CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: 4195A question
Yup, definitely interested. It's a lot of stuff and I'm spread a bit too thin. -Dave
By
Dave McGuire
·
#104751
·
|
Re: 4195A question
I'll be doing that too; I have quite a lot of that hardware. I still have to get things set up, get RMB loaded, etc. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By
Dave McGuire
·
#104750
·
|
Re: 4195A question
I could also verify the software for anything requiring HP 9000 / 300 computers Quoting Dave McGuire <mcguire@...>:
By
Bruce
·
#104749
·
|
Re: 4195A question
Put me on the list to notify as you get to them. I could help if you are interested in help. Cheers! Quoting Dave McGuire <mcguire@...>:
By
Bruce
·
#104748
·
|
Re: HP 334A Balance Pots
I've had pretty good luck prying open variable resistors, but you have to be very careful about breaking off the tabs. Only bend them out as much as is absolutely necessary, and if possible, try to
By
Dave McGuire
·
#104747
·
|
Re: 5343A troubles
Have you done a very thorough inspection of the input connector and checked it for any play (looseness)? If loose then check the cable connection on the inside of the input connector for any hardline
By
Don Bitters
·
#104746
·
|
Re: HP 334A Balance Pots
Poor choice of cleaning chemicals often results in a bad day. Cleaning chemicals that were formulated specifically for this application tend to be a lot more expensive than those that were not, but we
By
Dave McGuire
·
#104745
·
|
Re: HP 334A Balance Pots
I may try prying them open as well so as to be a bit more careful about how I'm cleaning things in there. Thanks, Barry - N4BUQ
By
n4buq
·
#104744
·
|
Re: HP 334A Balance Pots
I'd considered doing that as well but I've read horror-stories where some "cleaners" have dissolved the carbon track rather unexpectedly. Thanks, Barry - N4BUQ
By
n4buq
·
#104743
·
|
Re: 4195A question
On that note, I have calibration and verification software for many, many different instruments that I got from a calibration house that shut down. It will be awhile before I will be able to image the
By
Dave McGuire
·
#104742
·
|
Re: HP 334A Balance Pots
I wondered about doing something similar and have experienced what you're describing as well. Even though they're W-W, I also wondered if a ten-turn pot would work well and may give it a try (outside
By
n4buq
·
#104741
·
|
Re: 4195A question
Tobias - I'd like to correspond off line about how you did the translation. I'd like to do the same for the 8340 and some other equipment I have. As I said, I have an 9000/300 system and a good hpib
By
Bruce
·
#104740
·
|
Re: HP 334A Balance Pots
?My 332A's COARSE pot did not respond adequately to cleaning. I replaced it. I do not like concentric controls in this application - it's too easy for FINE motion to nudge COARSE slightly. I drilled a
By
Dave Wise
·
#104739
·
|
Re: 4195A question
I would really like to get a copy of both the original version and your reimplementation, if you're willing to share them. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By
Dave McGuire
·
#104738
·
|
Re: 4195A question
Excellent, I have a Prologix adapter, use it all the time. I'd welcome a copy of your PY prog. You can privately email me: hp at quackers dot net. Again, thanks.
By
Bill E
·
#104737
·
|
Re: 4195A question
Would you be willing to share the software (both versions)? I'm building an HP 9000/300 system and a GPIB analyzer as a platform to translate HP verification SW to more modern languages. This would be
By
Bruce
·
#104736
·
|
Re: 4195A question
Bill, I have the cal. software ( HP BASIC). As you said, it needs a lot of specific HP gear, but I re-wrote it in Python so it can be run on a modern PC with Prologix GPIB USB adaptors. And it is
By
Tobias Pluess
·
#104735
·
|
Re: Racks for older equipment
Yes, the "real" ones for restaurant use are NSF-rated and very, very sturdy. With lots of restaurants unfortunately going tits-up nowadays due to covid19 shutdowns, there will be a flood of commercial
By
Dave McGuire
·
#104734
·
|
Re: HP 334A Balance Pots
I have had some luck by prying the covers off for cleaning and then crimping the tabs back. Can't be done where the pots are stacked. AB were the best of the bunch are a pain to clean. Ohmite sold
By
Richard Knoppow
·
#104733
·
|
Re: 5343A troubles
On 4/10/20 1:48 PM, Daniel Sheen wrote: > I have a rather bizarre problem with a 5343A counter. Observed symptoms > are that the high frequency input works reliably up to about 250MHz, > reads garbage
By
Dave McGuire
·
#104732
·
|