Hi Daniel,
Thanks for the quick response! ?I believe I am doing exactly what you describe ... best as I can tell, I'm connected to mount and everything looks correct except that when I go to?setup->configure pec, there is no option to select?2x PEC cycle or anything else ... the pulldown box is empty. ?I've waited 30 minutes, tried unconnecting/re-connecting, rebooting my PC and the mount, etc. ? ?I'm reattaching the screenshot from PC which may help someone identify what might be wrong. Thanks for looking! -Bret |
Re: RA axis movement or wiggle
Interesting, operationally the 3mm movement does not exist.? Push on the DEC shaft let go and it will return to the starting point because the force creates movement by pushing against the worm spring mechanism.? Because in use no similar force will exist to push the DEC shaft (small children excluded), no 3mm play exists in operation.? Which excludes thinking of the movement as backlash, but wiggle might apply (spring compression).
|
Re: RA axis movement or wiggle
>>>
I really thought that the direction of the arrows you see in PHD2 indicated the turning direction of the RA drive.? it's the direction of the guidepulse, but RA axis never stops or reverses On Sat, Aug 27, 2022 at 6:13 AM Daniel <daniel.rdrm12@...> wrote: On Sat, Aug 27, 2022 at 03:06 AM, Brian Valente wrote: --
Brian? Brian Valente astro portfolio? portfolio astrobin? |
Re: Resetting spring-loaded worm
I'm attaching last night log.? I'm not sure if this is the best I can post, because I used dithering and this makes analysis more difficult.? I'm aware of the machanical causes of all the main spikes in the error spectrum, but what I'm not sure is if the RA Axis could benefit from some loosening of the bottom cap screw, that is, if such loosening could smooth a little the error plot.
Best, Daniel |
Help with PemPro on G11/Gemini
Hi Folks,
I'm new to the G11/Gemini, but not to astrophotography and I have used PemPro previously with great success. ? I'm using Brian's fabulous instructions here: but, I'm stuck in Gemini PEC setup in the very beginning. ?The problem I can't figure out is that Brian's instructions show that I'm supposed "Choose 2x PEC cycle and press Set", but the pulldown box is empty (see screenshot below). ?? What am doing wrong? Thanks in advance! -Bret |
Re: RA axis movement or wiggle
On Sat, Aug 27, 2022 at 03:06 AM, Brian Valente wrote:
it guides in one direction all?the time. RA is moving in sidereal speed, so guide corrections are either speeding up or slowing down the RA movement. it's never reversing so backlash during tracking and guiding is not a performance issueThanks for the clarification. I really thought that the direction of the arrows you see in PHD2 indicated the turning direction of the RA drive.? Best wishes, Daniel |
Re: RA axis movement or wiggle
Michael has it correct, you are likely seeing the effects of the spring-loaded worm. It's not a good idea to try to zero it out, that's not how the spring-loaded worms work Roland Christen from AP did a nice writeup on this recently (AP mounts have spring-loaded worms as well) which may make for good background reading on this topic: "why is a mount springy" it guides in one direction all?the time. RA is moving in sidereal speed, so guide corrections are either speeding up or slowing down the RA movement. it's never reversing so backlash during tracking and guiding is not a performance issue On Fri, Aug 26, 2022 at 4:22 PM Daniel <daniel.rdrm12@...> wrote: Even with this backlash, how is your guiding ?? ?Backlash in RA is not a big thing as it tends to guide in one direction most of the time.?? --
Brian? Brian Valente astro portfolio? portfolio astrobin? |
RA axis movement or wiggle
How much wiggle or movement should there be for the RA axis if the spring-loaded worm and secondary screw are adjusted correctly?? ?I measured the movement of the far end of the counterweight shaft and found 3mm of movement.? This seems excessive.? ?I had less movement but was forced to back off the secondary screw because the RA motor was stalling.? ?Is there something else other than the secondary screw that might be causing/contributing to this 3mm of movement?? ?Is there anything different about adjusting the secondary screw for the RA axis compared to the secondary screw for the DEC axis?? ?The DEC axis had some movement and I was able to significantly reduce it by adjusting the spring-loaded worm and secondary screw for DEC.? ?My mount is a GM811G and is about a year old.? ?I use it a lot, about 130 nights of imaging/testing since purchase.? ?Thanks in advance for any advice.? ? --? Jim?
