CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Tips on repairing the stick attenuator in the HP86603A
Part number would be 86603- 60074
Never had to fix on so can't help further
Robert G8RPI.
By
Robert G8RPI
·
#92770
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
Perhaps a picture would be useful too.
Daun
Daun E. Yeagley II, N8ASB
By
Daun Yeagley
·
#92769
·
|
Re: 50 ohm thermocouples was RE: [HP-Agilent-Keysight-equipment] Issue with homemade diode power sensor for HP meters
Ham Radio magazine (Dec. '77) had an article on building a "bolo-meter" type rf power meter ...Used small light bulbs in the sensor . I found a few pilot lights from old cb's that had the right
By
jim
·
#92768
·
|
Re: Readings from 436A power meter using 82357B USB-GPIB?
Hello,
Addressing another device using interactive IO doesn't seem to release the 436. What I did find out though was that viRead - wich is what interactive IO actually does - gets 14 characters
By
Staffan
·
#92767
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
I guess a part number for the attenuator in question would help.
Everyone does not have 86603A manuals to check the part number.
The o-ring failures are quite common.
The attenuators with o-rings are
By
Glenn Little
·
#92766
·
|
Re: 50 ohm thermocouples was RE: [HP-Agilent-Keysight-equipment] Issue with homemade diode power sensor for HP meters
Chuck and others,
No doubt you are right about the small light bulb been used: Here is my memory from EE school:
In ancient times, the 1960’s (if I remember right) a bolometer system was
By
Roy Morgan <k1lky68@...>
·
#92765
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
I had asked if anyone was familiar with this type of atten. NOT the 8495 style, but a long stick. I guess no one reads. NO O rings.
JeffIn a message dated 11/20/2018 7:02:42 PM Eastern Standard Time,
By
Jeff Kruth
·
#92764
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
NOT O Rings. Different design than the small flat guys.
By
Jeff Kruth
·
#92763
·
|
Re: Readings from 436A power meter using 82357B USB-GPIB?
Try addressing another device?? (Even one that doesn’t exist...)
Dave B (G0WBX)
------------------------------------------------------------------------
*Re: Readings from 436A power meter using
By
Dave_G0WBX
·
#92762
·
|
Re: HP8555A attenuator switching characteristics - notes and questions
Hi Ed,
The output pulse is inhibited while the switch is rotating by?the pulse from?contact 4F on S1 (attenuator level) this feeds an RC network R18/C4 and Q2 on A7. If you turn the switch too fast
By
Robert G8RPI
·
#92761
·
|
Re: Readings from 436A power meter using 82357B USB-GPIB?
Hello,
Indeed a point. Not having a second 436 around, I will try this one and see
where it gets me for now, but if anyone would send me a 436 - I’d be happy
to test :-)
Regards,
Staffan
By
Staffan
·
#92759
·
|
Re: Readings from 436A power meter using 82357B USB-GPIB?
It’s not impossible that you have a stuck gate somewhere, and the operation you observe is not normal for the instrument. It’d be worth checking that against another 436A.
Cheers, Kuba
By
Kuba Sunderland-Ober
·
#92758
·
|
HP8555A attenuator switching characteristics - notes and questions
I'm fixing up a magnetic step attenuator salvaged from an 8555A SA plug-in, to use in my TG project. I have some of these nice old attenuators, and the special rotary wafer switches that encode the
By
Ed Breya
·
#92757
·
|
Re: A homemade diode power sensor for HP meters
Beginning at around 47:50, in the following video,
https://www.youtube.com/watch?v=py06VNvykTk&t=2939s
he discusses HP tc and diode power sensors, and shows a strip down of a diode one.
There is some
By
Roy Thistle
·
#92756
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
I have never failed to locate a needed o-ring at Mcmaster Carr.? Google their catalog.
Sent from my T-Mobile 4G LTE Device
By
George Onufer
·
#92755
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
Here is a video on repairing one of these attenuators:
https://www.youtube.com/watch?v=eChxU90OgGk
The O-Rings are 2mm od x 1 mm id x 0.5mm thick.
Theses are used in watch
By
Glenn Little
·
#92754
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
Hey Jeff. Have you measured one to check the size? I have several
sources that might be able to supply them -
73,
Bo L.
By
Bo Lowrey W4FCL
·
#92753
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
Sounds like the universal problem of decaying O-rings Jeff.? They are easier to replace than source.
Dan
By
Dan Rae
·
#92752
·
|
Re: WANTED: HP 606B Sig Gen RF Output Attenuator Module A10
Hi Jeff,
I would be very grateful to receive it, whether it is for a 606A or 606B. Beggers can't be choosers! I'll await your advice. (Fingers crossed!).
Hi Kim,
It may also be possible for me to
By
Graeme Dennes
·
#92751
·
|
Re: Tips on repairing the stick attenuator in the HP86603A
Hi All!
Dont ask why, but I am resurrecting several HP 8660D generators with the HP86603A plugin. The attenuators are "sticky", get stuck in a certain position. If you have experience with this exact
By
Jeff Kruth
·
#92750
·
|