Re: HP8903B - Plotting from HP-IB
Thanks Mike, I will buy the HP82357B interface, then update you on the results. -- Cheers Attilio
By
Attilio
·
#122474
·
|
Re: HP-8753E Option Key Installation Failure
Hi Jeff: I am afraid there is no schematic. That is the biggest part of this troubleshooting endeavor. I am relying on the EEPROM Data sheet to draw conclusions. Then data sheet tells one simply how
By
Rich Miller
·
#122472
·
|
Re: Agilent E4416A series power meter
The E4416A is very similar to the E4418/19 series.? The power circuit is the same.? The measurement boards are different.? The schematics for the E4418B are in this package
By
Tom B
·
#122471
·
|
Re: Agilent E4416A series power meter
If I am correct in a quick interpretation in the service manual the power switching comes from MOSFETs located on the processor board which distribute the power to the remainder of the instrument.
By
Greg Muir
·
#122470
·
|
Re: HP8903B - Plotting from HP-IB
Attilio, I use Pete Millett's software.? It is no where near an Audio Precision GUI but I credit Pete and am thankful for his effort in providing this for all 8903B users.
By
W6KX
·
#122469
·
|
Waveguide items OT
Sorry for a bit OT. Before I waste my time advertising on the test-equip-trader; would anyone be interested in waveguide items? WR90 (10GHz), some lower frequency, some higher (25GHz? I will have to
By
peter bunge
·
#122468
·
|
Waveguide items OT
Sorry for a bit OT. Before I waste my time advertising on the test-equip-trader; would anyone be interested in waveguide items? WR90 (10GHz), some lower frequency, some higher (25GHz? I will have to
By
peter bunge
·
#122467
·
|
Re: Agilent E4416A series power meter
Agree w/Greg on the poor service manual. No schematics! You need to investigate the "soft start" circuit. There should be a standby supply voltage present for that to work. This repair video talks
By
Mark Bielman
·
#122466
·
|
Re: Agilent E4416A series power meter
the battery is 3v.https://youtu.be/KV6pEl5kAUw I measured the battery connected and the device is not connected to the 220 v sector. my device a month ago works well I was on vacation when I came back
By
youneshilali048@...
·
#122465
·
|
Re: HP8903B - Plotting from HP-IB
Thank you so much Radu, I have already downloaded Agilent VEE version 9 and version 15 libraries and installed them on my PC. I also downloaded Pete Millett's four programs for HP8903B. I don't know
By
Attilio
·
#122464
·
|
Re: HP detector
Hi Dave, Your belief is correct. GW Pickard¡¯s patent 836531 shows an early version of what later became the standard diode symbol. The anode and cathode assignments happened later ¡ª initially, it
By
Tom Lee
·
#122463
·
|
Re: HP 8595E Restore and Tracking Generator Questions
Well I pulled the cover off and unsoldered on lead from the switch.? Sure enough it was open.? I hit it with some deoxit from the top where there was a grove going in and worked it a bit and it
By
Chad
·
#122462
·
|
Re: Agilent E4416A series power meter
My apologies. I May have misunderstood your issue. I was thinking about the internal battery option for use of the instrument without any mains power applied. The 2.9V you measured most likely applies
By
Greg Muir
·
#122461
·
|
Re: HP detector
OK, we have replaced the diode in our 8471A, and learned a few things along the way. In my preceding descriptions, I had Anode and Cathode reversed (for the standard Negative Output model). It is
By
Dave Wright
·
#122460
·
|
Re: Agilent E4416A series power meter
I have a E4418B power meter that uses the E9287A battery. It is a 12V battery. Does your meter use the same?? Part number and normal voltage should be printed on a label on it.?? If yours is the
By
Greg Muir
·
#122459
·
|
Re: HP-8753E Option Key Installation Failure
I get a hint the op may not be very familiar with digital logic, so I need to mention the idea of inverted logic values where true is low or ground. The data sheet or schematic shows this as a bubble
By
Jeff Furman
·
#122458
·
|
Re: HP 54645A internal battery
The scope came with A.02.08 firmware which I believe is the latest. ?Updated my old scope with this firmware and it works fine. ?If I get time tomorrow I¡¯ll upload the firmware images to the files
By
Manuel Maseda <mmaseda@...>
·
#122457
·
|
Photo IMG_1605.jpg uploaded
#photo-notice
The following photos have been uploaded to the 8471A Internals ( /g/HP-Agilent-Keysight-equipment/album?id=272489 ) album of the [email protected] group. *
By
[email protected] Notification <noreply@...>
·
#122456
·
|
Agilent E4416A series power meter
I have agilent E4416A series power meter. the voltages are ok 12v,-12v, 5v and the battery measures 2.9v the stand by light is on but when I press the power button nothing happens you can help me and
By
youneshilali048@...
·
#122455
·
|
Re: HP8903B - Plotting from HP-IB
Atilio, You may also want to look into Pete Millett's software - http://www.pmillett.com/hp_8903_software.htm. No affiliation, but wanted to save you the time to search. You'll also need a HPIB/GPIB
By
Radu Bogdan Dicher
·
#122454
·
|