¿ªÔÆÌåÓý

Re: Usability Question


 

On Sat, Aug 6, 2022 at 03:41 PM, Mark de Regt wrote:

OP here again.

?

I really appreciate all the suggstions!

?

Two things have resonated:

?

  1. I only guestimate CWD position with my eye.? If precision of CWD matters, and if there is a simple way to get it perfect, that may be the cause.
  2. People keep taking about using plate-solve to work around the poorly-functioning Gemini2 model building.
    1. I need a camera to do that; I¡¯m happy to buy a cheap camera for that, but not an expensive one; any suggestions?
    2. I own TheSkyX Professional Edition, a very powerful planetarium program.? Would this do that is being suggested, and, if so, how?

?

Thanks again!

?

Mark

Mark,?

The maximum number of stars I use to align my G11G and GM8G Gemini 2 mounts is 4, normally I just do a 2 star alignment and GOTOs are fine. The Gemini works fine, thousands of people have proven this.?

When there is an issue it has always been traced back to #1 the data given to Gemini to solve for position including mount type, mount model, date, time, time offset, location coordinates, and format of the data issed. #2 Polar Alignment, #3 mechanical issues primarily related to drive system backlash, wind-up, endplay, lose mechanical parts etc.?

Fix these and you will resolve your issues with GOTO performance.?
?
--

Chip Louie Chief Daydreamer Imagination Hardware?

? ?Astropheric Weather Forecast - South Pasadena, CA?

Join [email protected] to automatically receive all group messages.