Re: Anybody got a good LCR meter that they want to sell?
On Sat, 15 Jul 2017, Bob Albert bob91343@... [hp_agilent_equipment] wrote: If you want something that measures actual values with good precision go buy DE-5000. Buy original one, from Japan. It
By Sergey Kubushyn · #84296 ·
Re: Anybody got a good LCR meter that they want to sell?
I wasn't comparing the units in detail.? For the vast majority of measurements, the cheaper one is more than adequate.? I am sure your extra money does buy some functionality but for me, I have
By Bob Albert <bob91343@...> · #84293 ·
Re: 141T reference replacement..a cure??
Below is a link to a Signalite application note pamphlet..Page 14 has the Z series of VR tubes. www.philbrickarchive.org/jlrmsousa/signalite_glow_lamps.pdf Bob
By Bob Goodrich <bobgoodrich84@...> · #84292 ·
Re: Anybody got a good LCR meter that they want to sell?
[hp_agilent_equipment] <hp_agilent_equipment@...> wrote: Are you saying that the Hungarian $55 one can be had on eBay for $10? I don't think so. The Hungarian one seems to be well thought
By Dr. David Kirkby (Kirkby Microwave Ltd) <drkirkby@...> · #84291 ·
Re: 141T reference replacement..a cure??
A number of my antiques use neon bulbs as voltage references; it seems to be common in HP (and other?) instruments of that era. I too have read about (and experienced) SA plug-in fuses blowing because
By Jeremy Nichols · #84290 ·
Re: 141T reference replacement..a cure??
My 141T has a Z82R7? reference tube in it.? As of 8/21/14 the voltage across the VR tube was measured at 83.6 instead of 82.7 V. I had to shunt R26? 22.1K with 220K in order to? in order to be
By Bob Goodrich <bobgoodrich84@...> · #84289 ·
Re: HP 8566B / 8568B bus interconnect cable
Donald,Have you opened the connectors and inspected the connections on the 60220 cable?? From my experience this cable should also work with you 8566B. -rastro
By rast tro · #84288 ·
Re: 141T reference replacement..a cure??
Ok, good question. This thread is nominally about the voltage reference in the 141T, older models, that was a gas regulator tube, that looked like an oversized NE2. It has been a very long time since
By Chuck Harris · #84287 ·
Re: ifr 2390 analyser
hi cliff second mail..10 ghz info......today have had over 50 mails for yahoo groups,,,,none to do with my request..so will mail them again tomorrow,,,to stop..... right 10 ghz ...GB3FY..located at
By Bob Ocallaghan <bob.g1epl@...> · #84286 ·
Re: Anybody got a good LCR meter that they want to sell?
Take a look here. I have had good luck with a couple of their testers. I bought this one but I bought it assembled but could not find that here. It is accurate and cheap etc.
By Dan W8KMX <w8kmx@...> · #84285 ·
Re: HP 8566B / 8568B bus interconnect cable
Verify your internal cable connections and contacts on both the cable end connectors and your instrument connectors. Over the years things take only so much abuse. I have had several units with both
By czelusniakd · #84284 ·
Re: Anybody got a good LCR meter that they want to sell?
That is a good unit for not too demanding applications.? However, it's available on ebay for a lot less money.? In some cases, less than $10 shipped. I have a similar one and use it a lot. Bob
By Bob Albert <bob91343@...> · #84283 ·
Re: Anybody got a good LCR meter that they want to sell?
There might be on here http://alfaradio.ca/Public_html/Consignment_test_equipment.pdf Mitch
By ssc <ssc@...> · #84282 ·
Re: HP 8566B / 8568B bus interconnect cable
The check instrument I red LED stays on after power-up and the display stays blank. After swapping the cables from one instrument to the other, I have found that the 60220 only works with my 8568B and
By Don · #84281 ·
Re: 141T reference replacement..a cure??
Hi Chuck, Without any disrespect or challenge intended¡­ How, sir, do you know these ionize around 87 volts? Thank you. Regards, Ken
By ken chalfant · #84280 ·
Re: 141T reference replacement..a cure??
They aren't NE2's. NE2's run at about 67V, these run at about 89V. -Chuck Harris Scott McGrath scott@... [hp_agilent_equipment] wrote:
By Chuck Harris · #84279 ·
Re: Replace Neon NE-2 with Zener in 141T PSU?
There are two phenomena going on here. The reason that there is a radioisotope inserted into "neon" references, is the neon strikes at a different voltage when exposed to light, vs dark. This is an
By Chuck Harris · #84278 ·
Re: 141T reference replacement..a cure??
Just visit Amazon 10 NE-2's for 8 bucks problem solved https://www.amazon.com/A3C-NE2-U-Bulbs-105-125-Terminals/dp/B00ZSPLRVS
By Scott McGrath · #84277 ·
Re: Anybody got a good LCR meter that they want to sell?
That's the one I meant. After some discussions I had with the author, I concluded seems pretty switched on about these. It is somewhat different in operation to the HP 4284A, in that the 4284A uses
By Dr. David Kirkby - Kirkby Microwave Ltd <drkirkby@...> · #84276 ·
Re: Anybody got a good LCR meter that they want to sell?
Maybe this will help. http://lcr.is-best.net/en/ "The price for one assembled and calibrated Hutale LCR-DDS-F 4.2 meter with a tested LCD display, plus a 4-wire silicon insulated measuring cables
By PAUL NICKALLS G8AQA · #84275 ·