CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: (OFF TOPIC) Manual request
[hp_agilent_equipment] <hp_agilent_equipment@...> wrote: Ah, my bad, one day maybe I'll learn to read to the end... The HP 3440A looks like a pretty cool instrument though :).
By
Sigur?ur ?sgeirsson
·
#83163
·
|
Re: HP6034 PSU Q1, 2 fet
Gents There is no argument that one has be very careful when working around HV circuits. 300+ DC rail falls into this category. Soooo, to address this I just ordered a ADP25 differential probe good to
By
KI6EZ
·
#83162
·
|
Re: HP 8648B and an off topic request.
Hi John Thank you for your suggestion, however, the fault in the 8648B is not in the RF portion but in the uP display/control circuitry which is totally different between the 8920A and the 8648B. I
By
george edmonds
·
#83161
·
|
Re: HP6034 PSU Q1, 2 fet
My comment was not made regarding the use of a scope, but, for safety when working on any circuity that is directly connected to the incoming mains/utility supply. It was not made to question your
By
george edmonds
·
#83160
·
|
Re: HP6034 PSU Q1, 2 fet
No, sorry it isn't. There are lots of strategies that will work just as safely. Using a pair of adequately rated 10x probes, and the ADD invert mode on your scope is one of them, and is precisely why
By
Chuck Harris
·
#83159
·
|
Re: HP6034 PSU Q1, 2 fet
Hi Chuck An isolation transformer is required equipment no just a good idea. 73 George G6HIG ________________________________________ Sent: 30 April 2017 02:18 To: hp_agilent_equipment@...
By
george edmonds
·
#83158
·
|
Re: HP/Agilent 8563E Spectrum Analyzer under Remote Control
Hi Tom, I have now read the Newest AN 150 and in particular a part to which you earlier referred (Thanks for that). Section was about Detector Types, and how that relates to the Data Dump. It's
By
bill.lauchlan171@...
·
#83157
·
|
Re: 3478A multimeter Spare display needed
No it doesnt seem to be. However one of the members here kindly offerd me one from his broken one. ---- 'Tom Miller' tmiller11147@... [hp_agilent_equipment] skrev ----
By
Magnus Arvidsson
·
#83156
·
|
(OFF TOPIC) Manual request
Siggi Thanks for the plug....But what Dave M is looking for is a BALLANTINE 3440A ( which we don't have) The one you saw was which we do have is an HP 3440A which would be more on topic :-) Dave I
By
Dave / NR1DX
·
#83155
·
|
Re: Manual request
Looks like Artek Manuals has it. See < http://artekmanuals.com/manuals/hp-manuals/>. [hp_agilent_equipment] <hp_agilent_equipment@...> wrote:
By
Sigur?ur ?sgeirsson
·
#83154
·
|
Repair rights
Forwarded from Tekscopes.
By
David C. Partridge
·
#83153
·
|
Re: HP6034 PSU Q1, 2 fet
That is typical of a problem where a full wave doubler is working half wave. This is one of those jobs where an isolation transformer is a good idea. You can get by without by using two probes, and
By
Chuck Harris
·
#83152
·
|
Re: HP 8648B and an off topic request.
George, Some of the boards in the 8648 are very similar to those in the 8920. The Component Level Information Packet Manual Part Number: 08920-90107, has schematics. It is (or was) on Keysight.com.
By
John Gord
·
#83151
·
|
Re: HP 8648B and an off topic request.
Hi Don I now understand your email, having looked at the available HP manual, I will probe around the display connector and the RPG connector. However I suspect that without component level
By
george edmonds
·
#83150
·
|
Re: HP8970A automatic Noise Gain meter
Hi Chuck, Thanks for your comments on this. I will seek for a suitable battery to replace it. Studying the RAM chip data sheet learns that the data retention threshold voltage is 2V . Therefore 2,8V
By
Herman van Rees
·
#83149
·
|
Re: HP6034 PSU Q1, 2 fet
Hi The DC voltage across the AC to DC stage storage capacitors will give a good indication of the health of the storage capacitors as you vary the output load. These capacitors must be high ripple
By
george edmonds
·
#83148
·
|
Re: HP 8648B and an off topic request.
Hi Thank you for your reply, I still do have WinXP sp3 machines, however, the 82357B adapter is not easily available in the UK. The only ones listed on a famous action site are from China and vary in
By
george edmonds
·
#83147
·
|
Re: HP6034 PSU Q1, 2 fet
Known good HP 6038A #1 Vout = 23.5Vdc Iout = 5.5Amps Input Filter out: Vdc = 317.5Vdc Vac = 1.48Vac (HP6034A = 12.2Vac!) #2 Vout = 23.5Vdc Iout = 9.5Amps Input Filter out: Vdc = 310.9Vdc Vac = 2.58Vac
By
KI6EZ
·
#83146
·
|
Re: HP 8648B and an off topic request.
Hi Don Thank you for replying to me, it is much appreciated. First I have never seen an extension card that would work with this generator, the three plug in modules use a 9 pin D for the power and
By
george edmonds
·
#83145
·
|
Re: HP 8648B and an off topic request.
I've successfully run the 8648 calibration and motherboard utilities on WinXP SP3 w/Agilent IO v16.x and 82357B USB GPIB adapter. No special hacks needed other than it only worked on a physical
By
Colby Burkett
·
#83144
·
|