CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Does an HP Transformer Specification Document exist ?
Photo of the hp 9100-1415 Transformer ( small open frame unit on the Left side ):
By
gren
·
#132763
·
|
Re: strange issue on Agilent 54641D MSO
If I had to guess I would say bad contact at some point. I haven¡¯t pulled the schematic to see what the front end looks like but I¡¯m thinking something loose. It only does it on channel 1 correct,
By
KB2LMN
·
#132762
·
|
Re: Does an HP Transformer Specification Document exist ?
hi Clay, I am looking for specifications on the HV transformer? hp 9100-1415 ,? used in the hp 9100a Calculator ( ca. 1968 ), that powers its electrostatic CRT display ( hp 5083-1551 ). It would be
By
gren
·
#132761
·
|
Re: HP 8662A A2 Slots
The best description of the 8662/8663 power supply deficiencies that I¡¯ve seen is this YouTube video: https://youtu.be/9O8EQTKV5rI. The original power supply design is really, really poor and a
By
Blue Smoke Lee
·
#132760
·
|
Re: HP 8662A A2 Slots
The serial # would be on the label at lower right, the one that's been obliterated. Somebody reeeeally didn't want that serial # to be known. AFAIK it isn't recorded anywhere else. It doesn't seem to
By
John Miles
·
#132759
·
|
Re: HP 8662A A2 Slots
Is there a definitive document that details about the mods to the A2 boards and which ones should be present Also is the 8662a serial number in software available on the device
By
colingoode2000
·
#132758
·
|
Re: HP 8662A A2 Slots
I haven¡¯t tried powering yet as there is a fault label on the front for the psu I Plan to remove all psu boards and test / replace caps etc before powering ? I can¡¯t find the serial number or may
By
colingoode2000
·
#132757
·
|
Re: HP 8565A Spectrum Analyzer Noisy
Video filter has some effect but not big. Furthermore, both the noisy and the clean traces have the video filters set at the OFF position.
By
Pax Electronica
·
#132756
·
|
Re: Advice on how to use an SA for test point troubleshooting
Chuck - Gotta agree with the mind reading comment. Thanks! What I suspect is the "test point" is probably a connection between circuit elements (amp, splitter, modulator,etc.) and they specified the
By
Bruce
·
#132755
·
|
Re: Advice on how to use an SA for test point troubleshooting
Hi Bruce, I agree, but the person specifying that you look at that point needs to define how. And, I am pretty sure they did... if one looks. Reading minds is a perilous task when you are up to your
By
Chuck Harris
·
#132754
·
|
Re: Does an HP Transformer Specification Document exist ?
I have wondered the same thing about HP transformers over the years.? HP In Loveland, Colorado for years had a separate facility we referred to as the Components Building.? They wound transformers
By
freshndaire
·
#132753
·
|
Re: Advice on how to use an SA for test point troubleshooting
Hi Tony Just looking at your post and the excellent advice given I think there are a few pointers I can give you as I strongly advise you invest in the following I use DC blocks on my spectrum
By
Paul Bicknell
·
#132752
·
|
Re: HP 8662A A2 Slots
Er, not EEPROMs, but EPROMs, probably 2732s or 2764s. -- john, KE5FX Sent: Sunday, February 19, 2023 12:16 PM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment]
By
John Miles
·
#132751
·
|
Re: HP 8662A A2 Slots
Yeah, that's an updated CPU board with a lithium battery. Not super common, but a good upgrade from the original design that put NiCds next to the most expensive/delicate RF hardware. The older 8662As
By
John Miles
·
#132750
·
|
Re: strange issue on Agilent 54641D MSO
It has been doing it for like 2 months or so. No abuse or measurement that triggered it (at least not something I recall, it has not been used much lately) Wilko
By
Wilko Bulte
·
#132749
·
|
Re: Hot air soldering tool
Another vote for the Quick 861DW - I've had one for a few years, it's always performs very well, no matter if you're trying to reflow a couple surface mount resistors with the air turned way down, or
By
Andrew Hakman
·
#132748
·
|
Re: Advice on how to use an SA for test point troubleshooting
You may also use a differential probe, it is important to pay attention to the probe's input impedance and the common mode rejection ratio (CMRR) of the probe and oscilloscope. The input impedance of
By
KB2LMN
·
#132747
·
|
Re: Advice on how to use an SA for test point troubleshooting
One type of probe that could be used for this purpose is a passive probe with a bandwidth of at least 500 MHz and a maximum input voltage that exceeds +2 dBm. A passive probe is typically less
By
KB2LMN
·
#132746
·
|
Re: 5086-7337 *Yig Oscillator issue*
Yup, you got point :) I¡¯ll search a resistor to apply that method, ohm law at it¡¯s best. Regards, Ruben
By
RubenRubio
·
#132745
·
|
Re: Advice on how to use an SA for test point troubleshooting
Both SAs and Scopes measure voltage. If a signal level is CORRECTLY specified in dBm, the impedance must be 50 ohms unless otherwise stated. All that is necessary to do is the mathematical conversion
By
Bruce
·