CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: HP 141T Power Supply Help Needed
I can't see what could destroy Q15, except perhaps C18 shorting. Dave Wise ________________________________ Sent: Wednesday, September 18, 2024 8:15 AM To: [email protected]
By
Dave Wise
·
#147197
·
|
Re: 8566B Attenuator Service
when a solution of HF penetrates the skin, from a splash for example... it dissociates into fluorine ions. those react with both calcium and magnesium ions, to significantly reduce their
By
Roy Thistle
·
#147196
·
|
Re: 8566B Attenuator Service
HF penetrates the skin, and dissociates, in body water, to form fluoride ions. Fluoride ions bond with both calcium and magnesium ions...reducing their availability in the body, for import muscle, and
By
Roy Thistle
·
#147195
·
|
Re: 8566B Attenuator Service
I'm sure your hardness scale figures are correct, Roy. But the particle size at 1500 grit is so tiny you'd need a microscope to spot them. So hardness is only part of it in this context.
By
Jinxie
·
#147194
·
|
Re: 8566B Attenuator Service
Dimethyl mercury is one of the worst compounds IME. Even if you were protective gloves, it can't save you from a single drop of the stuff. This unfortunately lady became the poster girl for
By
Jinxie
·
#147193
·
|
Re: 8566B Attenuator Service
Stuff people used to have around the house, could dissolve glass.
By
Roy Thistle
·
#147192
·
|
Re: 8566B Attenuator Service
Aluminum Oxide...hardness of about 9 on the Mohs hardness scale...glass, hardness of around 5-6. Silicon carbide... even harder.
By
Roy Thistle
·
#147191
·
|
Re: GPIB scripting software?
Thank you very much. I will give it a try. Cheers! H
By
Harke Smits
·
#147190
·
|
Re: Introduction
Nice shop !!! The 8902 is the best !! Ing. Patricio A. Greco Taller Aeron¨¢utico de Reparaci¨®n 1B-349 Organizaci¨®n de Mantenimiento Aeron¨¢utico de la Defensa OMAD-001 Laboratorio de Calibraci¨®n
By
Patricio A. Greco
·
#147189
·
|
Re: HP 141T Power Supply Help Needed
I don't have a HV probe currently, but its on my shopping list. I'm going to go with 0v at the moment though, given the state of Q15. I guess I'm just wondering if I should expect other damage to have
By
Bill Berzinskas
·
#147188
·
|
Re: Introduction
Jim, Nice lab! I sent a picture of your lab to my daughter in Santa Clarita and she wants to know where you worked in the LA area (we assume). I have a similar lab as I worked for Motorola in
By
Michael Bafaro
·
#147187
·
|
Re: HP 141T Power Supply Help Needed
Bill, Q15 is the FET that is in the HV regulator circuit. The gate to the other leads will read open if the ohm meter is connected to back bias the junction. The question is what voltage is present at
By
Michael Bafaro
·
#147186
·
|
Re: Introduction
I agree. My typical layout is similar - a radial (90/45/0/-45/-90) distribution of shelving and tall carts that are all within easy reach (3'-6') of any project. Due to the projects as the picture was
By
Radu Bogdan Dicher
·
#147185
·
|
Re: HP 141T Power Supply Help Needed
Checking things out last night in the LV side of the HV supply, I saw on the edge of Q15 a small delamination. Very tough to see in that tight space but just enough to warrant further investigation. I
By
Bill Berzinskas
·
#147184
·
|
Re: Introduction
A neet and compact layout. I had some equipment to shop carts after running out of roo on my bench. That made it easier to take to the Ca lab as well. [email protected]> wrote:
By
Michael A. Terrell
·
#147183
·
|
Re: Introduction
Fine, I'll bite. Only visible is the left side of the active part of my bench - pic from a few weeks ago, with the projects then, as I'm too comfortable in my living room arm chair right now (where
By
Radu Bogdan Dicher
·
#147182
·
|
Re: Introduction
Welcome! Since it seems the thing to share lab pictures:
By
Harold Foster
·
#147181
·
|
Re: KO4BB manuals site error
Now same here in Italy. The whole site works except the "Manuals"
By
maurit
·
#147180
·
|
Re: 8566B Attenuator Service
Hi, In my memories, as someone who graduated as an EE in microelectronics technologies, arsenic is probably the most benign stuff you'll find at a fab. I still remember one occasion, when we had a
By
Szabolcs Szigeti
·
#147179
·
|
Re: 8566B Attenuator Service
HF is a calcium seeker. The official treatment is calcium gluconate gel. If you do get suspected skin contact flushing with milk is a first aid alternative. Surprisingly some rust stain removers sold
By
Robert G8RPI
·
#147178
·
|