CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: HP-8753E Option Key Installation Failure
If the serial numbers match, and you still get the fail message, I wonder if that indicates there's actually a hardware problem with your analyser and it can't complete the self-cal properly. These
By
Andrew Hakman
·
#122399
·
|
Help E4402B 1DR Option not working
I have an E4402B that shows options 1DR installed, but it doesn't seem to work as no BW smaller than 1 kHz can be selected. See picture. What can I do to address this issue? Thank you and Best,
By
Francesco Ledda
·
#122398
·
|
Re: HP-8753E Option Key Installation Failure
Hi Andrew: This is the procedure I used: https://www.keysight.com/us/en/assets/9018-40043/installation-guides/9018-40043.pdf It looks to be identical to what you and anther poster has given me within
By
Rich Miller
·
#122397
·
|
Re: HP-8753E Option Key Installation Failure
From the service manual on page 3-5 A9 Switch Positions 1. Remove the power line cord from the analyzer. 2. Set the analyzer on its side. 3. Remove the two lower-rear comer bumpers from the bottom of
By
Andrew Hakman
·
#122396
·
|
Re: 8566 5.2V supply
A bit of a late reply, but I hope it is still of value. The 1854-0441 was used as Q4 on the A17 boards for instruments with serial number prefixes in the range 2410A to 2532A. It is a general purpose
By
benj3867
·
#122395
·
|
Re: HP-8753E Option Key Installation Failure
I believe there's a jumper or a dip switch that has to be set correctly to allow the eeprom to be written. The instructions are in the service manual. [email protected]> wrote:
By
Andrew Hakman
·
#122394
·
|
HP-8753E Option Key Installation Failure
All: I posted about this over at the EEVBLOG, but I figured I should post it here too. I am having a problem loading the Harmonic and Time Domain Options (OPT2 & OPT10) for my HP-8753E. I have a
By
Rich Miller
·
#122393
·
|
Re: [HP-Agilent-KI eysight-equipment] FM Tuner alignment generator?..
The 8640 can deviate 10.7 if you mix it down with e.g. the 11710 Down Converter. Or even any generator and a mixer; there¡¯s an app note for that, AN171-2. Dave Wise Sent: Thursday, February 10, 2022
By
Dave Wise
·
#122392
·
|
Re: 54717A Calibrator
I am interested in this calibrator plug in as well. I have three of these wonderful scopes, and one needs to be recal. Best, Francesco K5URG
By
Francesco Ledda
·
#122391
·
|
Re: FM Tuner alignment generator?..
To do a comprehensive job of aligning FM tuners you really want a generator designed for that job - especially if you want to verify or align FM stereo multiplex decoders. One example of a relatively
By
nj902
·
#122390
·
|
Re: FM Tuner alignment generator?..
Hi, Recently I was using my 8645A for tuner alignment (a Mcintsh MR71 tube tune). I tried all sorts of methods - the 8645 can sweep the FM range with an FM modulated signal on top of it. Finally, for
By
Martin
·
#122389
·
|
Re: 54717A Calibrator
Here the best i can do , i dont have pro tools https://postimg.cc/MX9MrCRp https://postimg.cc/DWC3KPcL front and rear
By
boddax@...
·
#122388
·
|
Re: 8560E Second Converter
Hi Dave limits needs to be accurate as the level is used in doublers too low does not work. best regards Peter ________________________________ Fra: [email protected]
By
Peter Hansen
·
#122387
·
|
Re: 8640B - No Count
Brian Hope yours is as easy to fix as my loaner unit. Traced the internal and external count through the counter chain (was worried the ECL chips had failed but they are all good) up to the counters
By
Dave Ireland
·
#122386
·
|
Re: 8560E Second Converter
Peter The first fault was U700 and the series pass transistor on U700 supply that was gone. Replaced that and all the alarms cleared. The 600MHz is still a bit low but comparing the device 600MHz and
By
Dave Ireland
·
#122385
·
|
Re: 8560E Second Converter
Wow a bit ordinary for HP. I am loaning one of those nano spec an that proports to go to 4.4GHz and check the LO and the output of the 1st mixer. Then I will go back in and have a closer look at all
By
Dave Ireland
·
#122384
·
|
Re: 8560E Second Converter
Hi, Just for completeness I will share a couple of pictures of the second converter in a 8563A that I fixed. In the first picture, it was not easy to see the issue: [image: 20180207_223009_s.jpg] I
By
Askild
·
#122383
·
|
Re: 8560E Second Converter
Hello in 90% cases of that failure your U501 in A15 is dead. It is a 18-19dBm MMIC . Not critical use ERA5 or MSA0586 etc. also if your 300Mhz Cal output is bad it that failure. They look ok still if
By
Peter Hansen
·
#122382
·
|
Re: [HP-Agilent-KI eysight-equipment] FM Tuner alignment generator?..
Hi Bruce, Although I've used the 8640 for FM alignment on occasion -- with great results -- I wouldn't want to have to use it on a regular basis. The FM modulator doesn't support a large enough
By
Tom Lee
·
#122381
·
|
Re: FM Tuner alignment generator?..
Unless you've got your heart set on spending a lot of money, there are several pieces of non-HP equipment that should do the task just fine: the NanoVNA and the tinySA.? Both about the size of a deck
By
Jim Allyn - N7JA
·
#122380
·
|