CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Thoughts on Hakko FR301
Hi,
I would not try to do this without the option to preheat the board to around 80C.
The problem is that it really hard to extract the 56pins in one go.
I my suggestion is to use ChipQuick on a
By
Rens Dijkshoorn | PA3AXA
·
#150450
·
|
Re: HP 8660B/86602B developed output stability problem, getting-started suggestion(s) request
TinySA Ultra used to check outputs from the 11707A (except for the two 11661B-related outputs, as I forgot to enable the "Ultra" mode for coverage > 800 MHz.
The 500, 100, 20 and 350-450 MHz signals
By
David Feldman
·
#150449
·
|
Re: Searching parts for HP 5370B
I can't help with the front panel frame, but I might be able to help with the filter.? I had to replace the one on my unit and ended up machining one out of 1/16" red acrylic and then using a vinyl
By
zgoode
·
#150448
·
|
Re: HP Agilent 8753ES VNA repair [Help]
Matt,
What do you see if you display the A, B, and R with MEAS/INPUT_PORTS? ?? (I assume menus are similar the the 8753D)
On my 8753D, the R channel is at about 0dB displayed (with some ripple) and
By
John Gord
·
#150447
·
|
Re: HP 8660B/86602B developed output stability problem, getting-started suggestion(s) request
Hi Ed, WB2UAQ ---
Thank you both for quick and helpful replies!
Ed - with your suggestion, I remembered that I do have a 11707A and it is now in the unit (I've never used it before as I've not had
By
David Feldman
·
#150446
·
|
Re: HP Agilent 8753ES VNA repair [Help]
Hi,
I did some tests on my working 8753ES.
These results could be used for comparison.
Yves
By
Yves Tardif
·
#150445
·
|
Re: 8596E Spectrum Analyzer Fault
Instead of START / STOP, try entering as CENTER and SPAN. ?Just to see if it freezes when it has enough info to start a sweep, or if it is related specifically to the sweep defined by entering the
By
Dave Wright
·
#150444
·
|
Re: HP 54512B (pair) repair
Awesome, thank you, Peter.
I wonder if anyone has a fresh recollection of what battery or maybe
battery-backed RAM would be suspect and possibly needed so I'd start
working on an order to have the
By
Radu Bogdan Dicher
·
#150443
·
|
Re: HP 54512B (pair) repair
Seems like you are on the right track.? Many HP scopes of that era lose their minds if the memory battery goes dead.
Peter
By
Peter Gottlieb
·
#150442
·
|
Re: Thoughts on Hakko FR301
And the likely price difference is worth paying in strides. I've said this
before - in full agreement with Dave McGuire - but there's no price that's
too high to get good, well working tools. The best
By
Radu Bogdan Dicher
·
#150441
·
|
Re: Thoughts on Hakko FR301
I think once one gets to use both kinds of units - "pistol" type like the
FR301, and "pen" type like an SX-80/90/100 by Pace, for instance - the
advantages become very clear.
I've converted friends to
By
Radu Bogdan Dicher
·
#150440
·
|
Re: Thoughts on Hakko FR301
Bought one a few years ago and wish I had bought it sooner.
It is really a fun tool to use, and having enough heat will not be a problem. I usually keep mine on the "2.5" setting or so, which
By
Keith Monahan
·
#150439
·
|
Re: HP 8660B/86602B developed output stability problem, getting-started suggestion(s) request
If you can locate an HP 11707A test plug in, it can be a bog help. It brings many of the signals out to the front of the unit for easy access.
Unfortunately I do not see any on EBAY...
By
Ed (scskits)
·
#150438
·
|
Re: Thoughts on Hakko FR301
The Hakko FR301 is the only desoldering gun I have direct experience with.? I bought one after years of just using wick, iron, and heat gun or all 3.? I was thoroughly impressed with how well it
By
Frank Mashockie
·
#150437
·
|
Re: Thoughts on Hakko FR301
Sergey,
I appreciate your input.
Yes there is a trailing power cord but in comparison to some other desoldering handpieces that have both a power cord and a vacuum line having only one item helps
By
Greg Muir
·
#150436
·
|
HP 54512B (pair) repair
Hi all,
Over the weekend I've got a couple of 54512Bs at my desk to seek to bring back to full functionality. My main scope is a 54522A, and I assume they have some commonalities, but I've yet to open
By
Radu Bogdan Dicher
·
#150435
·
|
Re: Thoughts on Hakko FR301
Mine doesn't jump at all when triggered.
-Dave
--
Dave McGuire, AK4HZ
New Kensington, PA
By
Dave McGuire
·
#150434
·
|
Re: Thoughts on Hakko FR301
On Tue, 25 Feb 2025, Greg Muir via groups.io wrote:
As of no trailing cables it is a misstatement. You STILL have a trailing
cable. It doesn't matter if it goes to a soldering station or to a
By
Sergey Kubushyn
·
#150433
·
|
Re: Thoughts on Hakko FR301
There's a trick if you can do it, for holes connected to ground planes (also works for those not).
You need two irons, one with a very fine tip, and one that is a conventional vacuum desolderer.
put
By
Harvey White
·
#150432
·
|
Re: Thoughts on Hakko FR301
That's a side effect of one of its biggest strengths: minimal vacuum hose length. The vacuum path from the tip to the pump is only a few inches, as compared to several feet for desoldering systems
By
Dave McGuire
·
#150431
·
|