decoder for the Dec? channel ¨C you need to program it of course. ? From: [email protected] <[email protected]> On Behalf Of Michael Herman ? Hi gang! ? I received John's questionable G2 mini board, to test it out.?? ? Symptoms: ? It boots up fine. ? It slews to an Align Bright Star target fine. ? If you press the RA diamond East West button it slews RA fine. ? If you let it run Sidereal rate it tracks fine. ? If you press the DEC diamond East West button, the DEC motor runs away!? ? This is repeatable. ? John got a new board from.the factory and his system is fixed...it is definitely a problem with this board, not the cables, motors or handset.?? ? I'm unsure what to do to try and repair this board...John did try to resolder his DEC socket.?? ? Any suggestions from the above clues? ? Very best, Michael ? ? ? ? ? On Sun, Aug 8, 2021, 7:14 AM Brendan Smith <brenatlilydale@...> wrote:
|
Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
Hi David, You adjust the back off bolt so that the worm friction drops to it's minimum.? That is,? you want the worm to just lose contact with the worm wheel gear it is driving.?? If you are adjusting the RA, you also should try hanging a weight of a few pounds hanging to the East of the RA axis.? This direction of weight torque minimizes any "chatter" in the worm wheel disk that would appear as tracking noise.?? Best of luck, Michael On Sun, Aug 8, 2021, 7:50 AM David Malanick <malanick@...> wrote: Just one more little thing. Before I even touched my mount, I made sure I had a complete understanding of what the factory settings were. |
Re: Gemini-2 momentarily went haywire
¿ªÔÆÌåÓýThe next obvious guess would be resoldering the hand controller socket. Then start tracing the HC signals to look for something gone wrong. This would be easiest if you have a good board to do an A/B comparison.?The fact that a bright star slew works makes it seem like a controller input problem rather than a motor/encoder problem. What happens if you initiate a dec movement through the driver or web interface? ??-Les On Aug 8, 2021, at 7:24 AM, Michael Herman <mherman346@...> wrote:
|
Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
Just one more little thing. Before I even touched my mount, I made sure I had a complete understanding of what the factory settings were.
I wanted to make sure I had a reference point to refer to when doing any adjustments or modifications. I believe this to be very important when working on a mount like this that has so many different adjustments and modifications available. It adds quite a bit of time to find the right settings, and it cuts into your imaging time, but I believe it works out in the long term. When changing too many things at one time you can really get this mount out of whack. Here's just a quick reference picture of how I have mine currently set up. Once I get the basic things set up, I only have to touch one thing at a time in the field if needed. Makes it easier to find out if I have to go back to the start and retry something else. I keep my worm spring at 8.5 mm, as recommended by Brian, and that seems to be the correct setting. When I went by the video on how to set your spring-loaded worm, I believe the RA was around there but the DEC was way off. It was not 8.5 from the factory. So now I just keep it at 8.5mm with blue Loctite. However, I'm still wondering about the setting of back off screw. When you're turning the gears, do you stop the back off screw when the gear is just start to get tighter or when they get tight. There such a fine line in that setting. |
Re: 76sec error on new OPW-11
I have seen the new "milled down" (front or back full side) with the milled down bottom stud (aka "nipple") only on new SLW (spring loaded worm) drives.? Earlier wirm blocks were completely black anodized, inside and out.?? The new very thick aluminum of the SLW OPW metal channel (which has provision for the SLW spring attachment) requires the slightly smaller blocks to fit it's tight channel, and even so, it is very close to not closing the worm to ring gear spacing tightly.? ( I had to work on that RA to get the RA hysteresis to zero on Vishal's SLW system last week.? ) ? If you are ordering new replacement worm blocks, you'd really need to specify which blocks (or better which drive system) you have.? The website order form should break these different block types out. Best of luck, Michael On Sun, Aug 8, 2021, 7:30 AM David Malanick <malanick@...> wrote: The blocks evidently have changed. |
Re: 76sec error on new OPW-11
The blocks evidently have changed.
This must be due to the change over to the spring-loaded worm. I ordered a set of extra blocks when I did the Belleville washer modification, in case I needed them because of a screw up. You can see in the picture, the blocks I ordered are completely anodized and the index peg on the right is not milled down. The blocks that came with my mount, new in May, are milled down on one side. I assume this is to seat them tighter against the block holder. The block on the right that pivots up and down away from the worm has the index peg milled down. I assume this is because it needs more clearance room for pivoting as the worm rides up and down on the worm because of spring loading. |
Re: Gemini-2 momentarily went haywire
Hi gang! I received John's questionable G2 mini board, to test it out.?? Symptoms: It boots up fine. It slews to an Align Bright Star target fine. If you press the RA diamond East West button it slews RA fine. If you let it run Sidereal rate it tracks fine. If you press the DEC diamond East West button, the DEC motor runs away!? This is repeatable. John got a new board from.the factory and his system is fixed...it is definitely a problem with this board, not the cables, motors or handset.?? I'm unsure what to do to try and repair this board...John did try to resolder his DEC socket.?? Any suggestions from the above clues? Very best, Michael On Sun, Aug 8, 2021, 7:14 AM Brendan Smith <brenatlilydale@...> wrote:
|
Re: Gemini-2 momentarily went haywire
Was the board repaired at Losmandy? ?From experience a runaway flew is a bad motor socket solder join.?
|
Re: Things noticed with my G11G regarding recent topics including shaft wear, bearings, worms and miscellaneous
Here is a run down on the problem.
1. It occurred after changing out the Ra axis thrust bearings. 2. Polar alignment is via Sharpcap and was bang on at CDW. Just installed the NINA 3-point polar alignment plugin and at Michaels suggestion I will be able to double check polar alignment after slew to target to see if something has moved. 3. Target is 25 degrees altitude due south. Not a region of the shy I typically shoot, so problem could have existed before the Ra upgrade work and I would not know. My location is NJ. 4. As a test I decided to shoot the cave nebula which follows the typical trajectory of object I shoot. The first image shows the result of slewing to the target and taking a 400s image. 5. I slewed to the 2nd target due? south at 25 degrees lat and got terrible guiding results and could not get any data even at 60s exposure, so I slewed back to the cave nebula and resumed imaging. The second image shows what I got. I do not thing this is differential flexure?? 6. I've taken the following steps to run down this problem. A. Cleaned the Ra clutch disc? with lacquer thinner. These are Michaels clutch disc not Losmandy.? At Michaels suggestion I will install my OAG setup and retest. Peter |