¿ªÔÆÌåÓý

Date
Re: Need E5515C help on mods and features
The E5515C series is in fact discontinued, not current. the options specifically say that other frequency coverage is possible (270-1300Mhz at least), I am trying to find out how to do it. the docs
By walter shawlee <walter2@...> · #103584 ·
Re: [WANTED] HP 85700A 32kB RAM card
Hi Steve, Page 3 of the *CONFIG* menu for the sync settings, not the CAL menu. -mark
By Mark Litwack · #103583 ·
Re: Need E5515C help on mods and features
Not necessarily; these are current (or very nearly current) analyzers. I don't know if there's any way to expand the range. This is a cellular test device; it's very tightly tailored for, well, you
By Dave McGuire · #103582 ·
yet more hp CRTs for stuff day
Further to the list I posted, I went to our offsite storage unit, and found another big pile of HP CRTs, including many new ones. the additional ones include (all prefix 5083): -4454, (2) -5152
By walter shawlee <walter2@...> · #103581 ·
Need E5515C help on mods and features
I got one of these (working) off ebay, with option 2 (2nd generator), and would like to expand the RF coverage range. I understand there is an option for this (I have no use for the cell features),
By walter shawlee <walter2@...> · #103580 ·
HP-5354A, Schottky Diode 1900-0023
Hello all, just joined the group. My second HP piece is next to me, a 5345A with a 5354A plugin. The 5345A seems to work fine, but the plugin doesn't. My investigations are now on the A1 mixer. I
By Andreas Tobler · #103579 ·
Re: [WANTED] HP 85700A 32kB RAM card
At 2020-03-02 08:56 AM, Mark Litwack wrote: On the screen issue, try the display centering adjustments on the second page of the CAL menu. Thank you, I was hoping for something like that.
By Steve Hendrix · #103578 ·
Re: sick hp 5421A Digital Processor
It's true that the interests on the GammaSpectroscopy list are mostly about gamma spectroscopy measurements and materials, and less about the instrumentation. The common focus on using PC sound cards
By Dave McGuire · #103577 ·
Re: sick hp 5421A Digital Processor
Yup, I've been nonfunctional due to painkillers following a small oral surgical procedure. I should have that info for you by tomorrow. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By Dave McGuire · #103576 ·
Re: sick hp 5421A Digital Processor
Hello Dave, just in case my e-mail reply to your kind offer ended in your spam folder: you got mail ;-) Kind regards Chris
By ChrisBeee · #103575 ·
HP 5347A with 8482A Power Sensor?
Hello group. Wondering if anyone has tried using the 8482A power sensor with the 5347A. It is the only sensor I have. Power ranges are the same but not the frequency range so clearly cannot measure
By Mark Bielman · #103574 ·
WTB HP 8660C Module Extension Cables 11672
I wish to buy the Service Kit p/n 11672A, or the two extender cables, p/n 11672-60001 and 11672-60002 for the 8660x signal generator series. Please contact me off list if you have something for sale.
By Bob Koller <testtech@...> · #103573 ·
Re: HP3336b
To quote Wikipedia, as just one example.... "An RCA connector, sometimes called a phono connector or (in other languages) Cinch connector, is a type of electrical connector commonly used to carry
By Nigel · #103572 ·
Re: A dirty way to get more frequency resolution out of a signal generator
This will probably work but you would need a counter to verify the output signal is what you are expecting. There is no guaranty that a low resolution generator will be able to hold steady on digits
By victor.silva · #103571 ·
Re: [WANTED] HP 85700A 32kB RAM card
Hi Steve, On the screen issue, try the display centering adjustments on the second page of the CAL menu. If that doesn't help. over-scan and centering problems can also be caused by the wrong sync.?
By Mark Litwack · #103570 ·
Re: HP3325 - no output, but sync works
Simple check is to take the cover off, locate the attenuator board and find the input cable. Put a scope on that and it should have a signal ¨C this would prove the rest of the generator is
By nigel adams · #103569 ·
Re: HP3325 - no output, but sync works
Odds are the attenuators is shot. If it has the flat black aeromat relays you won¡¯t hear them even if the work. They are latching type so checking the drive signal will only give you a plus. You
By Stephen Hanselman · #103568 ·
Re: LO port on HP 8591A
Thanks, your comment made me laugh. Glad to hear its not just about saving $20 anymore and we now actually have another brand/series of SA that it can be used for.
By Marcus Bannerman · #103567 ·
Re: Hi all..have a question on a source for micro-grabber clips (smd size)
Something like HP 5090-4356? Plenty around on ebay at a $ or so each. wrote:
By Orin Eman · #103566 ·
Re: Hi all..have a question on a source for micro-grabber clips (smd size)
I don't know if something like this is what you're talking about, but I thought I'd offer it on the chance that it was what you're looking for.
By G Hopper, KB7WSD · #103565 ·