Re: G11G Imaging Weight Capacity for Imaging?
At one time I used Blue Loctite on the grub screws and quickly regretted it.? It wicked onto the shafts.? It took me an entire weekend to clean stuff up.?
?
Several years ago I replaced the grub screws on the two aluminum 1-to-1 transfer gears with 4-40 x 1/4 cap screws. Theses work much better than the original grub screws but occasionally they work loose too.?
------------------------ Jim W Phoenix, AZ. USA
Losmandy G11G w/ L6, NINA 3.0 / ASTAP, ASI2600MC Pro, Sky-Watcher Scopes, Canon L Lenses.
|
Re: Did my Gemeni 2 firmware become corrupt?
Are you all good to go again?
|
Re: G11G Imaging Weight Capacity for Imaging?
On Mon, Feb 10, 2025 at 12:48 PM, Jim Waters wrote:
Francisco
?
With any luck it will be clear enough tonight to do a PHD2 guiding run.? I adjusted the RA worm to ring gear spacing and I want to make sure I didn't mess things up.? I also found some loose grub screws.? I will contact you Tuesday PM.
?
------------------------ Jim W Phoenix, AZ. USA
Losmandy G11G w/ L6, NINA 3.0 / ASTAP, ASI2600MC Pro, Sky-Watcher Scopes, Canon L Lenses.
?
Use a drop of low torque thread adhesive on those darned Oldham grub screws.? Loose grub screws are one of the most common issues and cause a lot of grief to the uninitialized.? If you are having issues with your drivetrain those grub screws are right up there with worm axis endplay.? ? ?
?
--
Chip Louie Chief Daydreamer Imagination Hardware?
Astrospheric Forecast - South Pasadena, CA?
?
?
?
|
Re: G11G Imaging Weight Capacity for Imaging?
Hello Francisco,
?
Do not get me wrong, I firmly believe at the under $5000 budget Losmandy makes the best mounts in their class.? I owned a G11T for a year.? I thought I wanted two rigs,? it was for my C14.? It moved the C14 around, I used it for visual and it was very good.? However, I also owned two refractors at the time, that C14 was noticeably heavier to push across the grass. I donated the C14 to my local middle school for their astronomy program, the mount went to my neighbor.?
?
As Michael above pointed out,? there are a lot of things that affect pointing and tracking when doing DSO imaging.? I know you said you are just trying it out and not really going to do it. That is great.?
?
Image scale is what you need to track under.? Your periodic error has to be less than your image scale you are shooting at.? With a 2600 camera that has 3.76 micron pixels, you need to guide under .4, that is a 12 LX200 OTA with a .63 reducer.? With a 2400 camera you are at .64, more manageable but still kind of tough to do.? My opinion.? Reason,? you have a 14" barrel that is over 24" long with a dew shield on top of that mount. A 6" RA and Dec gears driving it. ?
?
My opinion, ? a mount with a 10" RA gear and 8" minimum Dec gear.? If you get serious about DSO imaging with a 12" SCT.? If it were me, and I know this is a Losmandy group, but with a 12"SCT for DSO imaging successfully an AP1600GTO, 10 Micron 2000GPS,? a Planewave or ASA mount .
?
At 50 pounds you are approaching the weight limit,? physical size you are probably over the limit, focal length you are past the limit.? The least little thing and you are done. No room for error. A gentle breeze of wind, someone walking around.
?
Planetary, visual yes. EAA yes.? DSO, I'm going with no.? Final answer.
?
Joe
|
G11 if you are interested
Hi- I was told that it would be OK to let the group know I have a G11 mount/tripod for sale.? But rather than overextend my site privileges, I'll leave it to you to contact me privately or see the ad on Astromart for details.? Thanks.? J.R., Gainesville, GA
|
Re: Did my Gemeni 2 firmware become corrupt?
I believe it was the battery
|
Re: G11G Imaging Weight Capacity for Imaging?
Hi Francisco,
Welcome to the group.?
Weight limits are SO problematic. To start it's barely a relevant measure, but marketing people had to find something simple they could use in their ads to out spec their competition. Now we're all stuck with it. ?
