Re: HP 54512B (pair) repair
Nope, Radu, a cable tie would require labor to install (“costs too much” in suit-speak). Cheaper to glue it down. I had a mechanical engineer coworker years ago with the nickname Elmer because
By Jim Ford · #150654 ·
Re: E5052A Power On Test (3.3V Bus Supply)
Unlikely to have been from a switching reg -- 1kHz is pretty low. Close-in spurs are often suppressed by some form of cancellation, and a little drift can cause the reappearance of spurs at around
By Tom Lee · #150653 ·
Re: HP 3403C True RMS Voltmeter display fault
Yes, Ed, I know exactly what you mean regarding the orange leadless tantalum caps. Sprague used to make them, and they told us that the orange material prevented them from printing the value,
By Jim Ford · #150652 ·
Re: E5052A Power On Test (3.3V Bus Supply)
70 MHz Surface Acoustic Wave (SAW) BPFs used to be common for satcom. 10 kHz is very narrow, though. I’m snickering a bit at the differences in spur performance in sig gens because I’ve seen
By Jim Ford · #150651 ·
Re: HP 54512B (pair) repair
Hi Radu, If you have a hot air desoldering station try to see if the heat will soften the glue/resin. Use low temp first and increase it slowly. Monitor the heat on the arm with an infrared
By Razvan Popescu · #150650 ·
Re: HP 54512B (pair) repair
Thank you, Mike. In terms of removing the arm from the switch stub (see pics enclosed a few messages down), where HP decided to use this brown resin to glue them together (completely unnecessary, in
By Radu Bogdan Dicher · #150649 ·
Re: HP8510C TRL Calibration
I put an 8510C driver into scikit-rf the other year that speaks the binary format and knows how to stitch sweeps, so if not it should be a quick code change especially if you already have PyVISA and
By jjoonathan · #150648 ·
Re: E5052A Power On Test (3.3V Bus Supply)
Hi Jim, thanks. I obtained the cal certificate for the other E5052A today. It was calibrated less than a year ago and this one shows an even lower noise floor.? It's a slightly newer unit and it has
By jmr · #150647 ·
Re: HP 3403C True RMS Voltmeter display fault
Hi AArnaud, Congratulations for the successful repair, and for having saved another valuable HP instrument from the scrap heap ! My conclusion is somewhat identical to my initial thoughts : start by
By Joel Setton · #150646 ·
Re: HP 3403C True RMS Voltmeter display fault
I recently had one destroy itself on an HP 16717a logic blade. Burned all of the way through the pcb, great fun. I guess that was early 90s vintage. Paul -- Paul Amaranth, GCIH |
By Paul Amaranth · #150645 ·
Re: HP 3403C True RMS Voltmeter display fault
I know what you mean Dave. I've seen soldery-looking stuff on some blown dipped Ta caps - the ones that haven't been burnt to a crisp. There is some solder in those too I think, for connection to the
By ed breya · #150644 ·
Re: HP8510C TRL Calibration
Out of curiosity, did you have any speed optimization enabled on your IEEE-488 interface? What software version was your 8510C running?
By Ed Marciniak · #150643 ·
Re: HP8510C CalKit file .CK_ format
Hi Calvin, Here is what I use for my HP8753D and 8720C, https://github.com/mankangustafsson/gpib_playground/blob/master/vna_calkit.py Basically I'm using GPIB to define a new calkit on the unit, then
By Marcus Gustafsson · #150642 ·
Re: HP 3403C True RMS Voltmeter display fault
I usually "replace like with like", or at least a modern equivalent. You should see all the problems that come up with people with no electronics knowledge on the vintage computing mailing lists
By Dave McGuire · #150641 ·
Re: HP 3403C True RMS Voltmeter display fault
On 3/3/25 12:41, ed breya wrote: > That's an interesting picture of the failed cap. I'd guess the molten blob on the can end is just some electrical solder that ended up there by coincidence sometime
By Dave McGuire · #150640 ·
Re: HP 3403C True RMS Voltmeter display fault
I forgot to comment on hermetic solid Ta caps. I have seen only a few failures of these over the years, and I consider them among the best of parts for reliability. I have seen lots and lots of
By ed breya · #150639 ·
Re: HP 3403C True RMS Voltmeter display fault
That's an interesting picture of the failed cap. I'd guess the molten blob on the can end is just some electrical solder that ended up there by coincidence sometime in the past, or maybe from inside
By ed breya · #150638 ·
Re: 3708A Noise and Interference Test Set - Looking for a Service Manual
Fantastic! That's exactly what I was looking for. Thanks a bunch, greatly appreciated! :) Regards, Jared
By Jared Cabot · #150637 ·
Re: HP 54512B (pair) repair
Radu, I wish you luck finding a replacement for the line filter and switch. Mike Sent: Monday, March 3, 2025 10:23 AM To: [email protected] Subject: Re:
By Michael Bafaro · #150636 ·
Re: HP 54512B (pair) repair
Mike, This is unrelated with the issues I'm having with the -12V rail. When disassembling/reassembling the scope, the EMI Filter (more specifically, its built-in switch) and the HP arm/button broke
By Radu Bogdan Dicher · #150635 ·