¿ªÔÆÌåÓýThis is a followup to using PEMPro and PEC guide rate. I have just restored the full PEC guide rate range 0.2x - 0.8x to the latest build of PEMPro, which I just uploaded. Here is the direct download link to V3.00.32 (or use check for updates in PEMPro's help menu): ? ? Here is also an example screenshot showing where to adjust the guide rate. Note that the East and West move distances are not the same. For example, the East moves are 0.241 arc-secs, and West moves are 0.130 arc-sec in the screenshot below. The move distance values can differ based on the number of cells used, the number of worm cycles that the PEC cells contain, the number of teeth in the worm wheel, and the guide-rate. ? ? ? -Ray Gralak Author of APCC (Astro-Physics Command Center): https://www.astro-physics.com/apcc-pro Author of PEMPro V3:? https://www.ccdware.com Author of Astro-Physics V2 ASCOM Driver: https://www.siriusimaging.com/apdriver ? > -----Original Message----- > From: [email protected] [mailto:[email protected]] On Behalf Of sbasprez via groups.io > Sent: Monday, August 17, 2020 11:11 AM > To: [email protected] > Subject: [Losmandy_users_io] Valid Guide Rates for PEC on Gemini Level 4 > > I have always used 0.8x as the guide rate when training PEC on my G11 with Gemini 1 Level 4.? I was just > looking at the Gemini instructions in PEMPro V3 and it has this warning:? The Gemini firmware only supports > 0.3x and 0.5x guide rates - 0.5x is recommended.? This conflicts with the description of command ID 502, > Guide Speed used for training PEC, in the Gemini Level 4 Users Manual.? That seems to indicate the full 0.2x, > 0.5x, and 0.8x range is valid.? Which is it? |