Re: Unable to fully tighten dec axis on GM811G

 

Hi Glenn

Is it possible for you to post a video of what you see?

Depending on what you see, you might be talking about two different things

If it's actually the clutch, you may have oil or grease on the clutch pad

If it's the spring-loaded worm, it could just be the spring-loaded worm mechanism moving (although i'm not sure how you could show 1/4" movement there)

is it possible you are grabbing the end of the counterweight shaft and moving it back and forth??



On Sun, Apr 4, 2021 at 9:48 AM Glenn <glancey3@...> wrote:
I am unable to fully tighten the dec axis clutch on my GM811G. There's a quarter-inch play in either direction when the clutch is tightened down. Does anyone have a similar problem and is there a fix?



--
Brian?



Brian Valente
portfolio


Unable to fully tighten dec axis on GM811G

 

I am unable to fully tighten the dec axis clutch on my GM811G. There's a quarter-inch play in either direction when the clutch is tightened down. Does anyone have a similar problem and is there a fix?


Re: Duda sobre g11.

 

La G11T es una opcion real no cabe duda que ella si lo podria soportar con eficacia. Cierto es que el telescopio, mas guia y camaras se va de peso para fotografia. Es complicado elegir la montura, lo que tengo claro es que sera losmandy. Lo consulto con la almohada pero no me responde nada claro.


Re: Manual for the on 492 Digital Drive controller?

 

David, et al,

I share your preference for PDF.

But for future reference, it is easy to capture the HTML by copying and pasting into Word (or just about any text editor).

You can then save as a PDF or Word (amongst others) format. Plus in Word you can annotate the material if you wish.

No need to scan, and the result will usually be more compact and can be annotated.

Best regards,

Mark Christensen


Re: Manual for the on 492 Digital Drive controller?

 

¿ªÔÆÌåÓý

Paul, Yes that does it, thank you ¨C however a very kind soul sent me a scan of the original Celestron CG11 manual (I prefer PDF on my local machine to html ¡­

?

Thanks again Yamada San for the scan.

?

David

?

From: [email protected] <[email protected]> On Behalf Of Paul Homer
Sent: 04 April 2021 11:27
To: [email protected]
Subject: Re: [Losmandy_users_io] Manual for the on 492 Digital Drive controller?

?

David,

?

What you need is the G11 Equatorial Manual pdf on this page.

?

?

Paul

?

?



On 4 Apr 2021, at 7:10:18 pm, David C. Partridge <david.partridge@...> wrote:

?

Has anyone got a scan of this?

Thanks,
David





?


Re: Spikes!

 

¿ªÔÆÌåÓý

Hi!

Maybe, just maybe, you have the same spikes as I have, Jamie. See the attached guide-log. First run is interestingly enough without spikes, 2nd and 3rd have spikes, all in the same direction (I still have no clue about how to be sure which direction this is....) - and all RA spikes seems to happen when given a small guide pulse in the direction of the spike.

4th run same pattern + some DEC + RA spikes. In these, the RA spike is not simultaneous to a pulse guide. Since these are in both RA and DEC, I guess this is something different. So I do not focus on them now.

So my thinking: the RA-only spikes, seemingly triggered by a guide pulse, could depend on RA backlash and the scope too well balanced - so the small guide pulse sends the scope off an unproportional distance, so to speak across the backlash. Does that seem reasonable? It can be tested by Michael's suggestion of hanging an extra weight on the eastern side and see what happens. Need to wait for clear skies and then try (too bad this can not be tried during the day, and when cloudy).

I'm guiding with a 600 mm guidescope with a Lodestar, piggybacked on a C11, on a G11 with untucked motors, OPW and high precision worm. I have PEC enabled (have tested on and off, seems not to affect these spikes now).

When I run PemPro of guiding assistant in PHD2, there is a very smooth curve and no spikes like this. Which I think would rule out anything like dirt in the needle-bearings or on the worm, etc. These spikes seems only to occur when actively guiding. Again: makes sense?

Maybe this resonates with your situation, Jamie?


Magnus


Den 2021-04-03 kl. 16:13, skrev Jamie Amendolagine:

Well, had it setup with new calibration using the guide scope. Guiding started, and. Drumroll..... The clouds rolled in. Boop hiss's. I'll have to try when it clears up.?


Re: Manual for the on 492 Digital Drive controller?

 

¿ªÔÆÌåÓý

David,

What you need is the G11 Equatorial Manual pdf on this page.


Paul




On 4 Apr 2021, at 7:10:18 pm, David C. Partridge <david.partridge@...> wrote:

Has anyone got a scan of this?

Thanks,
David








Manual for the on 492 Digital Drive controller?

 

Has anyone got a scan of this?

Thanks,
David


Re: More looking at brass reactions to CRC MolyD lube

 

Good to know, Michael. The brass worms may wear over time, as they are softer than the ring gears, but at least they won't be corroding as well:).

My original RA brass worm seems to have an slight indentation where it meets the ring, but the threads have been worn smooth which is what we all want. I am wondering how many thousands of hours we can get out of one, before metal loss might be a problem. At least we know we can replace them when the time comes.


