CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: 5086-7337 *Yig Oscillator issue*
Hi from an earlier posting there might be confusion PCB stands for printed circuit board But RPG is a new one for me are you referring to the plug in Key pad ? As far as I can remember there is not a
By
Paul Bicknell
·
#133299
·
|
Re: 5086-7337 *Yig Oscillator issue*
No CCT Dues NOT stand for calibration constants CCT Stands for Circuit Diagram in the old days HP included them in the Service manual later on they were sold separately as CLIPS component level
By
Paul Bicknell
·
#133298
·
|
Re: 5086-7337 *Yig Oscillator issue*
Hello again: I assume that 'CCT' stands for calibration constants. I haven't that table. As I told you, I have only the OSM available on Keysight site, which is the same in the files section here.
By
RubenRubio
·
#133297
·
|
Re: 5086-7337 *Yig Oscillator issue*
Absolutely yes! I have been there on this issue. Even a brand new one from the factory may not give an output, or a very low output until it is aligned with the proper endpoint drive voltages. Don
By
Don Bitters
·
#133296
·
|
Re: 8566B attenuator fix
Comparing the older electromechanical attenuators with the newer circuit card attenuators, I saw several failures on the circuit card. I never saw a schematic for the card and could not pry the info
By
Don Bitters
·
#133295
·
|
Re: 8566B attenuator fix
The 2 push rods on each attenuator/solenoid assembly have ball and notch rings under the ball that fits into a keyhole slot on the contact flap. The key to disengaging the push rod from the flap is
By
Don Bitters
·
#133294
·
|
Re: HP 8595E SA DB-25 RS232 is not functioning.
Your full-handshake hookup is correct, although it is missing the analyzer DTR to pc DSR (paralleled with pc CTS), but since you are configuring for no-handshake, it may not matter. You say the
By
k1ggi
·
#133293
·
|
Re: HP 8595E SA DB-25 RS232 is not functioning.
You can try the loopback handshaking cable if the interface can work without needing handshake: https://en.wikipedia.org/wiki/Null_modem Ozan
By
Ozan
·
#133292
·
|
HP 8595E SA DB-25 RS232 is not functioning.
Hi all, I want to connect my HP 8595E to my PC using the only available port it has, RS232 via a DB-25 connecter (option 023). As i couldn't find out the correct pinout i managed to make a quick
By
candrian
·
#133291
·
|
Firmware for HP 54200D
Hi all. Sorry it has been a while since I have been on here - life, you know, can get in the way of fun sometimes. Anyway, I have been feeling sorry for this puppy for a while and finally bought it to
By
medasaro
·
#133290
·
|
Re: 8566B attenuator fix
It¡¯s pulse drive. There are MM74HC123 dual monostable multivibrators doing the pulsing and the ULN2003A provides the high current drive off of those pulses. I have an issue with some of this on mine
By
bagojfalvibagoj@...
·
#133289
·
|
Re: 8566B attenuator fix
Don - I did not see any of the leaf switches (which interrupt the current after switching) in this attenuator - do they rely on a current limit to protect the coil or is the drive a pulse ? Did I
By
Bruce
·
#133288
·
|
Re: 8566B attenuator fix
The attenuator drive is on A16 brd. in the RF section. It is a current drive to the solenoids in the attenuator. The attenuator is 10dB, 20dBa, 20dBb, 20dBc sections. The attenuator steps are: 0dB =
By
Don Bitters
·
#133287
·
|
Re: 8490XX step attenuator mating connector
Hello JF , It is used on the driver cord 11764-60004 ( but I don't have the parts list of this cord... ) 73s Eric
By
f1ghb
·
#133286
·
|
Re: 8490XX step attenuator mating connector
It looks like IDC - should be easy to find. Cheers@! Bruce Quoting "jfphp via groups.io" <jfphp@...>:
By
Bruce
·
#133285
·
|
Re: 8490XX step attenuator mating connector
I think that is an IDC header connector 10 pin with 2.54mm pitch. Can you measure the distance between pins?
By
Razvan Popescu
·
#133284
·
|
Re: 8490XX step attenuator mating connector
It is rectangular. The Viking connector is for the 4/18 Ghz green old attenuators or the driver box 11713A On Monday, March 13, 2023, 06:30:33 PM GMT+1, Bruce <bruce@...> wrote: Viking ????
By
jfphp
·
#133283
·
|
Re: 8490XX step attenuator mating connector
Viking ??? If it is round, it is probably Viking Quoting "jfphp via groups.io" <jfphp@...>:
By
Bruce
·
#133282
·
|
Re: Tracking Generator Board 5062-8282 CLIP
I have a CLIP for the 5062-8232 LODA control, and the 5063-0635 Tracking generator control. They are both part of the 8590E-L-CLIP scan that I purchased from Artek media. Talk to them I'm sure they
By
Dave Wright
·
#133281
·
|
HP 85865B Signal Monitoring Software for HP 8566B, 8567A, 8568B, 71000 Modular Series, and 8562A Portable
Hello all, I am new here and this will be my first post. I discovered the beauty of HP meters a few years ago. Since then I have built up a collection. I want to control my devices via HP-IB and I use
By
Rudolf BoscoLab
·
#133280
·
|