Hence the sarcastic commentary of "is that in 'Chinese' pounds",? or? "the rule of thumb is divide by 3 for AP" (easy to remember) or "is X makers rating real?" and now it's "it's X for visual and Y for AP" ,
(which ignores the question is that short exposure planetary or long exposure DSO AP? )
You get my drift. ???
?
Moment of inertia is the actual factor thst matters (Mass x distance from the axis of rotation). Its a bit messy to put that in an ad, much less explain it, AND it's only one factor in "suitability for a purpose" which is the? right question to ask.
?
Kudos to the seller BTW who obviously has super high integrity. ???
?
I won't get into it here, other then to say there is a big difference between a long f/10 refractor and a f/10 SCT? that might be of equal weight when it comes to "can this mount handle it"?
?
You'll fnd it discussed if you search or browse in the forum archives which i highly recommend anyway. It's a resource of all things about Losmandy. many of which you (and I) haven't yet thought to ask. ?
I jest a bit in fun, but it really, is a bit overwhelming in the best possible way.?
?
Long exposure AP at 3k mm FL is super challenging for reasons too numerous to mention. I've learned here that? the fundamental challenge is how to methodically isolate the cause of an observed issue and then how to go about fixing or reducing it. It takes experience.?
?
That's what I have come to appreciate about this group after I bought my used? older G11 mount.
?
There are many VERY experienced people and SMEs in this and related Losmandy/Gemini groups that are very generous and willing to share their knowledge and experience, which IMO is way more important than any of the multitude of factors that will impact achieving your desired results at one point or another.
?
FWIW, Losmandy makes an adapter for Meade tripods. A lot of? mounts are sold with this adapter and a Mead tripod before Losmandy started making their own tripod. I bought my used G11 in that configuration. The more modern Meade giant field tripod (LX200GPS) are ok for visual/planetary What was better was an older Giant FT from the LX200 classic. 3"+ dia legs and taller (if you are a really tall person or have a long refractor.) I bought a used Losmandy original non folding HD tripod. It's an absolute rock. I'm sure others can advise about the Folding HD tripod.
?
OT, PM plz if you still have the Meade fork mount?
I have a couple of projects needing parts.
?
Michael?
?
?
?
|
Re: G11G Imaging Weight Capacity for Imaging?
Hello Francisico
Congratulations on your G11G and Welcome to the group. I am routinely? imaging at <1 AS RMS on G11 with 53 lb counterweight for my 10 in RC at 2040 fl using OAG. Balance is critical for me and changing to Michael Hermans high friction clutch pads was a game changer. The stock nylon clutch pads just did not work for me.
Have fun
Ron
|
Re: Unable to fully lock RA axis on G11
Once I changed to the Michael Herman high friction discs I never went back. They really prevent slippage and don't come loose like the plastic ones, so you don't have to keep cranking down for them to stay put. However, they are so grippy you cannot really do a balance in RA while the mount is at the typical altitude for one's latitude needed for proper PA. But my mount is on a pier, and I can crank the altitude down to near zero so there is little downward force on the clutch assembly, and I can rock it back and forth freely to balance. If you are using a tripod, the zero-ALT position is harder to reach without tipping over or adding some hanging weights under the tripod. Still, these discs are one option for better RA stability. If RA lock is still hard to achieve, this sounds like some washer, disc or bearing in the whole assembly might be worn down to the point where a typical knob twist does not stop RA movement as there is too little contact between the mating surfaces. But the only way to check this would be to take the RA drive apart and put a micrometer on each of the parts to see if something is too thin (and with a bit of time invested).?
?
John
--
_____________________________________________________________________________________________________________________________________________________________________________
Losmandy G11G2 on pier; refurbed Losmandy G11 with OnStep controller; SkyShed design roll-off observatory; ZWO ASI2600MM-P; ZWO ASI071MC; Sky-Watcher Esprit 100 ED with field flattener; Celestron C925 Edge HD with 0.7XFR, William Optics Zenithstar 61 APO; PHD2, NINA, Sequence Generator Pro and PixInsight user
|
Thanks Brendan & Brian. I've contacted Michael Herman for repairs. He's had my Gemini-1 a couple of times before. So he's familiar with my unit. I'm shipping the Gemini-1 and Michael's 17-volt "Power-Booster" supply. He wants to be sure that isn't part of the problem.