Re: Duda sobre g11.

 

Hello David,

You have a pretty big telescope and you must be an astrophotographer considering the specifications. As Brendan said, after adding accessories, you are getting pretty heavy, and might be getting close to the maximum capacity of the G11G. But it should still work out for you.

But if you can afford it, the G11T might be a better choice for you with the larger weight capacity. And with the Titan, you have more room for additional items like a larger guide scope, bigger camera, and any piggyback secondary telescopes too.?

Best Regards,

John


Re: Scope Location and NINA

 

Keith, I think the discussion was regarding time and latitude/longitude settings. These can be set from the driver. Custom site can also be selected from the driver. Either one can be set to update automatically, when the driver connects to the mount.

Regards,

? ? ? -Paul


On Sat, Apr 3, 2021 at 12:15 PM, Keith wrote:
Note that as per the Gemini.net documentation, one can't configure site info in the driver:

"Note: It is not possible to configure the preprogrammed sites via the driver; this must be done via the physical Gemini hand box (Gemini-1) and using the Web interface for the Gemini-2 and Gemini-2 Mini."

Keith


Re: Duda sobre g11.

 

On Sun, Apr 4, 2021 at 09:00 AM, Davidspain wrote:
Hola, tengo un newton 300mm f/4 y queria preguntar si la G11G lo soportaria adecuadamente, pesa 24 kg el telescopio.?
Hola David, el g11g tiene una capacidad de 27 kg, pero debes tener en cuenta los extras como la c¨¢mara, el visor de gu¨ªa, etc.



Un Newtonion de 300 mm dar¨¢ mucha flexibilidad diferencial

Sorry....google translate. ;)
--
Brendan


Duda sobre g11.

 

Hola, tengo un newton 300mm f/4 y queria preguntar si la G11G lo soportaria adecuadamente, pesa 24 kg el telescopio.?


Re: More looking at brass reactions to CRC MolyD lube

 

Hi Keith,

I'm not an AP owner ... so my info on this subject comes 2nd hand.? If you are in that forum you may have a better finger on the pulse of this riddle.??

My research on this topic showed some strong concerns by a website catering to old industrial machines (lathes, motors, where things get very hot) that were concerned about MolyD lubes deteriorating "brass" components.? Yet the McMaster-Carr company website highly recommends MolyD lubes for all metals.? It is a puzzle....is this a serious concern or a chicken-little story???

My friends, either profs who teach materials science, or head metallurgy industrial departments, were also concerned about sulphur reacting with brass (any copper alloys).? That in theory could be a corrosion concern.? But no one knows the kinetics or time dependence at room temperature, so I started a simple reaction test to see for myself.? So far...nothing is happening and I'm still exposing my test strip.? If this were a test on lemon juice I think I'd see a reaction already.? Of course all copper alloys deteriorate in air through oxidation, slowly, as the copper goes through its oxidation states Cu2O, CuO, CuO2.??

However, the MolyD in the CRC grease is diluted and anyway is not pure sulfur. The sulfur in bound up in the slippery crystal mineral crystal MoS2.? The reason that is a lubricant is that the flat layers of MoS2 slide on each other....like why graphite is slippery.??

That's why modern expensive gasolines are low sulfur too... when they burn in a car engine, the combined sulfur and water form a sulfuric acid that eats away at metals. (and pre 2001 Jaguar engines had a "Nikisil " high strength coating from BMW motorcycles...and high sulfur gasolinesxin Europe ate that coating away...bye bye engine cylinders.? US gasolines don't have the sulfur so they don't get this problem...)

It's also why I like astronomy as a hobby.? It has so many challenges!!!? (Fred the expert punster would tell me it's a slippery subject.)

All the best,
Michael


On Sat, Apr 3, 2021 at 9:12 AM Keith <keithdnak@...> wrote:
Perhaps it's worth asking Roland in the AP forum as to from where his recommendation stems - surely he must have done some experimentation or has seen evidence of this?

Keith




Re: Yup its the 75 second cycle

 
Edited

Henk,

The bearings are pretty inexpensive, about $10 (US). Since the 76 second error is related to the bearings, new will be best. Old bearings could have wear spots or may have been slightly warped during original installation or removal. If the block seats were too tight, or changed with temperature (as per Michael's explanation), the outer races could be slightly out of round, or bent. This may cause the ball hang ups, as per the white paper. So the same bearings may retain their deformations, even after you change the seating or springs tensions.

As per Michael's advice, it seems the right bearing is the one to float, to allow Belville washer tension, but also to permit some slight flex along the worm axis. The left one should remain as the solid base. I suppose that seating could be loosened as well to prevent some crushing, but I have not heard much discussion about that. But installation of the left is still critical, being careful to evenly tap into place without pinching, so tap or push slightly around the edges gently to wiggle into place.?

I have followed Michael's instructions, and read the whitepaper and discussions, so I am following the instructions of those experts. Figuring this out on one's own would take a quite a bit of study and research. Good luck.

