CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: HP8568B Display Intensity?
<david_woodhead@...> wrote: When I trace there Here's a little more info: The front panel command to intensify the graticule for photography works but all I see is the graticule. It completely dims
By
David Woodhead
·
#5408
·
|
First mixer for 8555A [141T Spectrum Analyzer System]
Hi Group, I`d like to obtain one first mixer for my new/old H/P 8555A plug - in for my 141T Spec/An. Does anyone have one that they don`t want? Ideally, I`d like a fully working one, but non - working
By
Don Collie <donmer@...>
·
#5407
·
|
HP8568B Display Intensity?
Just acquired an 8568B and have questions.... The graticule is a little out of focus and appears to be over intensified. The trace and on screen characters are very crisp. When I turn down the
By
David Woodhead
·
#5406
·
|
Re: Reseting 3325A
make shure that all the screws holding the pcb's are tighten, most of the grounds are closed thru the screws and the chasis.
By
elie_shvarzman
·
#5405
·
|
Re: Wanted: 8505A Network Analyzer Manuals...
Hi Mike, I have a paper set now. It is the other guy that needs a set. -Chuck Dr M J DiGirolamo wrote:
By
Chuck Harris
·
#5404
·
|
Reseting 3325A
Dear list members, I own a 3325A, a nice function generator, however it has an intermittent fault, it resets sometimes, usually it does that during warmup, but once in a while it also resets after a
By
pe1fbo
·
#5403
·
|
Re: Wanted: 8505A Network Analyzer Manuals...
Hi Chuck, I have a set on microfish. Do you have a reader? 73, Mike, W4XN -----------------
By
Mike D.
·
#5402
·
|
Re: Wanted: 8505A Network Analyzer Manuals...
Hi Glenn, Yes I did! I paid something over $350USD for a set of 8505A originals. They come in three, 3 inch, 3-ring binders, and about 50% of the pages are fold out schematics. Each binder is packed
By
Chuck Harris
·
#5401
·
|
Re: Wanted: 8505A Network Analyzer Manuals...
Hi Chuck, I just picked up an 8505A myself. Did you ever get a copy of the manuals for your analyzer? I'm looking for a set myself. -Glenn <cfharris@...> wrote:
By
glenn_briceno <glenn_briceno@...>
·
#5400
·
|
Re: HP SMPS MANUAL
Hi Anand, If you go to the Agilent website ( http://www.agilent.com ) and do a Search on "8924", you will see a download for the "8924C/E Assembly Level Repair Manual". On the left-hand side of Page
By
Matt Corbett
·
#5399
·
|
[Fwd: Re: Measuring frequency on a 50W transmitter]
wrote: the Tx to the cut a 100 in
By
didier_juges <didier@...>
·
#5398
·
|
Re: [Fwd: Re: Measuring frequency on a 50W transmitter]
Didier, this is fine providing that 1) the 5K resistor is at the T-piece end, and 2) from the non T-piece end of the 5K resistor, you put a ~50 ohm resistor from t
By
Geoff Blake <geoff@...>
·
#5397
·
|
[Fwd: Re: Measuring frequency on a 50W transmitter]
W???QFC wrote: Gene, Check http://www.ko4bb.com/Test_Equipment/Counter_Pickup.jpg It uses a common T BNC connector adapter, a short piece of coax cable with a BNC plug, a resistor and a BNC socket.
By
Didier Juges <didier@...>
·
#5396
·
|
HP SMPS MANUAL
Hi I am on the lookout for HP 0950-2952 Power supply Schematics. thanks in advance Anand
By
ANAND KP <anandkp63@...>
·
#5395
·
|
Re: 141T rear panel terminating plug wanted.
Thanks for the tip, Bernie!.................................Don.
By
Don Collie <donmer@...>
·
#5394
·
|
Re: 141T rear panel terminating plug wanted.
Check out http://www.glkinst.com/cables/hp_cables.htm This guy is excellent. Bernie
By
VE3FWF <ve3fwf@...>
·
#5393
·
|
141T rear panel terminating plug wanted.
Looking for one rear panel termination[s] plug, as used on the 141T mainframe. Thanking you,....................................Don Collie jnr.
By
Don Collie <donmer@...>
·
#5392
·
|
Re: Measuring frequency on a 50W transmitter
The counter's input stage, whose geometry has about 1/1000 the size and thermal mass of the fuse, will do a great job protecting the fuse. :) A pair of back-to-back Schottky diodes, perhaps the kind
By
John Miles <jmiles@...>
·
#5390
·
|
Re: Measuring frequency on a 50W transmitter
Most VHF/UHF frequency counters use a terminated 50 ohm input, usually rated at about 500 mW, and in this case, the fuse will provide protection, if you do something that you shouldn't have done. If
By
k6yaz@...
·
#5391
·
|
Measuring frequency on a 50W transmitter
Gene, there are several way to get it done. You could transmit into an antenna and put a second antenna on the counter, or you could get a 30 dB or higher power attenuator and place it between the
By
k6yaz@...
·
#5389
·
|