CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Weather resistant, covered Litz wire wanted.
Depending on the frequency, PVC's loss tangent will ruin your loop Q, so try to use HDPE or LDPE instead. Possible source of litz wire can be transformers used in high efficiency SMPS's, but the ideal
By
Andy ZL3AG
·
#111984
·
|
Can capacitors
Greetings, From time to time I see that someone is working to repair or restore an instrument with the old multi capacitor metal can components and that appears to be a never ending struggle. The
By
ken chalfant
·
#111983
·
|
Re: Weather resistant, covered Litz wire wanted.
Very interesting Daniel.? The US transmitter at Cutler, Maine? uses similar Litz wire, but runs three of them in parallel to keep the losses down!Great pictures. Ed W2EMN
By
Edward Newman
·
#111982
·
|
Re: Weather resistant, covered Litz wire wanted.
Hi Donald, I think this one would have fulfill your need. composed of 18000 enamelled coper wires but it is rather heavy: 5 kg per meter and more than 8 cm in diameter. My hand gives the scale for one
By
Daniel Artaud F6BRD
·
#111981
·
|
Re: 8590B low sensitivity problem...
I probably don't know what I'm talking about, but... I had similar symptoms with my Tektronix 494AP, where it would not complete the sorta self calibrate. Turned out the sensitivity was about 20 dB
By
Burt K6OQK
·
#111980
·
|
8412A and 1710A boards/parts
Anyone have a need for boards or parts for an 8412A phase magnitude display or a 1710A oscilloscope?? I broke these down to assemblies/boards about 10 years ago as the devices had mechanical damage.
By
tgerbic
·
#111979
·
|
Re: HP8505A focus (or ghosting)
gassy jug Sent: Friday, December 04, 2020 4:05 PM To: [email protected] Subject: [HP-Agilent-Keysight-equipment] HP8505A focus (or ghosting) I get a focus or ghosting issue with
By
Mike Vande Voort
·
#111978
·
|
HP8505A focus (or ghosting)
I get a focus or ghosting issue with the display on my HP8505A network analyser. I can 'go through' focus but it doesn't get really sharp at all. The picture below is a little deceptive in that it
By
vk2bea
·
#111977
·
|
Re: Weather resistant, covered Litz wire wanted.
Hi Rainer. I`m planning a 10 turn square loop, with turns spaced an inch or so to get the self resonant frequency to be as high as possible. Each side will be 2meters or so long, so I`ll need 2 x 4 x
By
donald collie
·
#111976
·
|
Re: Weather resistant, covered Litz wire wanted.
Scientific Wire Company https://www.scientificwire.com/ I expect they will export if you are not in the UK. You can buy online. -- Dr. David Kirkby, Kirkby Microwave Ltd,
By
Dr. David Kirkby, Kirkby Microwave Ltd
·
#111975
·
|
Re: Weather resistant, covered Litz wire wanted.
Cute..forgot pix
By
jim
·
#111974
·
|
Re: Weather resistant, covered Litz wire wanted.
Built this ...used a "hula hoop" from the toy store, aluminum foil for shield, 4 conductor "telephone" wire for conductor (multiple turns) ...FWIW? (not an open frame type tho) Jim
By
jim
·
#111973
·
|
Re: Repairing flat high voltage ribbon used in HP displays
On 2020-12-04 6:13 a.m., Joel Setton wrote: > Hello, > > Yes, this is a delicate repair, indeed. Replacing the complete ribbon > cable, assuming you could get one, does not look like an option,
By
Toby
·
#111972
·
|
Re: Weather resistant, covered Litz wire wanted.
I am puzzled as to why you want litz wire. Litz wire was used many for winding low or medium frequency receiver coils such as IF coils. At some frequency it no longer has any advantage over plain
By
Richard Knoppow
·
#111971
·
|
Re: Weather resistant, covered Litz wire wanted.
By
doug
·
#111970
·
|
8590B low sensitivity problem
Having repaired the PSU and overcome my issue with corrupt NVRAM, I'm now trying to run the self calibration routines. The frequency routines run OK, but the amplitude routines fail very quickly.
By
Martin Whybrow
·
#111969
·
|
Re: Repairing flat high voltage ribbon used in HP displays
Hi Joel, Thanks again for more info. Yes. I'm pretty sure that's the case. I am definitely trying to avoid complete CRT removal from the 1331A.
By
Toby
·
#111968
·
|
Re: Repairing flat high voltage ribbon used in HP displays
Hello, Yes, this is a delicate repair, indeed. Replacing the complete ribbon cable, assuming you could get one, does not look like an option, because the other end of the cable is somehow bonded to
By
Joel Setton
·
#111967
·
|
Re: Weather resistant, covered Litz wire wanted.
Hi Donald, how many meters do you need ? I have AWG24/19 FEP 73, Rainer Am 04.12.2020 um 01:21 schrieb donald collie:
By
DF6NA Rainer
·
#111966
·
|
Re: Weather resistant, covered Litz wire wanted.
Thanks for the suggestion George - there`s plenty of cotton covered stuff on eBay [bless em]...................Don C.
By
donald collie
·
#111965
·
|