Re: Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet)
开云体育?Thank you, Steve.
And Jeremy made me laugh out loud, I've seen examples of System I with "removed" handles. From: [email protected] <[email protected]> on behalf of Steve A via groups.io <starmux64@...>
Sent: Wednesday, April 22, 2020 12:06 AM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment]Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet) ?
Some photos of System I and System II Cases on my website.
Steve
On Tuesday, April 21, 2020, 11:32:01 PM GMT+1, Jeremy Nichols <jn6wfo@...> wrote:
That’s System II. They have removable handles. System I handles are part of the cast aluminum alloy side panels are are removable only by dropping the instrument from a considerable distance onto the handle. This process is not reversible!
Jeremy?
|
Re: Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet)
开云体育?The 339A?is System II. ?Perhaps you are thinking of the 331A through 334A which are System I.
Dave Wise From: [email protected] <[email protected]> on behalf of Robert G8RPI via groups.io <robert8rpi@...>
Sent: Wednesday, April 22, 2020 12:38 AM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet) ?
The System II designation refers to the second design of MODULAR case. Not all HPAK instruments use modular cases. Obviously the ones pre-dating? it? can't.
HP sold both original and System II cases along side each other at least into the seventies. Note that not all original modular cases (System I) had handles cast integrally with the side frames. you can't use absence of handles to determine case type. |
Re: HP K21-5321B Digital Clock
开云体育Hello, Steve,
Am 21.04.2020 um 18:43 schrieb Stephen
Hanselman:
|
HP8510C Firmware C.07.00+
Gerhard Hofbauer
Hi,
I recently bought a 11575J Firmware upgrade kit, the 85101-80114 security key works fine, not so much the Firmware Floppy Disc (81501-80116). There is a disc error and the PG_8510C File is corrupted. Could somebody be so nice and send me a copy of the content of this disc? with very kind regards, Gerhard. |
Re: Test Equipment For Sale
Hi Rich, Yes, I do. Kindly, Michael On Wed, Apr 22, 2020 at 11:27 AM Rich De <rich.kcsa@...> wrote: Do you still have the 8594E? |
Re: HP8562A Errors 304,335,317,333
开云体育I've opened up the case, and even if I
don't touch the electrolytics, I'm going to have to replace the
"delayed action smoke grenade" Rifa capacitors, before they
detonate.
That will give me some idea of how difficult it would be to replace the electrolytics. On 22/04/20 12:18, Peter Hansen wrote:
|
CRT Monitor module from HP8953E Available...
Gang,
I recently replaced a video monitor module in a HP8953E.? The original module had a small burnt section on one of the boards.? The CRT was producing bright and clear images before the module quit, but does have a slight burn, but should not be a problem.? I suspect the high voltage transformer is defective. The module is marked: Omni Vision, Inc P0615E3Y 970513 266 I believe this module is used in several different products. I would be happy to give this to a good home for only shipping cost or free pickup in the Los Angeles area. Burt, K6OQK biwa@... -- Burt I. Weiner Associates Broadcast Technical Services Glendale, CA 91201 U.S.A. K6OQK |
Re: Test Equipment For Sale
On Mon, Apr 13, 2020 at 09:44 AM, Michael Yellin wrote:
I am parting out an HP 8594E.??Let me know what you want/need, and we can discuss pricing, or, make me an offer on the entire thing.Hmm, I just today joined this group, and also in the last couple of days killed my cash reserves buying some HP gear; a 4140B pA meter, a 4192A? impedance analyzer, and a couple of other big heavy HP things. Shipping of which is going to be a real $train. I'm in Sydney Australia, use a reshipper in Hawthorn LA Calif. Now I read this. How is that 8594E part-out going? Because... I have a sick 8594E, my first ever spectrum analyzer which was bought as working last year, but wasn't. Trouble is I don't yet know what's faulty, the repair is stalled, and I can't afford to make an offer for your entire one. Awkward timing. The story is here: http://everist.org/NobLog/20190223_full_spectrum.htm |
Re: WTB: 5265A Digital Voltmeter for HP 5245L Electronic Counter.
I think I have 2 dc voltmeters plug-ins 2 counters and more different plug-ins I can sell them but I am from Slovenia regards, Borut V V sre., 22. apr. 2020 ob 18:02 je oseba Jeremy Nichols <jn6wfo@...> napisala:
|
Re: Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet)
On Wed, Apr 22, 2020 at 12:38 AM, Robert G8RPI wrote:
The quirk of groups starting a new thread if you reply to an email is very annoying.Regarding the new thread creation, I was thinking that it was caused by members changing the subject block when replying to an existing thread. Whatever the cause I agree that it is annoying. Hopefully the moderator will solve the issue. The problem seems to be more common on this group than on other IO groups. |
Re: WTB: 5265A Digital Voltmeter for HP 5245L Electronic Counter.