?
As for power cords, each supply uses a different cord. The Power-Booster's cord is hardwired to that supply with a Losmandy plug on the other end. The Pyramid supply cord uses PowerPole connectors to attach the cord to that end and the Losmandy plug on the other end. Both supplies work when not attached to the Gemini-1. Each goes dead when attached. I'll measure the Gemini input jack to see if there's a dead short there. I believe the jack has 4 pins - 2 for power and 2 for ground. But Michael is the best one to fix the problem.
?
Russ
|
Re: Unable to fully lock RA axis on G11
On Mon, Feb 10, 2025 at 11:13 AM, George Cushing wrote:
Michael H's friction disks are made from what looks to me to be high temp automotive gasket material. They are very similar to the system used by Celestron on the Nexstar one armed mounts. These again are not designed for rigid mount of the saddle and should have limited slippage to protect the drive train components.
?
I was an early proponent of Michael Herman's high friction clutch discs and I use my Losmandy G11G and GM8G mounts for both imaging and visual. But if you are a dedicated imager and will never use the mount in PUSH-TO mode as it was designed to be used they are great.? I used the high friction discs for a year and a half and they never really broke-in.? They have a much higher friction level than the stock Losmandy plastic clutch discs and they do not like to be used in the slip mode, they are grabby and in the cold they can be noisy making a creaking sound when being asked to slip.? So when Scott rebuilt my G11s to the latest G11G specs he tossed them and installed new discs which restored the great PUSH-TO freedom I prefer.? ?
? ? ? ??
--
Chip Louie Chief Daydreamer Imagination Hardware?
Astrospheric Forecast - South Pasadena, CA?
?
?
?
|
Re: G11G Imaging Weight Capacity for Imaging?
On Mon, Feb 10, 2025 at 12:01 PM, Francisco wrote:
and i will be ordering a heavy duty mount from losmandy sometime next month, i dont see myself putting the 12" on there with the lightweight tripod.
One more thing, the meade SCT OTA bare weighs around 36lbs. add in the dovetail, and imaging equipment, and dew shield and im just over 50lbs, i know this is pushing the limit, but im so excited to get in to a losmandy mount.
?
Francisco, a 50 pound imaging payload is not really pushing the limit for guided imaging on a G11G mount, not at all.? My C14 fully loaded with double dovetails and Moonlite focuser and the imaging gear was over 60 pounds, I had no issues with it.? I am routinely 5-10 pounds over the official 60 pound imaging payload value and use an ASIAIR for imaging which is not quite as good at guiding for some reason as using PHD2.? But the small PE difference makes no difference in the data or finished images so I don't sweat it.? ?
?
?--
Chip Louie Chief Daydreamer Imagination Hardware?
Astrospheric Forecast - South Pasadena, CA?
?
?
?
|
Re: G11G Imaging Weight Capacity for Imaging?
Francisco
?
With any luck it will be clear enough tonight to do a PHD2 guiding run.? I adjusted the RA worm to ring gear spacing and I want to make sure I didn't mess things up.? I also found some loose grub screws.? I will contact you Tuesday PM.
?
------------------------ Jim W Phoenix, AZ. USA
Losmandy G11G w/ L6, NINA 3.0 / ASTAP, ASI2600MC Pro, Sky-Watcher Scopes, Canon L Lenses.
|
Re: G11G Imaging Weight Capacity for Imaging?
and i will be ordering a heavy duty mount from losmandy sometime next month, i dont see myself putting the 12" on there with the lightweight tripod.
One more thing, the meade SCT OTA bare weighs around 36lbs. add in the dovetail, and imaging equipment, and dew shield and im just over 50lbs, i know this is pushing the limit, but im so excited to get in to a losmandy mount.
|
Re: G11G Imaging Weight Capacity for Imaging?