|
Re: Resetting spring-loaded worm
The spikes I mention can be seen in this excerpt of a PHD2 log:
As you can see the error is most of the time in a band of +-1", but there are occasional spikes. Even without the occasional spikes, I do not like too much the performance, too much oscillations with just 9 lbs of equipment (Sharpstar 76EDPH with all the typical add-ons).? With the 343mm focal length of the 76EDPH? the resulting images are perfect, but? I would like to be able to image with longer instruments (with 1200mm fl as the maximum perhaps).? I think that oscillations could be related to stiction and may benefit from a fine adjustment of the worm gear. Best regards, Daniel |
Re: rehab a G11
Bob,?
This depends on the total age of the scope, not just idle time. Sitting for 3 years might make the lubes drip through a bit, especially with higher temps. So we know the mount is 3 years + at this point. If only that old, you can do the basic clean up and relube as in the videos, plus replace or clean the clutch discs which may be worn or oily. If the scope is 5 years plus, you may want to do a full teardown, degrease and relube, but also replace some moving parts like the Oldham couplings, gearboxes and the worm bearings. The thrust bearings and washers should also be inspected at this time as well. The greases do move away from the gear surfaces with use, and also trap in dust and metal fines from the gears wearing. But make sure to replace with quality lubes like the Jet-Lube MP-50 on the worm and rings, and Jet-Lube Artic or other surfaces (which are the original Losmandy lubes). But I would recommend Mobilgrease 28 over the Artic, as this aircraft-rated grease has very good anti-wear properties. Wish I could help but I am over 3000 miles away. As mentioned, resetting the worm to ring tension takes some time and patience, if you don't have a Losmandy knowledgeable helper close by. Regards, John ___________________________________________________________________________________________________________________________________________________________________________ Losmandy G11G2 on pier; SkyShed design roll-off observatory; ZWO ASI2600MM-P; ZWO ASI071MC; Sky-Watcher Esprit 100 ED; Celestron C925 Edge HD with 0.7XFR, William Optics Zenithstar 61 APO; PHD2, Sequence Generator Pro and PixInsight user |
Re: Resetting spring-loaded worm
PE spikes can be caused by stiction which may be visualized as force ramping upward with a sudden release as the level of force applied overcomes the resistance present. There are two possibilities here, the bottom of the deck plate cap screws are just a smidge too tight or you have a bit too little lift. I would start by adding some additional worm lift using the lift adjustment may fix it but be aware the lift adjustment usually needs to be very small to maintain optimum worm tooth engagement and these are not fine threaded fasteners. So I would make the smallest possible adjustment to the lift adjuster, observe and if needed continue to adjust. It sounds like your worm is close to optimum so with a small adjustment you should be GTG. If you don't see any change the bottom side cap screws are the next place to adjust. I suggest changing the outer or left side first, test, observe and adjust, if after two cycles you see no change try cracking the inner cap screw a smidge.? You can verify the cap screws are letting the OPW move by wiggling the end of the counter weight and feeling for movement on the outer end of the OPW where the worm bearing block is attached to the OPW. There should be some movement felt on both axis or chances are you need to crack the outer bottom side cap screw a bit. Keep in mind that a little adjustment goes a long way on all of these coarse threaded fasteners.? ? Keep us posted.? -- Chip Louie Chief Daydreamer Imagination Hardware? ? ?Astropheric Weather Forecast - South Pasadena, CA? |
Re: Problem with shift PEC on a Losmandy G11
Vincent has been so kind to contact with me to report that unfortunately he was unable to solve the problem and sold the mount, moving to a CEM60. His mount used a Gemini 1, so either the problem is not tied to the Gemini or the part that causes the problem is present in both generations of the computer (code or electronics).
Thus, the problem is still unsolved and in my case means that PEC is unusable in my mount :-( Best regards, Daniel, |