CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Agilent ET33074-6024 cable assembly
Hi all, Was browsing eBay and I notice a number of Agilent ET33074-6024 cable assembly's available. Does anyone have information on them ? Googling around only produced links back to eBay and a direct
By
Tim Tuck
·
#94744
·
|
Re: HP4263A LCR meter
At 2019-02-27 01:27 PM, pianovt via Groups.Io wrote: There are some options available. One is the addition of the 20 kHz measurement frequency. It's firmware enabled Do you happen to have a reference
By
Steve Hendrix
·
#94743
·
|
Re: LCR meter advice
I am familiar with the 4263A and the B. I would not buy the A version again because of the poor user interface and its unlit LCD display (no back lighting). It's actually unpleasant to look at that
By
pianovt
·
#94742
·
|
3325A offset problem driving me crazy
Hi, Here is a problem that initially seemed to be easy, but now driving me crazy. I'm working on a 3325A, which has an offset problem. The symptom is that when selecting sine wave, the output goes to
By
Szabolcs Szigeti
·
#94741
·
|
Re: LCR meter advice
Hello, Bought mine much the same way. However, keep in mind that these have a lot of relays - on mine, the meter does not work in some particular modes. IMHO, this is caused by a tired relay...sadly,
By
Tam Hanna
·
#94740
·
|
Re: LCR meter advice
Hi Reg, I don't know much about the 4274/4275/4284/4285 LCR meter, but I would like to mention the 4262A. It is much more limited than the others (only 4 or 5 different test frequencies, only 3 1/2
By
Tobias Pluess
·
#94739
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
I was quite impressed for the price.? I actually bought an extra set and updated my DER EE DE-5000 LCR meter to have a proper set of Kelvin leads.? Another set stays attached to one of the HP
By
gregdunn@...
·
#94738
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Greg, I have personally examined those Kelvin clips from China and forgot about that source.? You are correct, they really are not too bad performance wise and an excellent buy at the price.? You
By
[email protected]
·
#94737
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Excellent, George!? I look forward to seeing the video. For those who are interested, it's possible to find some really decent inexpensive Kelvin leads on the Bay.? The ones I have are made from
By
gregdunn@...
·
#94736
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
[co-moderator here] A great many of our members use this as a mailing list, not a web forum, FYI. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By
Dave McGuire
·
#94735
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Readers,? I have been monitoring only this thread and Greg's thread: HP 3468A - Working, so far Any questions directed to me concerning the 3468 and 3478 or other Hp voltmeter products should be
By
[email protected]
·
#94734
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Alex, No problem answering your questions.? It has been a mental exercise for me to reconstruct and remember the design evolution of the "Key" project -- I have been enjoying it.? Actually, I have
By
[email protected]
·
#94733
·
|
LCR meter advice
Thanks to all for their comments on VNAs. I got a very nice 8753B & 84046A from Vladan. That forced me to cry "uncle" I and am now looking for a rack for this stuff. So I have room for more, at least
By
Reginald Beardsley
·
#94732
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
On Tue, Feb 26, 2019 at 11:39 AM, ghnatiuk@... wrote: > > > > Again you are correct about the Ohms calibration:? 2 Wire or 4 wire but > not both.? ? > This was a tough decision to make because
By
Alex
·
#94731
·
|
Re: HP6632A power supply: 2mV output even when output is disabled!
OK, I can accept the following answer: "like most bench power supplies, unless you have the optional output relay board, the output is always connected to the output devices so some small offset from
By
Emanuele Girlando
·
#94730
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Close - I used to think that, too, but further digging and experience shows that the the prefix is actually the major engineering revision the unit is built to - the actual production date could be
By
Cubdriver
·
#94729
·
|
Re: HP6632A power supply: 2mV output even when output is disabled!
I've now looked at the schematics and like most bench power supplies, unless you have the optional output relay board, the output is always connected to the output devices so some small offset from
By
Robert G8RPI
·
#94728
·
|
Anyone know What HP units the HP INA-12063 Transistor ( ~ 2 GHz) was used in ?
Wondering what the HP INA-12063-BLK ? ~ 2GHz transistor was used in ? I have a small package of them, dated 1998; ? spec sheet is on line. ? ?Wondering if they might help with my HP 8568 front
By
gren
·
#94727
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Alex, Yes, that is the way Hp did serial numbers back in the 70s and 80s but do not know if Agilent kept the tradition. The 4 X 5 serial number of instruments had the following scheme: ? ?
By
[email protected]
·
#94726
·
|
Re: My $25 "In Poor Shape" 3468A has arrived
Mentioned in the 3478A thread but may have gotten buried:? Why does the firmware on the 3468A and 3478A behave differently on the low range VDC display?? A 1 mV input would show "1 mVDC" on the
By
gregdunn@...
·
#94725
·
|