On Sat, Jul 20, 2024 at 11:24 AM, <tshelley@...> wrote:
Losmandy G-11 just reworked to include the tucked motor & spring loaded worm, the problem appears after this?
modification.?
Tim,
?
It sounds like you are binding up from too much worm tension after the rebuild. With the spur gear covers off, you should still be able to turn the gears freely by hand (with power off). If you remove the motors, the gears should have just a slight bit of tension. The videos can probably show you how to adjust them as well as can be described here (I have the older non-spring-loaded type). The worm and ring should be lubed with the Losmandy original grease, the Jet-Lube MP-50, or you may have too much friction slowing movement. You should talk to whomever did you rebuild for more advice.
?
Good luck,
?
John
--
_____________________________________________________________________________________________________________________________________________________________________________
Losmandy G11G2 on pier; refurbed Losmandy G11 with OnStep controller; SkyShed design roll-off observatory; ZWO ASI2600MM-P; ZWO ASI071MC; Sky-Watcher Esprit 100 ED with field flattener; Celestron C925 Edge HD with 0.7XFR, William Optics Zenithstar 61 APO; PHD2, Sequence Generator Pro and PixInsight user