I have a 5265A but not for sale. They show up on the auction sites occasionally but seem to be scarce. The blank covers are even rarer; the only ones I’ve ever seen for sale were part of a counter for sale. I wish you success in your search, Terry. On Tue, Apr 21, 2020 at 10:42 PM Terry Gains <terry.waihi@...> wrote: Good Morning, --
Jeremy Nichols 6. |
Re: Problem with HP MMS 70000, USERLOCK ON
开云体育Hi Pierre ? 40 manuals a r now on the HP 70000 Group site? along with a folder called ? Notes for? MMS And in there is an XL sheet for? 2 of the key boards I did last year and a few more bits of handy information ? The folder 70000 MMS had a very comprehensive catalogue that is worth printed out and binding ??unfortunately it is missing 2 pages but the catalogue is a mine of information ? Regards Paul From:
[email protected]
[mailto:[email protected]]
On Behalf Of Pierre-Fran?ois
(f5bqp_pfm) ? PROBLEM SOLVED ! |
Re: HP 3314A manual needed
开云体育Hi ? Thank you for posting the link as my manual was missing the schematics ? By the way I think I have seen a face lift version if so ?did they change the CCT ? ? Regards Paul From:
[email protected]
[mailto:[email protected]]
On Behalf Of amirb ? sorry but the one on keysight has all the chapters including servicing
and adjustment and also schematics? No virus found in this message. |
Re: HP8562A Errors 304,335,317,333
开云体育Drat :)
I've used the shunt technique in the past, and I definitely won't admit to leaving a shunt in permanently. I'm not sure what to look at next. The 8562 or a Datron DC calibrator, where the cal out isn't working - where the cal out voltage can be +-1kV :) Thanks again. On 22/04/20 12:18, Peter Hansen wrote:
|
Re: Problem with HP MMS 70000, USERLOCK ON
PROBLEM SOLVED !
After the memory card was unplugged from the CPU card which has retention the battery and then plugged again the problem disappeared. Conclusion the ERASE ALL of the analyzer doesn't clear properly the internal memory, the only way to do a real clear is to disassemble the memory card from the CPU board of the 70900B. I presume also for the A version. Thanks to all of you who helped me. 73's pf -- Pierre-Fran?ois, F5BQP JN18AN |
Re: HP 3314A manual needed
However our copy is the 90021 not the later 90025 I think the original poster was looking for
toggle quoted message
Show quoted text
Dave manuals@... On 4/22/2020 7:05 AM, ArtekManuals wrote:
We have a an excellent copy with no missing sections-- Dave Manuals@... www.ArtekManuals.com --
This email has been checked for viruses by Avast antivirus software. |
Re: HP8562A Errors 304,335,317,333
开云体育
Hello Tom those are switchmode related. I think you would benefit from recapping it. But as I said be carefull I one time lost connection to a middle layer and had bigger spurious. Had to trace it down. There are not many caps a few of the 180uF 3legged those
can be changed to 220uF 40-50V 105 degree type.
There are a few 1000uF and a 4700uF for 5V supply. You can also try to shunt the mounted ones to find the source of the problem. In your case I would chase it as it is rather bad.
best regards Peter
Fra: [email protected] <[email protected]> p? vegne af Tom Gardner <tggzzz@...>
Sendt: 22. april 2020 13:08 Til: [email protected] <[email protected]> Emne: Re: [HP-Agilent-Keysight-equipment] HP8562A Errors 304,335,317,333 ?
Thanks for a very fast response. The pictures are
with spurs at +-31.8kHz (-70dBc) and harmonics such as +-63.7kHz (-72dBc). I can't remember whether those are from the cal out or a separate OCXO I "repurposed" from a scrapped MDA. In any case the results are similar, and occur at other frequencies. Given that it is a 1989 machine with 630 hours, raised ESR is a good bet. While I have recapped PSUs before, I don't like doing it where there are ground planes. On 22/04/20 12:00, Peter Hansen wrote:
|
Re: Problem with HP MMS 70000, USERLOCK ON
开云体育1) Yes, it was running during many years !2) Too bad ... 3) I'll re-install the CPU+Mem? boards and as I unplugged the Memory board from the CPU where the battery is located I'm sure the old programs are gone. 4) Not necessary it worked for years, this isn't a compatibility of the DLP with the last OSA firmware. If really needed I could reinstall the old PROMS as I installed PLCC sockets several years ago with the new firmware. I would like to avoid to do this because time consuming. 5) As I discovered this problem with the already loaded DLP since years and then with a fresh load (this morning) from the original personality I'm pretty sure than the DLP isn't faulty. For the moment I would suspect a faulty RAM, will continue to investigate. 73's pf Le 22/04/2020 à 12:43, jfphp via
groups.io a écrit?:
--
Pierre-Fran?ois, F5BQP JN18AN |