A year!!!! Flippin' 'eck! [email protected]> wrote:
By
Pete Millis
·
#3811
·
|
Re: service
Mine has been there since last December (2022). But it needed a new mainboard.
By
Matt
·
#3810
·
|
Re: service
It was 2 weeks for me - provided John has the parts just ask him
By
AH6K - Marc
·
#3809
·
|
service
Can anyone tell me what the turn around time is on service from Reno, NV?
By
Lou N9LTW
·
#3808
·
|
service
Can anyone tell me the turn around time on service from Reno, NV?
By
Lou N9LTW
·
#3807
·
|
Re: Operator error: Connected to 18V power source
Also check your replacement cord. Btw is it fused?
By
Andrey Denisyuk
·
#3806
·
|
Re: Operator error: Connected to 18V power source
Just open it and inspect power input circuits and components near the battery. Could be something trivial. If everything is ok there then things are worse that it could be.
By
Andrey Denisyuk
·
#3805
·
|
Re: Operator error: Connected to 18V power source
No. This is from the manual. It's quite clear: *OVERVOLTAGE PROTECTION* When exceeding 15.0 volts, the transceiver won¡¯t allow switching to TX mode, (the voltage indicator on the display will become
By
Norm - KC1BMD
·
#3804
·
|
Re: Operator error: Connected to 18V power source
* Dennis W6BFK <dennis@...> [Sat, Dec 9 2023 06:14 -0800]: Voltages over 15V can damage the transceiver. Attached the portion of page 10 of the manual, below the link to the PDF file at
By
Dominic OE7DRT
·
#3803
·
Edited
|
Re: Operator error: Connected to 18V power source
Spec is "External power supply DC 9-15V, 1 to 3A typical in transmit" from the site main page. You may have run at 18V and been ok but im going to call that more luck and not something one should do.
By
tim W3QP
·
#3802
·
|
Re: Operator error: Connected to 18V power source
OK,? but doesn't the spec indicate power supply to 18vdc? I'm pretty sure I've? run mine that high. 73
By
Dennis K4IN
·
#3801
·
|
Re: Operator error: Connected to 18V power source
Unfortunately, I doubt it, if you read the section " *Overvoltage Protection* " in the user manual. -- 73, Norm/KC1BMD
By
Norm - KC1BMD
·
#3800
·
|
Re: BP500 Questions
Has anyone received a recent shipment from HRO?? I had heard they recently received another batch. TU & 73 Dennis W6BFK
By
Dennis K4IN
·
#3799
·
|
Re: Operator error: Connected to 18V power source
That's interesting.? I seem to recall running mine on 18v before with no issues.? I would definitely send it for repair.? It may be a warranty issue. GL & 73 Dennis
By
Dennis K4IN
·
#3798
·
|
Operator error: Connected to 18V power source
The fuse went instantly. ?I replaced the power cord with a new Digirig cord and the TX500 will not power up when connected to a Samlex 12V power source. ?I have not opened the TX500 up and am
By
N8XMD
·
#3797
·
|
Re: BP500 Questions
I received this reply from Roman at LAB599 tech support answering my questions: Hello David, Thank you for contacting lab599 support! 1. You can use batteries of different capacities, but the total
By
David Holmgren K9AT "Ruffers"
·
#3796
·
|
Re: latest on the BP-500
Just completed a full charging cycle with my new BP-500 and I'm getting 4.15v (+/- 0.01v), on all 6 cells. Perfect! Loving the BP-500 so far.
By
Luke / AD0KI
·
#3795
·
|
Re: BP500 Questions
The BP-500 is setup as 3s2p, so using 3500mah cells that gives a total capacity of 7ah. Best in class by a long ways. Just a side note: the supplied AC/DC charging adapter is very RF noisy on all HF
By
Luke / AD0KI
·
#3794
·
|
Re: BP500 Questions
What is the total Ah size of the BAT500??? Ammed Ismail KN6STX
By
Ammed Ismail
·
#3793
·
|
Re: BP500 Questions
Just received my BP-500 this afternoon from HRO. Fit and finish are excellent. HRO sent the radio with good quality Samsung 3500mah cells. I already confirmed direct solar charging from an AllPowers
By
Luke / AD0KI
·
#3792
·
Edited
|