¿ªÔÆÌåÓý

Date
Re: Welcome to [email protected]
Excellent move Sir. Nice move. Dave B. -- Created on and sent from a Unix like PC running and using free and open source software. ::
By Dave_G0WBX · #90639 ·
OK ....
Hello : tanks You .
By Ren??F6BKB · #90638 ·
Re: migration test message
Ok here
By Leo Kroonenburg · #90637 ·
migration test message
hell just to check ! thanks
By F1CHF · #90636 ·
Re: HP-Agilent-Keysight-equipment
It has not completed yet. Dave
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #84216 ·
HP-Agilent-Keysight-equipment
Completing the transfer from Yahoo to Groups.io Mike - M0MLM
By Mike Millen · #21940 ·
Re: HP8656A Signal Generator
Thank you George. Ken?? M0KHW
By KEN WRIGHT · #27 ·
Re: HP 6012B volt zero and current regulation
I am using a fluke voltmeter to measure the current using the peak measurement, is that a reliable indication of regulation by voltmeter? I had an idea. If anyone has a 6012B, maybe 6012A, or a 6032A.
Re: HP 6012B volt zero and current regulation
I don't think you should equate brightness with current, as you have a non-linear device. I would personally be observing the current with a scope, not judging it by a lightbulb. A FET fed with a
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #25 ·
Re: HP 6012B volt zero and current regulation
The test results from the HP 6024 supply revealed that when the current is limited to 4 amps with the same setup from the 6012B, ramping up the voltage to test the current regulation it immediately
By DW · #24 ·
Re: HP 6012B volt zero and current regulation
I took a look at the testequipmenthq ( http://www.testequipmenthq.com/datasheets/Agilent-6012B-Datasheet.pdf ) for this supply, if I read correctly the regulation is within 10mA and 5mV, quite good. I
By DW · #23 ·
I forgot to say - you should all get an email when the transfer is complete
groups.io should email everyone when the transfer is complete. -- Dr David Kirkby Ph.D C.Eng MIET Kirkby Microwave Ltd Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, CHELMSFORD, Essex,
By Dr. David Kirkby <drkirkby@...> · #90635 ·
Re: HP 6012B volt zero and current regulation
[email protected]> wrote: Sure a lightbulb draws more current when cold, but if I understand the original poster correctly, he has set a current limit of 4 A on the PSU, so one would not expect to
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #22 ·
Re: HP 6012B volt zero and current regulation
NO This is the typical behaviour of a light bulb, 73 George G6HIG
By george edmonds · #21 ·
HP 6012B volt zero and current regulation
Hello, I had a account from yahoo groups agilent and I recently transferred over. I have a HP 6012B which I successfully repaired the current potentiometer so no more issue with the supply going full
By DW · #20 ·
Transfer from Yahoo to groups.io is now in the queue.
You may have seen this message on the Yahoo HP/Agilent list, but if not, I will put it here too. I have selected the "*Give Go Ahead to Transfer*" button with the following selected: * Transfer
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #19 ·
Latest update of transfer to groups.io - I have hit "Give Go Ahead to Transfer"
There does not appear to bern any messages coming through for several hours, so I thought it wise to start the copy to groups.io. I have selected the "Give Go Ahead to Transfer" button with the
By Dr. David Kirkby <drkirkby@...> · #90634 ·
HP 4145B Software Revisions
Anyone know the differences between the 4145B software revisions 1.0 and 1.2? Also, between revision 1.2 and 1.3? - George
By glkinst@... · #18 ·
Re: intro on groups.io
So far, so good.
By John Haskell · #17 ·
Re: intro on groups.io
Well, I made it here now too.? Daun
By Daun Yeagley · #16 ·