CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Dead 54720D
Do you have the list of gpib to dump? the FW? ? i can try this
By
boddax@...
·
#122409
·
|
Re: HP-8753E Option Key Installation Failure
Rich, There is nothing wrong with just reading the contents of the EEPROM. Then store the original safely and program another one for a test. I¡¯ve done that a couple of time for spectrum analyers.
By
Harke Smits
·
#122408
·
|
Re: HP-8753E Option Key Installation Failure
Leon: That is good information. In a little while, I am going to test my S400 Jumper to make sure when I toggle #8 on the dip switch, I am getting continuity. The idea of having to pull the EEPROM and
By
Rich Miller
·
#122407
·
|
Re: HP-8753E Option Key Installation Failure
Hi Rich, I've done an option upgrade 14 days ago on my 8753D (with the CPU 000 board, which is probably also in your VNA). I've got the same error, because I did not flip the jumper (there is no A9
By
LeonP
·
#122406
·
|
Re: Help E4402B 1DR Option not working
Funny you should raise this as I was just yesterday trying to get my E4401 with the same option to less than 1KHz to try and have a look at the spectral purity of a 8640B.?It would not go below 1KHz
By
Dave Ireland
·
#122405
·
|
Re: Help E4402B 1DR Option not working
Hi Contact me off group. Hardy Fra: [email protected] [mailto:[email protected]] P? vegne af Francesco Ledda via groups.io Sendt: 12. februar 2022 02:01
By
hardyhansendk
·
#122404
·
|
Re: Help E4402B 1DR Option not working
Have you checked this? https://edadocs.software.keysight.com/kkbopen/how-do-i-upgrade-my-esa-e-series-spectrum-analyzer-589310374.html Maybe you need to update the firmware or something? You could try
By
Mark Bielman
·
#122403
·
|
Re: HP-8753E Option Key Installation Failure
Hi Andrew: Yes, I am not sure what is going on. I was told this usually is a pretty straight forward process. The analyzer is not failing any of the self test. I think tomorrow I am going to measure
By
Rich Miller
·
#122402
·
|
Re: 11710B Down converter
you may be able to cross it over to a PN2218A.?? Some 2N numbers in a T0 style can cross over to an epoxy package by replacing the 2N with a PN. Harvey
By
Harvey White
·
#122401
·
|
11710B Down converter
My down converter is something i use a lot with my 8640B sig gen when I? need a signal below 450 KHZ.? Unfortunately a clumsy accident killed the output.? The failure was traced to Q1 and Q2 on the
By
Willie
·
#122400
·
|
Re: HP-8753E Option Key Installation Failure
If the serial numbers match, and you still get the fail message, I wonder if that indicates there's actually a hardware problem with your analyser and it can't complete the self-cal properly. These
By
Andrew Hakman
·
#122399
·
|
Help E4402B 1DR Option not working
I have an E4402B that shows options 1DR installed, but it doesn't seem to work as no BW smaller than 1 kHz can be selected. See picture. What can I do to address this issue? Thank you and Best,
By
Francesco Ledda
·
#122398
·
|
Re: HP-8753E Option Key Installation Failure
Hi Andrew: This is the procedure I used: https://www.keysight.com/us/en/assets/9018-40043/installation-guides/9018-40043.pdf It looks to be identical to what you and anther poster has given me within
By
Rich Miller
·
#122397
·
|
Re: HP-8753E Option Key Installation Failure
From the service manual on page 3-5 A9 Switch Positions 1. Remove the power line cord from the analyzer. 2. Set the analyzer on its side. 3. Remove the two lower-rear comer bumpers from the bottom of
By
Andrew Hakman
·
#122396
·
|
Re: 8566 5.2V supply
A bit of a late reply, but I hope it is still of value. The 1854-0441 was used as Q4 on the A17 boards for instruments with serial number prefixes in the range 2410A to 2532A. It is a general purpose
By
benj3867
·
#122395
·
|
Re: HP-8753E Option Key Installation Failure
I believe there's a jumper or a dip switch that has to be set correctly to allow the eeprom to be written. The instructions are in the service manual. [email protected]> wrote:
By
Andrew Hakman
·
#122394
·
|
HP-8753E Option Key Installation Failure
All: I posted about this over at the EEVBLOG, but I figured I should post it here too. I am having a problem loading the Harmonic and Time Domain Options (OPT2 & OPT10) for my HP-8753E. I have a
By
Rich Miller
·
#122393
·
|
Re: [HP-Agilent-KI eysight-equipment] FM Tuner alignment generator?..
The 8640 can deviate 10.7 if you mix it down with e.g. the 11710 Down Converter. Or even any generator and a mixer; there¡¯s an app note for that, AN171-2. Dave Wise Sent: Thursday, February 10, 2022
By
Dave Wise
·
#122392
·
|
Re: 54717A Calibrator
I am interested in this calibrator plug in as well. I have three of these wonderful scopes, and one needs to be recal. Best, Francesco K5URG
By
Francesco Ledda
·
#122391
·
|
Re: FM Tuner alignment generator?..
To do a comprehensive job of aligning FM tuners you really want a generator designed for that job - especially if you want to verify or align FM stereo multiplex decoders. One example of a relatively
By
nj902
·
#122390
·
|