CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Unleveled E4436B
Hi Colby, I can still change things via GPIB, no problem so far, my simple Labview(Student Edition) program still works :) regards Tim de VK2XAX
By
Tim Tuck
·
#94298
·
|
Re: Unleveled E4436B
Are you able to select those frequencies via GPIB? I am trying to decipher my 'work' notes to determine exactly why I determined the Model needed to be changed..... but... those software options are
By
Colby Burkett
·
#94297
·
|
Re: Unleveled E4436B
Hi Colby, Frequency changes works nicely :) I haven't worked out the math for the host id either regards Tim
By
Tim Tuck
·
#94296
·
|
Re: HP34702A Ohms converter issues
If you're measuring about 2 mA test current in the 1 K range, it's about twice what it should be, so focus on the opamp U3 circuit. The key is to have the 1 volt drop on the reference resistor string,
By
Ed Breya
·
#94295
·
|
Re: Unleveled E4436B
I am definitely going to try this, again, myself. I swear that when I only changed the upper limit, I wasn't able to dial to the new upper limit until I changed the model. I hope I am mistaken.
By
Colby Burkett
·
#94294
·
|
FS Agilent HP 8656B GENERATOR 0.1-990MHz + Opt 001 recent Calib
For sale - HP 8656B signal generator, 100 KHz to 990 MHz, with HPIB interface and Option 001 High Stability.? * Recent calibration up to 3-18-2017, kept indoors, non-smoking. * Operates well, very
By
Ron
·
#94293
·
|
Re: Test fixture for dielectric measurements
Attached is a booklet from NPL on dielectric measurements. Is is noteworthy they advise against the term "dielectric constant" as no dielectric has constant properties. Dave. > Dielectrics GPG - 2003
By
Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...>
·
#94292
·
|
Re: HP34702A Ohms converter issues
Joel, your thoughts are always illuminating! 1K range, loaded by my Fluke 8600A in mA mode - 2.08 mA R55+R56 = 2.1V U3-3 to U2-6 = 2.06V Completely consistent, though the wrong values. ;-)? I checked
By
gregdunn@...
·
#94291
·
|
Re: VNA advice wanted
[email protected]> wrote: In case you are not aware, VNAs are good around 50 ohms, but the uncertainy in reflection rises quite a bit if the reflection coefficient is high, or obviously in
By
Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...>
·
#94290
·
|
Re: VNA advice wanted
Thanks! That's where it is. I *really* do need to read the manual. I just hate reading long texts on a computer. Dimension is relevant to resolution, but conservation of energy still applies which
By
Reginald Beardsley
·
#94289
·
|
Re: VNA advice wanted
Hi Regi. Measuring the performance of "EMI" filters can be done many ways depending on what kind of data or information is required. There are so many different kinds of filters and so many different
By
Gedas
·
#94288
·
|
Re: Test fixture for dielectric measurements
drkirkby@...> wrote: I can maybe do this a bit later when I get the time for it... The test jig has SMA connectors, the BNC's are just adapters. All the SMA connectors are screw
By
Askild
·
#94287
·
|
Re: 8753A VNA Repair
I have a TL866 eprom programmer, and they don't cost much on ebay.. It has worked fine for me. I too have a 8562A, and when updating the firmware to latest, I also replaced the eeprom with a 28C16,
By
Askild
·
#94286
·
|
Re: VNA advice wanted
oops, I meant DSO1102G oscilloscope by the way, when you put the 8560A in DC coupled mode, be very careful of not applying any DC voltage to the input specially if the attenuation is low. It can
By
amirb
·
#94285
·
|
Re: VNA advice wanted
on my 8560E the AC/DC coupling is under Amplitude softkey menu on the second page. It's probably the same on 8560A because on my 8596E it is also under the amplitude menu your analogy with seismology
By
amirb
·
#94284
·
|
Re: Test fixture for dielectric measurements
Is there any chance you could take some detailed photographs and detailed dimensions? I have looked at the manual, but some more details would be nice. What of the BNCs connect to the guard ring?
By
Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...>
·
#94283
·
|
Re: VNA advice wanted
For occasional use, I like the 8753 for its all-in-one-box construction and simple calibration procedure. I find the 8510 more demanding of the operator, excellent though its performance is. The 8753
By
alwyn.seeds1
·
#94282
·
|
Re: HP34702A Ohms converter issues
Hi Greg, Trying to find some logic process here... Here's my attempt: - Let's first forget about the high-megohm problem, and focus on intermediate ranges for the time being. - On the 1K ohms range,
By
Joel Setton
·
#94281
·
|
Re: 8753A VNA Repair
Hello Walter and Askild, and others interested.... A very important topic indeed. I was always wondering how long an EPROM would last, in practice. I have a lot of HP EPROM containing equipment that
By
Harke Smits
·
#94280
·
|
Re: Unleveled E4436B
Hi Tim, You can use: ?41310111.15332 to get: GB41310111?41310111.525391 US41310111?41310111.328125 MY41310111 But You do not need to change the serial to get the frequency update. Only change the
By
Peter
·
#94279
·
|