¿ªÔÆÌåÓý

Date
Re: HP/Agilent/Keysight version of Tek Wiki?
I'd rather not modify that, as then it will go away when I update the software. There's already a mention of it on the Contribution Guidelines page. That's a default behavior of DokuWiki. I've
By Dave McGuire · #121569 ·
Re: HP/Agilent/Keysight version of Tek Wiki?
Shouldn't have any problem from people who read the guidelines but I expect some people may disregard that. Maybe add a reminder on the Upload page ? Unrelated: why do MHz and GHz suffixes show up
By Chris B · #121568 ·
Re: HP 89410A / 89441A internal 3 1/2 floppy replacement
Hi, I own an 89441A, and I too am one of the people interested in your floppy disk replacement project. I have already experimented with a GOTEK on an old PC running MS-DOS6.21, Win98SE and XP and it
By Yves Tardif · #121567 ·
Re: HP/Agilent/Keysight version of Tek Wiki?
Oh yeah. I *hate* that! I have a whole mess of datasheets on my web site, but I refuse to upload any with that sort of nonsense in there... I call 'em "branded", as in what they used to do with
By Roy J. Tellason, Sr. · #121566 ·
Re: hp 5340A frequency counter missing oscillator
Hello Christopher, Checking the spare parts - I've such a HP10544A Oscillator (working condition). For further details (i.e. shipping) may you contact me via pm, please? Best regards, Stephan -- Your
By Dr.-Ing. Stephan Massner · #121565 ·
hp 5340A frequency counter missing oscillator
All, I bought an hp 5340A counter due to be thrown away that when I received it, had its oscillator pirated. It seems it (A18) and 05340-60089 (A3) have been removed. Would anyone have these parts so
By Christopher Tucker · #121564 ·
Re: New member (with a dso-x 3012a not booting)
Hi Tommy don't worry, do nothing more! Close the oscilloscope and read all the topic that they suggested to you or: "DSOX2000 and 3000 series - license, have anyone tried to hack that scope?" Always
By maurit · #121563 ·
Re: HP 89410A / 89441A internal 3 1/2 floppy replacement
Hi Mike, Great news, I for one would be interested in details of your solution. Peter
By Peter Brown · #121562 ·
Re: HP/Agilent/Keysight version of Tek Wiki?
You're welcome, HaHa! I've created/updated a bunch (20-something) of pages in the past week or so. I'm probably 'done' for the moment - just 4 more units that I could maybe add, but they're in the
By saipan59 (Pete) · #121561 ·
Vintage Boonton stuff for sale
I have two Q meters (HF and VHF) and an RX meter for sale in Los Angeles.? Boat anchors, expensive to ship. All in excellent condition with original or copy manuals.? Everything works. The Q meters
By Bob Albert <bob91343@...> · #121560 ·
Re: HP/Agilent/Keysight version of Tek Wiki?
Yes, there has been a huge flurry of activity since it was discussed here recently. That's been really nice to see. Yeah, I have a 4195A too, I thought about it for a minute last summer and decided
By Dave McGuire · #121559 ·
FS HP4194A Operators & Service manuals
The Op manual is an HP original printing, the Service manual is a repro with a CD of the schematics in pdf. The binder in the Op manual has broken away from the outer cover. See pictures $15 for both,
By Charlie · #121558 ·
FS HP 3455A Operators & Sevice manuals
Both are original HP printing, in one binder. $15 plus USPS Media Mail
By Charlie · #121557 ·
Re: HP/Agilent/Keysight version of Tek Wiki?
Cool, a lot of new content on hpwiki since the last time I visited. I added the 3478a and 8643a pages but didn't get to the 4195 which I find a bit daunting. Plus, there's no VNA category yet. Is
By Chris B · #121556 ·
Re: HP 8663A Keycode Stimulus Diagnostic
I'm not familiar with the 8663A, but I did have a problem once on my 8780A where the keypad didn't respond.? The problem turned out to be a broken copper leaf spring underneath the "8" key.? The key
By Matt Corbett · #121555 ·
Re: New member (with a dso-x 3012a not booting)
Appreciate your help! So, I tried booting the scope from a 12V bench supply. Unfortunately no joy... The thing draws about 2 Amps while doing nothing, is that reasonable (label says 100W on back
By Tommy · #121554 ·
Re: New member (with a dso-x 3012a not booting)
Not necessarily a sleep mode. When the on-off-switch does not cut mains power completely it means the unit is not off but in a standby-mode where some electronics are always active. cheers Martin
By Martin · #121553 ·
Re: New member (with a dso-x 3012a not booting)
Update to newer firmware if you can get the scope to boot. You're experiencing NAND corruption which can occur with older firmware. The update will remap the bad blocks(if possible) and provide better
By Steve Draper · #121552 ·
Re: New member (with a dso-x 3012a not booting)
Thanks for the suggestion but no sleep mode I'm aware of.
By Tommy · #121551 ·
Re: New member (with a dso-x 3012a not booting)
Scope was powered off.
By Tommy · #121550 ·