¿ªÔÆÌåÓý

Date
Re: I'm old 70+, the 70K system is old; good or bad omen?
Yeh, Dan it losing step...back at it... Sent from my T-Mobile 5G Device Get Outlook for Android<https://aka.ms/AAb9ysg> ________________________________ Sent: Tuesday, November 23, 2021 8:17:55 AM To:
By Gene Silvernail · #120418 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
"Surely you could've taken it further last night.? Sleep is for the weak! ;)"To quote a character from one of (IIRC) Friedrich Duerrenmatt's short stories, "Schlafen ist Suende!" - sleep is a sin!?
By Jim Ford · #120417 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
That's a good start. Apparently! No, 7 capacitors. They are not dual capacitors; they simply have three leads. See the datasheet for Sprague (now Vishay) 672D. Surely you could've taken it further
By Dave McGuire · #120416 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
No burnt smell...no over amping any traces...all clean, a plus! Faraday has left the building!... None of the dual lead caps below are any where there spec...all running just a few uF even at 120 Hz.
By Gene Silvernail · #120415 ·
Re: BASIC on the HP 3396B Integrator II ?
O.K., the missing ROM was found by a fellow HP fan and a copy has been installed in my device. I now see that the core model has a BASIC interpreter built-in, but not the interactive BASIC system
By Martin Hepperle · #120414 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
Right-Oh DC > AC > DC I'm kind of like my dog... Sniff > Visual > Locate... bury the bone
By Gene Silvernail · #120413 ·
Re: : HP Spectrumanalyzer 851b and 852a
Hi Michael, did you check the addendums / change notes section of your manual already? These instruments obviously underwent a lot of changes in the beginning. For the 851A alone, I have a 1/2" stack
By ChrisBeee · #120412 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
"Human senses first"...take a look at where the leads exit those capacitors, look for some light charring or darkening around the leads. Target those first. Yes, something caused that fuse to blow.
By Dave McGuire · #120411 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
Dave that's spot on my next move. I need to get a schematic to work from rather than going in blind. I have a ESR meter that can read with some considerations ESR, etc in-circuit. I will make readings
By Gene Silvernail · #120410 ·
Re: Looking for a 16534a or 16533a oscilloscope card
Nada on a 33A or 34A from me.
By Precaud · #120409 ·
Re: Maybe someone can use parts for a HP3577A?
Hi Wilko, I purchased the keyboard (therefore no longer in the ad), which contains 51 Bill West switches. It proved in very good condition and it was packed with great care. I hope others will be
By Raymond Domp Frank · #120408 ·
Maybe someone can use parts for a HP3577A?
Just stumbled on this advert. Mind you, I am not the seller nor do I know him. Prices are in € and the parts are in the Netherlands.
By Wilko Bulte · #120407 ·
Re: 5065A rubidium frequency standard, no 2nd harmonic.
Jared You can pull it from the front or back. They come from the same circuit. Your simply looking to see if teh 5 MHz is off in open loop mode. If its more then 1 Hz I will believe thats trouble. You
By paulswed · #120406 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
Got that Dave... makes sense and availability is probably nil... will replace with 2 leg varieties...TNX Gene/K7QHO Sent from my T-Mobile 5G Device Get Outlook for Android<https://aka.ms/AAb9ysg>
By Gene Silvernail · #120405 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
I don't recall whether the third lead is isolated or not, but I replace them with two-leaded capacitors. As far as I can tell, that was just HP being overly anal-retentive about immobilization of the
By Dave McGuire · #120404 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
Thanks Dave, What's the story on the dual caps? Regards Gene Sent from my T-Mobile 5G Device Get Outlook for Android<https://aka.ms/AAb9ysg> ________________________________ Sent: Monday, November 22,
By Gene Silvernail · #120403 ·
Re: I'm old 70+, the 70K system is old; good or bad omen?
Here is a Mouser list I use: Mfr.: KEMET Mfr. #: A759MU277M1VAAE022 Mouser #: 80-A759MU277M1VAAE22 Desc.: Aluminum Organic Polymer Capacitors 35V 270uF 20% ESR=22mOhms RoHS Compliant 20 20 Ships Now
By tmillermdems <tmiller11147@...> · #120402 ·
Re: 5065A rubidium frequency standard, no 2nd harmonic.
Not sure of the circuit - I would pull it from a place you are sure drives the Ghz synthesizer - OXO mist likely Quoting "Jared Cabot via groups.io" <jaredcabot@...>:
By Bruce · #120401 ·
Re: 5065A rubidium frequency standard, no 2nd harmonic.
I have the Leo Bodnar GPS standard to compare against, should I pull the 5MHz from the front or rear panel of the 5065A, or directly from the OCXO module?
By Jared Cabot · #120400 ·
Re: Looking for a 16534a or 16533a oscilloscope card
I too have a '532A that I'd like to re-home for a nominal sum, if anyone is interested. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By Dave McGuire · #120399 ·