Date
Re: HP 3852A firmware update issue
On 5/5/24 13:40, Maciej Kawalkowski, Liberty Electronics Design and Service LLC wrote: > I did follow the? instructions on www.dalton.ax <http://www.dalton.ax> and that seems to be the issue.?? I
By Dave McGuire · #144113 ·
Re: HP 8405A Vector Voltmeter Probes
Just be aware that the -281x series is rated for 20V, so you get a reduced capacitance at the expense of a reduced voltage rating for the probe. The BAT62 that Dave Wise mentioned has a lower
By Tom Lee · #144112 ·
Re: HP 8405A Vector Voltmeter Probes
It would certainly be nice to use HP glass diodes for the repair and I only have to find two of them :) I think the capacitance of the classic 70V 5082-2800 will be too high. Also, I've already got a
By jmr · #144111 ·
Re: HP 8405A Vector Voltmeter Probes
The old Philips (NXP) 1PS70 diode looks quite good on the datasheet. The IV curve isn't quite the same as the 8405A but I think it will have similar capacitance when reverse biased and the dynamic
By jmr · #144110 ·
Re: HP 8405A Vector Voltmeter Probes
Many years ago, I repaired a lot of 3406A and 8405A to 1 GHz operation. I used 5082-2800 series diodes. I had matched quads from HP at that time for some of the repairs, and matched diodes for others.
By Jeff Kruth · #144109 ·
Re: HP 8405A Vector Voltmeter Probes
I've just done some basic 1 port tests of the 1N6263 and the 8405A probe diode in various forward and reverse bias conditions and the 8405A is clearly a different diode to the 1N6263. The capacitance
By jmr · #144108 ·
Re: Parts needed
I think you want these https://www.mouser.com/ProductDetail/EDAC/305-030-520-202?qs=U4pz39agNJAeH5Ar2TraIg%3D%3D --------------- 305-030-520-202 ---------------
By Maciej Kawalkowski · #144107 ·
Re: Parts needed
I was at the electronics store but they did not have any 30 position ones. A lot of other ones were available.
By Maciej Kawalkowski · #144106 ·
Re: General microwave switch type 1699 details needed
I thnk Ed meant, schematics and info for the HP product it was used in.? (The HP8720B) That should tell you what is needed to use it correctly. Nothing like a little reverse engineering from a good
By Dave_G0WBX · #144105 ·
Re: Parts needed
@ Maciej Kawalkowski ( /g/HP-Agilent-Keysight-equipment/message/144093 ) Thank you for this information. I see these are available in the Mouser catalogue.
By Christopher Tucker · #144104 ·
Re: Parts needed
The Cinch number you provided does match those on the motherboard. The ones on eBay do look like the originals. What would be the difference between the '301' of these and the '341' of the
By Christopher Tucker · #144103 ·
Re: Parts needed
The closest match I have found is an EDAC 307-015-521-102, given the spacing and pitch. However, it is only one set of contacts. I checked their catalogue and they do not make one with a set of two
By Christopher Tucker · #144102 ·
Re: HP manuals
Sorry, this is the correct link to use at first: https://www.simonsdialogs.com/manuals/ Hal
By Harold Foster · #144101 ·
Re: 11048C feed through termination data?
And though only the help of my own, I have found the HP data on the 11048x 50ohm and 11094x 75ohm feed through terminators. Link to uploaded scan of the data as supplied with these terminators
By Jared Cabot · #144100 ·
Re: General microwave switch type 1699 details needed
Info in this link: https://www.eevblog.com/forum/repair/hp-8720c-vna-s2-s3-20ghz-microwave-switch-control-voltages/
By Harold Foster · #144099 ·
Re: HP 8405A Vector Voltmeter Probes
I've just completed the curve tracer comparison of the HP8405A diode against the 1N6263 diode. The diodes are quite similar, but the HP8405A diode shows much lower dynamic resistance when biased
By jmr · #144098 ·
Re: General microwave switch type 1699 details needed
Hello to the group. I downloaded the service manual on the unit. Quite a nice unit. However its also at the point that HP stopped including schematics. So the manual is of no use. Not even sure it had
By paulswed · #144097 ·
Re: HP 8405A Vector Voltmeter Probes
I've been told I can have the 8405A meter, so I can now start examining the B probe more closely. It may be that something else is damaged in it and this is causing the poor frequency response and
By jmr · #144096 ·
Re: Agt N5230A-220 Need help
If you have not already done so, I would recommend replacing the coin cell battery on the CPU board and then shorting the reset pins on this board.? Not sure if this will solve your problem, but it
By Scott Vance · #144095 ·
Re: Parts needed
The original appears to be made by Cinch: NSN 5935-00-236-7955: 1251-1886 Keysight Technologies, Inc. 252-15-30-341 Cinch Connectors, Inc. SCM15D/7-4HP Interconnection Products