CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
3577A multiple problems
Today I fired up my 3577A to begin to do some tests.? It has been sitting in my lab, fully environmentally controlled, for several years unpowered.? It was working perfectly when it was put away.
By
Peter Gottlieb
·
#148973
·
|
Re: HP 8593A Display repair
thank you for help. picture added. Am 13.12.2024 um 00:11 schrieb Yves Tardif via groups.io:
By
Martin M
·
#148972
·
|
HP8594E repair with "ADC-2V FAILL"
A friend sent me a failed HP8594E with the error message "ADC-2V FAILL" over the screen. I searched the network and most of the info tell me the power supply is failed. I opened the machine and saw
By
bv3ue
·
#148971
·
|
Re: 8751A Input Overload
That's interesting that yours is the same. Yes I also found if I reduced the source power slightly everything was OK. I have the IF bandwidth set at auto rather than 4khz I've not noticed this with
By
vee-dub565
·
#148970
·
|
Re: HP 8593A Display repair
Hi, When the Spectrum loses all its calibration constants, there is a chance that you will lose the synchronization of the display on the screen. You should try to do a "DEFAULT CAL DATA" and "CRT
By
Yves Tardif
·
#148969
·
|
Re: 8751A Input Overload
Same for me, starting at 5Hz at 0dBm, the message takes a few seconds and appears. But if I put the signal at -1dBm, the message does not appear. But I noticed at 0dBm, that if I put my filter at
By
Yves Tardif
·
#148968
·
|
Re: 8751A Input Overload
Done a bit more investigation. I found that it seems to be the bottom end of the sweep that causes an issue. With the sweep set at 10Hz - 500MHz it will sit there quite happily indefinitely, and
By
vee-dub565
·
#148967
·
|
Re: 8751A Input Overload
Hi, If you press ENTRY OFF, does the message disappear and appear again? I have an 8751A, and it works very well. If you connect Port#1 output directly to port R, by default, the RF output is at 0dBm,
By
Yves Tardif
·
#148966
·
|
8751A Input Overload
I just acquired an 8751A 5Hz to 500MHz network analyser. We have one of these at work and I thought I get my own to use for personal stuff. So I've set it up for a basic through measurement with a
By
vee-dub565
·
#148965
·
|
HP 8593A Display repair
I have a repair of HP8593A with the following problems: The PSU was fail. now complete recapping, it works. The lithium? battery was rip and the memory empty. Now it have a fresh battery, but the shp
By
Martin M
·
#148964
·
|
Re: HP 8341B with HP8410B VNA
I agree with Chuck - easy to change.? But you could also tke a look at the sweep output with a scope to determine if it is st for 1V/GHz or .5V/GHz. Cheers! Bruce
By
Bruce
·
#148963
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
Scott, thanks much for the info.? For my 8753ES can you or anyone else in this thread tell me if I want the reverse polarity cable (default) or the forward polarity cable for item No. 1?
By
Frank Mackowick
·
#148962
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
Slight correction regarding Vladan's comment: This is absolutely correct for the 8753ES, but not for the 8753E which has the same physically wider design as the 8753D.? The difference between the
By
Scott Vance
·
#148961
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
A lot of thanks for all that very useful compilation Vladan! Renaud
By
Renaud F5ZR
·
#148960
·
|
Re: HP 8566B issue above 18.5GHz ?
Hi Saevar, ( /g/HP-Agilent-Keysight-equipment/topic/109925844 ) You are right, it is definitely a problem with the analyzer. I am afraid to make any adjustments inside the device at
By
wojciechoo@...
·
#148959
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
My two Aliexpress "Gotek" drives came with latest release of the FlashFloppy fw. /Marcus
By
Marcus Gustafsson
·
#148958
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
For those who would like to replace a broken FD in the 8753ES, here is some information I found in my files. I have replaced several of the Teac floppy drives over the years. I found my notes, no
By
pianovt
·
#148957
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
Scott, it looks like you are correct. Here is a detail from one of the pictures in the ebay listing. V.
By
pianovt
·
#148956
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
Vladan, Evidently the SW on this SFR1M44-DU26 kind of sucks and may not work with some machines.? People online claim that something called Flashfloppy [ https://github.com/keirf/FlashFloppy/wiki/ ]
By
Scott Vance
·
#148955
·
|
Re: HP8753E, 8753D, 8753ES 3.5" disk drive replacement reference information
Scott, there is a chance that the ebay seller is making some firmware changes to the standard SFR1M44-DU26 GoTek emulator. Vladan
By
pianovt
·
#148954
·
|