Hi Jim!
Im the prospective buyer, im really appreciative of the care youre putting in to this sale, seriously.
. I Just deforked my Meade LX200 12" and its on a losmandy dovetail i got from losmandy directly.
?
With this OTA my primary targets are planetary, and there is no real guiding used during those imaging sessions. I do want to try and experiment doing DSO, and for that, i would absolutely be using an off axis guider. I have a couple to choose from. That will be reduced using a vintage starizona SCT reducer corrector ive inherited. Also this is the high end of my weights . I will also be using it with a 102mm explore scientific for most of my real DSO work.
?
so,?
?
12" mostly for planeraty, no reducer used
12" for DSO experimental imaging using a Starlight Express Active optics system i also inherited, this would be reduced by .63
?
102mm refractor for more serious dso imaging
?
8 inch C8 with a reducer for most of my SCT deep space imaging.?
?
THanks!
Francisco
?
?
|
Re: Unable to fully lock RA axis on G11
Michael H's friction disks are made from what looks to me to be high temp automotive gasket material. They are very similar to the system used by Celestron on the Nexstar one armed mounts. These again are not designed for rigid mount of the saddle and should have limited slippage to protect the drive train components.
|
Re: G11G Imaging Weight Capacity for Imaging?
How well a mount can be guided is complicated and almost all of the factors are beyond the mount itself.? Mount mechanicals, autoguider app tuning and configuration, primary imaging camera pixel size to guide camera pixel size ratio, guide scope mounting stability, guide scope camera stability, seeing air stability, cable configuration, wind, power stability etc., etc. all contribute to guided PE.? Any and all of this and more can and will screw up a night of imaging.??
?
People like to blame the mount and there are some that are a little better than others.? But most of the time the alleged "bad" mount is just a victim of who owns it and the environment in it is used in.? ?
?
--
Chip Louie Chief Daydreamer Imagination Hardware?
Astrospheric Forecast - South Pasadena, CA?
?
?
?
|
Re: G11G Imaging Weight Capacity for Imaging?
Thanks Joe and Chip.? I average around 0.8 to 0.9 arc-seconds RMS using a 200mm FL guide scope and ASI120mm camera in the city with a 25 pound imaging setup.? I rarely get any better than 0.75.? I don't recall what I get at a Bortle 4 or 2 site.? I am not sure this is typical of the G11G or just my mount.? I don't want the buyer to get a mount that will not meet their expectations.
?
------------------------ Jim W Phoenix, AZ. USA
Losmandy G11G w/ L6, NINA 3.0 / ASTAP, ASI2600MC Pro, Sky-Watcher Scopes, Canon L Lenses.
|
Re: G11G Imaging Weight Capacity for Imaging?
Jim,
?
The stated imaging payload of the G11G is 60 pounds.? Many people with heavier and longer scopes are imaging on a G11G with good results.? My friend is imagining with a 10" f/8 Newt that is well over 65 pounds with good results.?
?
I routinely load the 20+ year old G11G mount with over 60 pounds and image with it.? My guiding is very good, still well under 0.5" PE.? I normally image with the bespoke Parallax / AstroTech130mm f/6 SDT which has an oversized steel tube and 3.7" focuser and a Losmandy Side-By-Side saddle plate with ADM ALT/AZ aiming device and Meade LX200 10" f/6.3 SCT with 3" Moonlite focuser etc. etc.? this is a very heavy payload.??
?
I think the buyer should not have a problem imaging with a G11G and 50 pounds of payload.?
?
--
Chip Louie Chief Daydreamer Imagination Hardware?
Astrospheric Forecast - South Pasadena, CA?
?
?
?
|
Re: G11G Imaging Weight Capacity for Imaging?
Is the G11G 60 pound spec for visual?? I usually use 2/3 or 3/4 of the stated load capacity for the imaging spec.
------------------------ Jim W Phoenix, AZ. USA
Losmandy G11G w/ L6, NINA 3.0 / ASTAP, ASI2600MC Pro, Sky-Watcher Scopes, Canon L Lenses.
|