¿ªÔÆÌåÓý

Date
Re: HP200CD oscillator
EL86 and 6CW5 are exact equivalents ¨C they are just two different numbering systems (American vs European I think). And they are readily available on eBay for around $10 or so including
By Sharp, David · #119731 ·
Re: HP200CD oscillator
Purple pink is likely caused by the excess gas in the tube ionizing.? Unless it's a mercury vapor tube (don't think it's likely), soot and burn marks (not a getter flash) is not a good thing to
By Harvey White · #119730 ·
Re: Re-capping an HP-130 Scopes
Evidently the markings on capacitors may not always be correct. Interesting video from Mr. Carlson¡¯s Lab. https://youtu.be/BnR_DLd1PDI George
By Glydeck · #119729 ·
Re: HP 3245A Universal Source
Alan? Thanks for your thoughts on this problem. I had found the excellent article on xDevs in the past , but I have now downloaded it again as its been enhanced. I had not checked if Keysight wold
By phill.r1@... · #119728 ·
Re: HP200CD oscillator
gassy tube no good.
By Dave R <daverickmers@...> · #119727 ·
Re: Does anyone have an Agilent 16452A Liquid Test Fixture?
Hi, Can you determine how the electrodes are fixed into the outer case? I understand that there's one electrode on each side. The electrodes must be electrically isolated from the main body, so I
By Dr. David Kirkby, Kirkby Microwave Ltd · #119726 ·
Re: HP200CD oscillator
I would have thought so if they are alternative valves (the casing is marked for both?) You¡¯ll probably need to recalibrate after that but it ought to make it work a little better
By nigel adams · #119725 ·
Re: HP200CD oscillator
Thanks Nigel, can I mix an EL86 and 6CW5 in the one unit ?
By Richard Merifield · #119724 ·
Re: HP200CD oscillator
Think you can count the one on the left of the image as failed ¨C looks like it is arcing internally. Suggest you try a replacement first. Regards Nigel Sent: 27 October 2021 12:54 To:
By nigel adams · #119723 ·
Re: HP200CD oscillator
Actually it rises to about -50V when I let things warm up. I am thinking it may be one of the EL86 tubes. I was assuming warmth meant it was probably glowing but now I have taken the shields off I
By Richard Merifield · #119722 ·
Re: Re-capping an HP-130 Scopes
Outside foil connection may be even more important in scopes and other test gear because of often lower signal levels being measured, and the scope containing sweep and power supply circuits that
By greenboxmaven · #119721 ·
Re: HP4271B test fixture
*Thank you all for the info,* I will order one since building one would cost as much and I would not have as nice a case....HA I repaired my 4271B I bought for $20 at a hamfest and all it really
By Wallace Gasiewicz · #119720 ·
Re: HP200CD oscillator
I get < -1V across R40... A bit less than the -200V expected :)
By Richard Merifield · #119719 ·
Re: Agilent/Keysigh ESG series CLIP
Hi Xu OK about when you joined I believe the issues regarding the Copy right issues with HP was dealt with before I and most changed to this group IO in 2005 from the previews group ( I believe
By Paul Bicknell · #119718 ·
Re: Re-capping an HP-130 Scopes
From: byterock@... <mailto:byterock@...?subject=Re:%20Re-capping%20an%20HP-130%20Scopes> Date: Tue, 26 Oct 2021 10:56:58 PDT Just a general general questions on replacing the paper
By Dave_G0WBX · #119717 ·
Re: HP4271B test fixture
All of the knock-off fixtures I've tried have the same BNC spacing as the HPs. Dave Casey [email protected]> wrote:
By Dave Casey · #119716 ·
Re: HP4271B test fixture
I think the bnc spacing was common across the range of instruments to allow maximum flexibility/use of the test heads - looks the same on my 4275 and 4192 we have at work. Regards Nigel Sent from my
By nigel adams · #119715 ·
Re: HP4271B test fixture
Would hope the BNC spacing is the same. Probably is. These are good from DC to 13Mhz and up to 42VDC per the manufacturer. Regards Tony
By tgerbic · #119714 ·
Re: Agilent/Keysigh ESG series CLIP
Corrections: The 2019 date was when I OCR'd and bookmarked the files. The purchase date was in 2018 and the files were scanned in 2011. -Xu
By Xu Wang · #119713 ·
Re: Agilent/Keysigh ESG series CLIP
Thanks, Paul, for the background information. I joined the Yahoo group in 2009, so I wouldn't know about what happend 15 years ago in the group. The topic has been brought up a couple of times in