CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: 8558B centre frequency wildly unstable above 1250MHz
Be carefull with what you spray in. Some of those things conduct very good, resulting in a potentiometer that is not reacting anymore. I have just repaired a transcreiver where the former owner had
By
PA4TIM
·
#38430
·
|
Re: 8558B centre frequency wildly unstable above 1250MHz
I forgot to mention that it is important to glue the plastic tube to the nozzle otherwise the pressure will send the whole assembly including needle across the room. I used a plumbers PVC adhesive.
By
ferrymanr <g4bbh@...>
·
#38429
·
|
Re: HP 85662A Power supply issue help needed
Hi Guerrino, Congratulations for your finding! I had a similar problem in my HP-8672A. I bought it as 'unworking' at eBay... and, yes, it didn't work ;-). It is a very complex unit and I was afraid of
By
Jose V. Gavila <eb5agv@...>
·
#38428
·
|
Re: HP 85662A Power supply issue help needed
Hi Jose, the issue is found, the problem came from the RF section , there is a signal named HPON , normally this signal is 5V and is coming from the 5.2V power supply RF section , the signal was
By
tvcn17858@...
·
#38427
·
|
Re: FS 54701A Probes
Sold. Thanks to all who inquired.
By
mojoehand
·
#38426
·
|
Re: HP 204B Modifications.
<willcoele@...> wrote: I have encountered this also.
By
David DiGiacomo
·
#38425
·
|
HP 204B Modifications.
I have three 204B oscillators I'm restoring. One had a problem where C2 (the 3 section, 1% capacitor) had a shorted section. I replaced the shorted section with single 1%, .3uF. Close enough for the
By
[email protected] <willcoele@...>
·
#38424
·
|
Re: Are plotters still useful?
I've done the PIC version some years ago for an HP analog spectrum analyzer with X, Y and Pen Lift outputs. Worked reasonably well. The algorithm holds a do nothing loop waiting for the pen lift
By
Jack Smith
·
#38423
·
|
Re: Are plotters still useful?
It is still useful information! Thanks to all. I have a Velleman two channel digital scope that runs on the USB on a computer. It will do X-Y and I may try that for the units that have analog outputs.
By
rovmkr
·
#38422
·
|
Re: 8558B centre frequency wildly unstable above 1250MHz
Interesting and informational! Thanks, Greg
By
tcxo <tcxoe@...>
·
#38421
·
|
Re: 8558B centre frequency wildly unstable above 1250MHz
ferrymanr wrote: Me too! I recently "repaired" a Tek 7B53A and a Fluke 8600A with about $0.10 worth of contact cleaner generously applied to the switches. Both units were EBay "Parts - not working"
By
Bob Smither
·
#38420
·
|
HP3468A
Hello, I have an HP3468A that appears to have a bad control ROM. The unit just cycles between power up (lights up all elements on the display and a brief display of: OV.LD C:3111 and repeat. The
By
Bob Smither
·
#38419
·
|
Re: 8558B centre frequency wildly unstable above 1250MHz
I have a customised nozzle for my aerosol can of contact fluid. I still have the supplied 10cm length of tube but have fitted a hypodermic needle to the end. This allows me to get a little fluid into
By
ferrymanr <g4bbh@...>
·
#38418
·
|
Re: Question about Service Manual Copyrights
Most units did not come with complete service manuals. They had to be purchased separately. I believe HP has made all their old manuals public domain. Actually I believe they have been requesting any
By
Steve Vineyard <kj5rv@...>
·
#38417
·
|
Re: Question about Service Manual Copyrights
Agilent controls all copying and distribution of their manuals. They will license you if you contact them through the proper channels with certain stipulations as to what you can and can not
By
Artekmedia <manuals@...>
·
#38416
·
|
Question about Service Manual Copyrights
A simple question to anyone who may know: what are the legalities of copying HP service manuals? Some of them seem to be in the public domain, since they are offered on the HP information web site.
By
br4av01 <br4av01@...>
·
#38415
·
|
Re: Are plotters still useful?
I use a HP plotter to draw pcb layouts. I made an adapter from an old pen to hold a CD marker. It plots straight at the PCB and after plotting it is going in the stuff that solves the copper. I made a
By
PA4TIM
·
#38414
·
|
Re: Are plotters still useful?
So I looked up the 4815A and it does not have a screen. My reply below was only meant for instruments with a screen. Sorry To: "hp_agilent_equipment@..."
By
werner haussmann <w_haussmann@...>
·
#38413
·
|
Re: Are plotters still useful?
If the 4815A has the ability to dump the plotter sequence (HPGL) into a file you can create an image from that, or feed it to the Agilent Screen capture program to create the image for you. ? Look
By
werner haussmann <w_haussmann@...>
·
#38412
·
|
Re: Are plotters still useful?
For instruments that use an HPIB plotter, a Prologix USB-HPIB adapter and John Miles' 7470 program. Once the plot is in your computer you can then print it on any printer your computer works with, or
By
Jack Smith
·
#38411
·
|