CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Looking for Noise Source Driver Assembly E4401-60123 for E4407B Spectrum Analyzer
Dear All, I like to extend my Analyzer with the noise measurement option. Does somebody want to sell a E4401-60123 Board + Cables ? If yes please drop me a reply or send a pm. thanks for reading and
By
DL8EBL
·
#148820
·
|
Re: Troubleshooting a 8591e with opt 130
Marco, This is good news! Yves De : [email protected] <[email protected]> De la part de jansen.marco90 via groups.io Envoy¨¦ : 1 d¨¦cembre 2024 14:17 ? :
By
Yves Tardif
·
#148819
·
|
Re: Troubleshooting a 8591e with opt 130
Yves, Some good news, the spectrum analyzer is now passing self cal and conf test with a 300MHz marker at -20dBm at both Log and Lin setting. I was still poking around a bit, found some more (maybe
By
Marco
·
#148818
·
|
File Notifications
#file-notice
Scott Vance <scott_l_vance@...> added folder */HP & Agilent Firmware & Programs/HP 8753D Firmware/614* *Description:* HP8753D most recent firmware for older machines (6.14). --- The following
By
Group Notification <noreply@...>
·
#148817
·
|
Re: HP 8341B 1992 firmware version
I use an 8340A with SW rev 23 May 1985 with an 8510C with SW rev 7.16 - hope this data is helpful,? I have also used other 8340Bs with various SW revisions and never had any compatibility problems.
By
Bruce
·
#148816
·
|
Re: mailing lists, was Re: [HP-Agilent-Keysight-equipment] Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
<mcguire@...> wrote:
By
evan foss
·
#148814
·
|
Re: mailing lists, was Re: [HP-Agilent-Keysight-equipment] Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
While I generally agree, we would do well to bear in mind why those
By
Dave McGuire
·
#148813
·
|
Re: mailing lists, was Re: [HP-Agilent-Keysight-equipment] Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
[email protected]> wrote: True.
By
Dr. David Kirkby, Kirkby Microwave Ltd
·
#148812
·
|
8350A + 83525A mechanical issues
Hello In the last months I've been playing with a HP 8350A + 83525A that probably had a uncontrolled impact with something. After replacing a 7426 on CPU board and rebuilding most of the B.West
By
bumbo.chinelo@...
·
#148811
·
|
Re: VNA Resonance Methodology
jmr, I appreciate the offer, but it won't be necessary, thanks all the same. Now I know where I went wrong the dip is readily visible. I just need to take more care with my coil-winding technique in
By
Jinxie
·
#148810
·
|
Re: 83592B Plugin Repair - No RF Output - Need some measurements
Hi, have you read the thread " *Help request - how to test an HP8350B RF plugin YIG* " It was an unexpected problem in the PCB's sockets, check that too. John.
By
John Brokos
·
#148809
·
|
mailing lists, was Re: [HP-Agilent-Keysight-equipment] Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
Yes, pretty much. The first thing to remember is that mailing lists have nothing at all to do with the web, web servers, web sites, or web browsers. It's an email address that you send an email to (by
By
Dave McGuire
·
#148808
·
|
Re: Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
it might actually be better to eliminate this one, I already have a couple responses on the other posting I have, and nothing here, except for you letting me know you saw that I had put two listings
By
Dan
·
#148807
·
|
Re: Alignment of HP 412A after rebuild, having trouble with the first step.
I really appreciate it Richard. ?Nothing wrong with the meter, can mechanically zero it no problem with the small adjustment screw. Once the mechanical zero is that the meter is pretty much Dead on
By
Dan
·
#148806
·
|
Re: Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
Okay, I really appreciate it Dave. ?So what¡¯s the difference really? Do they kind of function the same, but each message and response puts an email in your email account? Thank you again, Dan
By
Dan
·
#148805
·
|
HP 8753B VNA - replace supercap on CPU A9 board with long-term primary battery?
I'd like to extend the power-off memory retention period of my HP 8753B from a week or two (it's original supercap) to "forever" (at least a very long time). Would it be possible to replace the
By
David Feldman
·
#148804
·
|
Re: Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
No problem. I saw the two messages in the moderator queue and it was pretty clear what happened, so I just put both through not knowing if you'd have a preference as to which one went. Keep in mind,
By
Dave McGuire
·
#148803
·
|
Re: Alignment of HP 412A after rebuild, having trouble with the first step.
Looked at the schematic, which I should have done before replying. R-126, the hum balance, is in the filament line. The 10 Hz signal is described as a beat note on the output of the DC amplifier. I
By
Richard Knoppow
·
#148802
·
|
Re: Alignment of HP 412A after rebuild, having trouble with the first step.
I have not worked on a 412 for many years. Is it possible the hum balance is NOT power supply hum but the residue of the chopper?
By
Richard Knoppow
·
#148801
·
|
Re: Trying to go through alignment procedure for HP412A that I rebuilt, having trouble with first step lol
I apologize, I have a duplicate thread. I didn¡¯t realized the post had to be authorized before being posted. It can be deleted, use this thread for help. Thank you, Dan
By
Dan
·
#148800
·
|