CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: HP8407A Network Analyzer... opinions?
Hello John, Ok, thanks for the info!. What is in the 'accessory kit'? Could I get an 8505A for less than US$300??? Regards, JOSE ----------------------------------------------------------------------
By
Jose V. Gavila <eb5agv@...>
·
#5600
·
|
HP8407A Network Analyzer... opinions?
Hello! I have the chance to get a nice HP8601A + HP8407A setup. Please, could you comment about this set (performance, price, experiences, ...)? Thanks!!! Best regards, JOSE It's a pretty decent
By
J Forster <jfor@...>
·
#5598
·
|
HP8407A Network Analyzer... opinions?
Hello! I have the chance to get a nice HP8601A + HP8407A setup. Please, could you comment about this set (performance, price, experiences, ...)? Thanks!!! Best regards, JOSE
By
Jose V. Gavila <eb5agv@...>
·
#5597
·
|
Re: HP8568B CRT replacement question LCD?
Hi for the LCD CRT replacement kit take a look at the link below. Good but WAY TOO EXPENSIVE!!! http://cgi.ebay.co.uk/ws/eBayISAPI.dll?ViewItem&item=150079037839 Best regards Sotiris Pdmtr In
By
Sotiris
·
#5596
·
|
Re: YIG Source in HP-8505A Network Analyzer
08505-60227 OR 08505-60228 (REBUILT UNIT)
By
Dave-NR1DX/0 <nr1dx@...>
·
#5594
·
|
YIG Source in HP-8505A Network Analyzer
Hello, does anyone know the part number of the YIG module with the circuit designation of A2A19 and operating over the range of 4.21 to 5.51 GHz. Jim Barton
By
grossefeldberg
·
#5593
·
|
Re: HP8568B CRT replacement question LCD?
It was mentioned that there is an LCD replacement available for a tired CRT used in the 8568 and 8566 series. I use an external Tektronix X-Y-Z display which is OK but is there an LCD X-Y-Z device
By
k6yaz@...
·
#5595
·
|
Re: 141T storage failure
Chris I had the same problem ,12.6V on the flood gun pin - no obvious flood gun operation. It turned out to be the ground lead from the "cold" side of the flood gun ( pin 11, black wire )was not
By
rchrdpett
·
#5592
·
|
141T storage failure
I have a problem with my 141T/8555A spectrum analyzer. The gear works perfect in the conventional mode, but it will not store. When I push the "store" button, the screen simply goes blank. Pushing
By
Chris van Lint
·
#5591
·
|
Re: HP 1650A boot diskette
wrote: <http://www.home.agilent.com/agilent/techSupport.jspx?pid=1651A%3Aepsg%3\ I have these files but the disk is in a non-standard format and, anyway, I no longer have a floppy drive. I believe
By
va7dij <va7dij@...>
·
#5590
·
|
3586A SLM Error 3.1 AGAIN !
3586A, Options 003, 004 fitted with REV B ROMs After a major habitat move I unpacked and fired up my 3586A after a 12 month hibernation to do some tests (not having a Spec Analyzer) on some circuitry
By
hpxref
·
#5589
·
|
Free GPIB software for Prologix GPIB USB Interface
Hi folks, I am a newbie to this group. While I own a number of older HP devices this is not the reason why I enter this newsgroup. Instead, the people at Prologix told me that my EZGPIB utility that I
By
Ulrich Bangert <df6jb@...>
·
#5588
·
|
Re: HP8568B on screen text intensity - FIXED !!!
Don't feel bad, you learned something (we all did), the instrument is working and your wallet is not depleted, that's all that matters :-) A lot of these magnificent instruments do have CRT wear-out
By
Didier Juges <didier@...>
·
#5587
·
|
Re: HP8568B on screen text intensity - FIXED !!!
Well I feel pretty stupid as all it was was an adjustment! - the intensity limit pot (R516) was incorrectly set. It's not imeadiately obvious from the schematic but this POT has the effect of
By
David Woodhead
·
#5586
·
|
Re: HP8568B on screen text intensity
Chuck Harris wrote: There is a third fix: a company (I forgot whom, but they should not be too hard to google, or John Miles can post it here) makes a color LCD replacement for the entire display.
By
Didier Juges <didier@...>
·
#5585
·
|
Re: HP8568B on screen text intensity
Hi David, You have a low emission CRT. Most HP CRT's are on RF instruments where the operator feels inclined to leave the instrument on 24/7 to keep it warmed up and stable for use at a moment's
By
Chuck Harris
·
#5584
·
|
HP8568B on screen text intensity
I have 2 of these analyzers and both demonstrate exactly the same problem - the trace intensity becomes inreasingly less visible as the trace line lengths get shorter. On screen text, consisting of
By
David Woodhead
·
#5583
·
|
Looking for CPU board 54111D (later 2Gs/s version)
Looking to buy a CPU board (later version that supports 2Gs/s option in software). Anyone that can offer a working board at a reasonable price? I want to upgrade my unit with the 54114 test set and my
By
tunerwiz
·
#5582
·
|
Re: [TekScopes] Want to use a high-res voltmeter in the Portland Oregon area
Thanks Lars, but that instrument is only specified to 1% accuracy. I need one that's about 10000 times better. And so do you! Please, send further replies off-list to avoid crossposting. If I hear
By
Dave Wise
·
#5581
·
|
Want to use a high-res voltmeter in the Portland Oregon area
I have a couple of 5-1/2 digit differential voltmeters (Fluke 877A and 895A) in whose calibration I have lost confidence. Since (a) I don't have cubic dollars to spare and (b) it's Just A Hobby, a cal
By
Dave Wise
·
#5580
·
|