Regards,

John


Re: Scope Location and NINA

Keith
 

Note that as per the Gemini.net documentation, one can't configure site info in the driver:

"Note: It is not possible to configure the preprogrammed sites via the driver; this must be done via the physical Gemini hand box (Gemini-1) and using the Web interface for the Gemini-2 and Gemini-2 Mini."

Keith


Re: More looking at brass reactions to CRC MolyD lube

Keith
 

Perhaps it's worth asking Roland in the AP forum as to from where his recommendation stems - surely he must have done some experimentation or has seen evidence of this?

Keith


Re: Yup its the 75 second cycle

 

Nice work, gang!

Henk has got a really good system to investigate.? That is, he can clearly see the RA periods and therefore his experiments to reduce them are possible.? When he finds a solution (hoping for his success, as Alan reported the 76 second oscillation teduction seems linked to reworking the "far" bearing (away from.the gearbox) OD size and seating in a thin Belleville spring washer).??

At least, that's what Alan and I did on his new SLW system.? We did not try polishing the ID of the block.? Here's one reason why: if you were to overpolish the block you can't go back.? New blocks are $35 from Losmandy.? New ABEC-7 R4ZZ bearings are ~$11 each from
Specifically this one I use with "Kyodo grease":
?

I think that polishing the OD of the bearing by hand is easy to do and if you mess up, you can easily create another polished bearing for low cost.? You have not messed with the stock bearing block.??

Henk asked if putting in a 2nd Belleville under the "near" bearing (nearest the gearbox) would be better or could be done.? I encourage you to try it and tell us if it helped.??

I will say that my experiments on putting a 2nd Belleville {face to face I tried to put 2 under the far worm block like this: )(? }...did not work. The reason is that the slight extra Belleville thickness, that must push outward the far worm block slightly, took up the room in the far mounting hole needed to push the far block worm sufficiently inward toward the ring gear.? But...your mount might have more room than mine did.??

Stuart Hutchins, a very experienced and knowledgeable group member, has been explaining the details of bearing seals, concerns about polishing dist entry, and precision belt drives to me. He just suggested that you could mount the R4 bearing between a pair of R4 Belleville spring washers to compress and hold the bearing on a 1/4 inch precise mandrill, then use like a drill to precisely spin the bearing...and some fine sandpaper to buff down the bearing OD more consistently.? I have not tried this nice idea yet.? He was concerned that the polished bearing OD needed to be precisely round, but since the OD of the bearing merely needs to slide, not rotate, I don't feel that level of roundness perfection is necessary.? The inner races must be precisely round as they must roll without "rumble" which is why I prefer the highest ABEC quality...but even so I get extra bearings and feel them for smoothness.??

I was also going to say "don't blame everything in PE on the worm!" If you have an Oldham coupler, the movement of the sliding center plastic piece also can introduce a periodic error if the two ends have an angle between their axes.? There are other couplers but I could not fit them into the available space.? Some people with lathes can reduce the OD of the larger couplers, and have tried...maybe they can say if this improved their PE.?

Wishing you the best of luck on your pursuits,

Michael





On Sat, Apr 3, 2021, 2:57 AM Ian Taylor <robert.ian.taylor@...> wrote:
Hello Henk, the high precision worm should give a periodic error of about +/-5¡± so it all looks ok to me (and the period would be 239 seconds). I found misalignment of motor and worm could give extra harmonics (and this would include any bearing misalignment), so I would also check if everything is aligned well. To get lower values you would need to use PEC. Don¡¯t know what focal length you are imaging at but autoguiding should work well with that level of periodic error.


Re: Yup its the 75 second cycle

 

There is actually another option, namely to stack every 10 seconds and use no PEC or autoguiding at all.? That way the errors will never exceed the errors in a 10 second interval.? The technology is available, I know someone who does this with his ATIK.? Perhaps the live stacking of Sharpcap can do this for general cameras.? If not now, some time in the near future.? The computing power should be there already, it is just a matter of time until people start wanting this feature.


Re: Yup its the 75 second cycle

 

Thanks Ian, that's good to know.? I think the inner block was misaligned because I had to make the flex couplers of my stepper fit, and those have some stiffness while the motor and worm were not perfectly aligned also.? Let me see if I can do a better job at that.??

Maybe an autoguider can handle it but I started looking into it because I get over 1" RMS and I expect this mount to do better.?

I added the spring loading because the mount had more backlash than I liked.? Tightening the worm would simply lead to the mount binding up, I could feel it manually.? The ring gear is just not round enough to have zero backlash.? Looking at the first graph (spring loaded configuration), it doesn't look much better than the second but at least it keeps the mount from binding up when slewing.

So I can pick my poison.? I can align the blocks as best as I can, tighten them, abandon the spring loading, allow backlash (hardly a problem for RA when tracking) and put up with the 240 second cycle and the backlash for slewing and plate solving.? Or I can keep the spring loading, improve it so the 75 second cycle is more regular than what we see in graph 1, and put up with the 75 second cycle.? Or I can drill out the holes in the blocks, apply Belleville washers and spring loading.? Let me try the non destructive options first.?